You are here: Foswiki>Software Web>TCSSWReportFile_090101 (06 Oct 2009, NormCushing)Edit Attach
********************************************************************************************************
    TCS Software Performance Report
 
    Observing Night:   Jan 1 2009 to Jan 2 2009
 
    Reporting period beginning:   Thu Jan  1 16:54:01.368 2009
    Reporting period ending:      Fri Jan  2 07:52:58.427 2009
********************************************************************************************************
             - Command event statistics that are without a percentage value
               were calculated by ignoring command events that "failed".
 
         *** - Three (3) asterisks preceded events only have the first 25 occurances
               of the event listed in the "Events of Interest" sections.
 
    SEQERROR - This keyword means a command event is missing its "started" or "complete"/"failed" peer event.
 
    SXDXBOTH - This keyword means a sided subsystem left/right/both conflict has occurred.
********************************************************************************************************
    Events with a Priority value that is out of range. Priority will be changed to a value of "Warning".
      event = MCS.MCSPU.HydrostaticBearing.HBS_on_sucessful,  priority = 0, 2
      event = gcs.command.stopGuiding.triggered,  priority = 0, 2
      event = pcs.telescope.command.listPMTerms.started,  priority = 0, 2
      event = pcs.telescope.command.listPMTerms.complete,  priority = 0, 2
**********************************************************
IIF GUI Command Event Activity                                     
      Nothing to report

IIF GUI Single Event Activity                                      
      Nothing to report

IIF GUI Events of Interest
      Nothing to report
**********************************************************
IIF Startup and Shutdown Activity                                  
      Nothing to report

IIF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.authorize. . . . . . . . . . . . . . . . . . . . . . .    0.02    0.02    0.01    0.10   100.0 %         32         32                      
                                                                       0.02    0.02    0.01    0.10
     command.getTrajectory. . . . . . . . . . . . . . . . . . . . .    0.21    0.46    0.12    3.34   100.0 %        747        747                      
                                                                       0.21    0.46    0.12    3.34
     command.moveFocus. . . . . . . . . . . . . . . . . . . . . . .    4.55    5.44    0.21   36.29    98.6 %        732        722         10           
                                                                       4.54    5.51    2.19   36.29
     command.offset . . . . . . . . . . . . . . . . . . . . . . . .    6.54    8.76    0.00   33.98   100.0 %         98         98                      
                                                                       6.49    8.94    2.46   33.98
     command.preset.(TRACK) . . . . . . . . . . . . . . . . . . . .   59.43   54.06    6.60  197.50    96.8 %         31         29          1          1
                                                                      59.79   55.69    8.37  197.50
     command.sendWavefront. . . . . . . . . . . . . . . . . . . . .    1.93    3.69    0.37   16.77   100.0 %        915        915                      
                                                                       1.93    3.69    0.37   16.77
     command.stepFocus. . . . . . . . . . . . . . . . . . . . . . .    1.77    4.12    2.19    6.60   100.0 %        269        269                      
                                                                       1.77    4.12    2.19    6.60

IIF Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     noneMode . . . . . . . . . . . . . . . . . . . . . . . . . . .                             4

IIF Events of Interest

   1  FAILED    IIF        command.moveFocus                                             Thu Jan  1 18:26:33.603 2009  to  Thu Jan  1 18:26:33.869 2009   (  0.27) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus failure for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus failure for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

   2  FAILED    IIF        command.moveFocus                                             Thu Jan  1 18:37:49.313 2009  to  Thu Jan  1 18:37:49.643 2009   (  0.33) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus failure for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus failure for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

   3  FAILED    IIF        command.moveFocus                                             Thu Jan  1 18:43:27.662 2009  to  Thu Jan  1 18:43:27.942 2009   (  0.28) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus failure for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus failure for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

   4  FAILED    IIF        command.moveFocus                                             Thu Jan  1 18:47:10.247 2009  to  Thu Jan  1 18:47:10.616 2009   (  0.37) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus failure for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus failure for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

   5  FAILED    IIF        command.moveFocus                                             Thu Jan  1 18:49:43.007 2009  to  Thu Jan  1 18:49:43.215 2009   (  0.21) secs
                    IIF GetTrajectory command started for both LBC, start time 5.483307618055555e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus failure for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus failure for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

   6  FAILED    IIF        command.moveFocus                                             Thu Jan  1 19:19:43.747 2009  to  Thu Jan  1 19:19:44.168 2009   (  0.42) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus failure for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus failure for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

   7  FAILED    IIF        command.moveFocus                                             Thu Jan  1 19:36:16.578 2009  to  Thu Jan  1 19:36:16.831 2009   (  0.25) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus failure for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus failure for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

   8  FAILED    IIF        command.moveFocus                                             Thu Jan  1 19:53:25.637 2009  to  Thu Jan  1 19:53:25.857 2009   (  0.22) secs
                    IIF GetTrajectory command started for both LBC, start time 5.483312042824074e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus failure for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus failure for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

   9  FAILED    IIF        command.preset.(TRACK)                                        Fri Jan  2 01:50:11.247 2009  to  Fri Jan  2 01:50:17.847 2009   (  6.60) secs
                    IIF GetTrajectory command started for both LBC, start time 5.483336820601852e+04, time 3.480000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset failure for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF Preset failure for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset command failed for both LBC mode TRACK from IIF

  10  FAILED    IIF        command.moveFocus                                             Fri Jan  2 04:44:45.896 2009  to  Fri Jan  2 04:44:46.218 2009   (  0.32) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus failure for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus failure for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

  11  FAILED    IIF        command.moveFocus                                             Fri Jan  2 04:44:46.157 2009  to  Fri Jan  2 04:44:46.562 2009   (  0.41) secs
                    IIF MoveFocus failure for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus failure for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

  12  SEQERROR  IIF        command.offset                                                Fri Jan  2 06:56:47.359 2009  to  Fri Jan  2 06:56:47.383 2009   (  0.00) secs
                    Started event but no Complete event
                    IIF Offset command started for both LBC from IIF

  13  SEQERROR  IIF        command.offset                                                Fri Jan  2 06:56:47.383 2009  to  Fri Jan  2 06:56:47.408 2009   (  0.00) secs
                    Started event but no Complete event
                    IIF Offset command started for both LBC from IIF

  14  SEQERROR  IIF        command.offset                                                Fri Jan  2 06:57:21.885 2009  to  Fri Jan  2 06:57:21.885 2009   (  0.00) secs
                    Complete event but no Started event
                    IIF Offset command complete for both LBC from IIF

  15  SEQERROR  IIF        command.offset                                                Fri Jan  2 06:57:22.190 2009  to  Fri Jan  2 06:57:22.190 2009   (  0.00) secs
                    Complete event but no Started event
                    IIF Offset command complete for both LBC from IIF
**********************************************************
AOS Startup and Shutdown Activity                                  
      Nothing to report

AOS Command Event Activity                                         
      Nothing to report

AOS Single Event Activity                                          
      Nothing to report

AOS Events of Interest
      Nothing to report
**********************************************************
ECS Startup and Shutdown Activity                                  
      Nothing to report

ECS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     hydraulicBearing.command.setTemperatureSetPoint. . . . . . . .                                   100.0 %                  4614                      
                                                                                                   
     instrumentCooling.command.setTemperatureSetPt. . . . . . . . .                                   100.0 %                  9228                      
                                                                                                   
     lights.command.off . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     8                      
                                                                                                   
     lights.command.on. . . . . . . . . . . . . . . . . . . . . . .                                   100.0 %                     8                      
                                                                                                   
     mirrorVent.blower.command.resetAlarm . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     mirrorVent.blower.command.run. . . . . . . . . . . . . . . . .                                   100.0 %                     2                      
                                                                                                   
     mirrorVent.blower.command.stop . . . . . . . . . . . . . . . .                                   100.0 %                     1                      
                                                                                                   

ECS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     instrumentCooling.badWeatherData . . . . . . . . . . . . . . .                          4614
     hydraulicBearing.badWeatherData. . . . . . . . . . . . . . . .                          4614
     plc.writeHC.complete . . . . . . . . . . . . . . . . . . . . .      75                      

ECS Events of Interest
      Nothing to report
**********************************************************
ENV Startup and Shutdown Activity                                  
      Nothing to report

ENV Command Event Activity                                         
      Nothing to report

ENV Single Event Activity                                          
      Nothing to report

ENV Events of Interest
      Nothing to report
**********************************************************
GCS Startup and Shutdown Activity                                  
      Nothing to report

GCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.stopGuiding. . . . . . . . . . . . . . . . . . . . . .                                   100.0 %         66                                 
                                                                                                   

GCS Single Event Activity                                          
      Nothing to report

GCS Events of Interest
      Nothing to report
**********************************************************
LSS Startup and Shutdown Activity                                  
      Nothing to report

LSS Command Event Activity                                         
      Nothing to report

LSS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     subscribe. . . . . . . . . . . . . . . . . . . . . . . . . . .       1                      

LSS Events of Interest
      Nothing to report
**********************************************************
MCS.MCSPU Command Event Activity                                   
      Nothing to report

MCS.MCSPU Single Event Activity                                     started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
 *** MCSPU.Tracker.badPoly. . . . . . . . . . . . . . . . . . . . .                970           
     MCSPU.HydrostaticBearing.cmdInLocal. . . . . . . . . . . . . .                             2
     MCSPU.HydrostaticBearing.startStarted. . . . . . . . . . . . .       1                      
     MCSPU.HydrostaticBearing.HBS_on_sucessful. . . . . . . . . . .                             1
     MCSPU.HydrostaticBearing.stateChange . . . . . . . . . . . . .       1                      
     MCSPU.Enclosure.errot. . . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.AZDrive.driveCommand . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Amplifiers.allAmpsOff. . . . . . . . . . . . . . . . . .                             6
     MCSPU.AZDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.AZDrive.stateChange. . . . . . . . . . . . . . . . . . .      26                      
     MCSPU.Servo.zeroIntegrator . . . . . . . . . . . . . . . . . .                            12
     MCSPU.ELDrive.driveCommand . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.ampDisable . . . . . . . . . . . . . . . . . . .                             2
     MCSPU.Tracker.commandToVelMode . . . . . . . . . . . . . . . .       5                      
     MCSPU.ELDrive.stateChange. . . . . . . . . . . . . . . . . . .      17                      
     MCSPU.AZDrive.energizeStart. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.energizeStart. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.energizeAck. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.energizeAck. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.powerTurnedOn. . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Amplifiers.allAmpsOn . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.ampsOnAckFail. . . . . . . . . . . . . . . . . .                  2           
     MCSPU.ELDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ELDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Servo.setTorqueBias. . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.release . . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Brake.brakeCommand . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Brake.commandOK. . . . . . . . . . . . . . . . . . . . .       8                      
     MCSPU.Servo.setVelDemand . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.Servo.setPosMode . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Tracker.hold . . . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.Servo.dspTelemFreq . . . . . . . . . . . . . . . . . . .       4                      
     MCSPU.AZDrive.ampsOnAck. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.ampsOn . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.allBrakesRelQ . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.bldgReady. . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.AZDrive.AzBrakes.commandComplete . . . . . . . . . . . .       1                      
     MCSPU.Enclosure.ersetpoint . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Tracker.slewToTrack. . . . . . . . . . . . . . . . . . .     238                      
     MCSPU.Tracker.fromSlewToTrack. . . . . . . . . . . . . . . . .     195                      
     MCSPU.Tracker.slewToHold . . . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Tracker.slewToHoldDone . . . . . . . . . . . . . . . . .       3                      
     MCSPU.Servo.toVelMode. . . . . . . . . . . . . . . . . . . . .       2                      
     MCSPU.ELDrive.el_wait_opr_brakes . . . . . . . . . . . . . . .       1                      
     MCSPU.ElBrakes.set . . . . . . . . . . . . . . . . . . . . . .       1                      
     MCSPU.Tracker.polyStop . . . . . . . . . . . . . . . . . . . .                  2           

MCS.MCSPU Events of Interest

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:01.368 2009  to  Thu Jan  1 16:54:01.368 2009   (  0.00) secs
                    EL bad poly no. 356969: BAD: poly EL = -5.424298e-01 rad. Too low.

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:04.409 2009  to  Thu Jan  1 16:54:04.409 2009   (  0.00) secs
                    EL bad poly no. 357017: BAD: poly EL = -5.425541e-01 rad. Too low.

   3  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:07.426 2009  to  Thu Jan  1 16:54:07.426 2009   (  0.00) secs
                    EL bad poly no. 357063: BAD: poly EL = -5.426775e-01 rad. Too low.

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:10.425 2009  to  Thu Jan  1 16:54:10.425 2009   (  0.00) secs
                    EL bad poly no. 357110: BAD: poly EL = -5.428000e-01 rad. Too low.

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:13.480 2009  to  Thu Jan  1 16:54:13.480 2009   (  0.00) secs
                    EL bad poly no. 357158: BAD: poly EL = -5.429247e-01 rad. Too low.

   6  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:16.512 2009  to  Thu Jan  1 16:54:16.512 2009   (  0.00) secs
                    EL bad poly no. 357206: BAD: poly EL = -5.430486e-01 rad. Too low.

   7  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:19.499 2009  to  Thu Jan  1 16:54:19.499 2009   (  0.00) secs
                    EL bad poly no. 357252: BAD: poly EL = -5.431705e-01 rad. Too low.

   8  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:22.518 2009  to  Thu Jan  1 16:54:22.518 2009   (  0.00) secs
                    EL bad poly no. 357298: BAD: poly EL = -5.432937e-01 rad. Too low.

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:25.567 2009  to  Thu Jan  1 16:54:25.567 2009   (  0.00) secs
                    EL bad poly no. 357346: BAD: poly EL = -5.434182e-01 rad. Too low.

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:28.601 2009  to  Thu Jan  1 16:54:28.601 2009   (  0.00) secs
                    EL bad poly no. 357393: BAD: poly EL = -5.435419e-01 rad. Too low.

  11  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:31.622 2009  to  Thu Jan  1 16:54:31.622 2009   (  0.00) secs
                    EL bad poly no. 357440: BAD: poly EL = -5.436652e-01 rad. Too low.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:34.675 2009  to  Thu Jan  1 16:54:34.675 2009   (  0.00) secs
                    EL bad poly no. 357488: BAD: poly EL = -5.437897e-01 rad. Too low.

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:37.699 2009  to  Thu Jan  1 16:54:37.699 2009   (  0.00) secs
                    EL bad poly no. 357535: BAD: poly EL = -5.439130e-01 rad. Too low.

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:40.733 2009  to  Thu Jan  1 16:54:40.733 2009   (  0.00) secs
                    EL bad poly no. 357581: BAD: poly EL = -5.440367e-01 rad. Too low.

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:43.784 2009  to  Thu Jan  1 16:54:43.784 2009   (  0.00) secs
                    EL bad poly no. 357626: BAD: poly EL = -5.441610e-01 rad. Too low.

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:46.839 2009  to  Thu Jan  1 16:54:46.839 2009   (  0.00) secs
                    EL bad poly no. 357673: BAD: poly EL = -5.442855e-01 rad. Too low.

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:49.873 2009  to  Thu Jan  1 16:54:49.873 2009   (  0.00) secs
                    EL bad poly no. 357720: BAD: poly EL = -5.444090e-01 rad. Too low.

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:52.929 2009  to  Thu Jan  1 16:54:52.929 2009   (  0.00) secs
                    EL bad poly no. 357768: BAD: poly EL = -5.445335e-01 rad. Too low.

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:55.951 2009  to  Thu Jan  1 16:54:55.951 2009   (  0.00) secs
                    EL bad poly no. 357815: BAD: poly EL = -5.446566e-01 rad. Too low.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:58.990 2009  to  Thu Jan  1 16:54:58.990 2009   (  0.00) secs
                    EL bad poly no. 357861: BAD: poly EL = -5.447802e-01 rad. Too low.

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:55:02.041 2009  to  Thu Jan  1 16:55:02.041 2009   (  0.00) secs
                    EL bad poly no. 357908: BAD: poly EL = -5.449044e-01 rad. Too low.

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:55:05.098 2009  to  Thu Jan  1 16:55:05.098 2009   (  0.00) secs
                    EL bad poly no. 357956: BAD: poly EL = -5.450288e-01 rad. Too low.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:55:08.140 2009  to  Thu Jan  1 16:55:08.140 2009   (  0.00) secs
                    EL bad poly no. 358003: BAD: poly EL = -5.451525e-01 rad. Too low.

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:55:11.177 2009  to  Thu Jan  1 16:55:11.177 2009   (  0.00) secs
                    EL bad poly no. 358050: BAD: poly EL = -5.452761e-01 rad. Too low.

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:55:14.187 2009  to  Thu Jan  1 16:55:14.187 2009   (  0.00) secs
                    EL bad poly no. 358097: BAD: poly EL = -5.453984e-01 rad. Too low.

  26  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Thu Jan  1 17:37:21.857 2009  to  Thu Jan  1 17:37:21.857 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

  27  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Thu Jan  1 17:37:54.741 2009  to  Thu Jan  1 17:37:54.741 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

  28  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 07:40:44.105 2009  to  Fri Jan  2 07:40:44.105 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

  29  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 07:40:44.126 2009  to  Fri Jan  2 07:40:44.126 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .
**********************************************************
MCS Startup and Shutdown Activity                                  
      Nothing to report

MCS Command Event Activity                                         
      Nothing to report

MCS Single Event Activity                                          
      Nothing to report

MCS Events of Interest
      Nothing to report
**********************************************************
OSS Startup and Shutdown Activity                                  
      Nothing to report

OSS Command Event Activity                                         
      Nothing to report

OSS Single Event Activity                                          
      Nothing to report

OSS Events of Interest
      Nothing to report
**********************************************************
PCS Startup and Shutdown Activity                                     count
                                                                   --------
     startup. . . . . . . . . . . . . . . . . . . . . . . . . . . .       1
     shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . .       1

PCS Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     rotator.command.getRotatorTrajectory . . . . . . . . . . . . .    0.03    0.09    0.06    0.37   100.0 %        747        747                      
                                                                       0.03    0.09    0.06    0.37
     telescope.command.listPMTerms. . . . . . . . . . . . . . . . .    0.23    0.17    0.01    0.33   100.0 %          2          2                      
                                                                       0.23    0.17    0.01    0.33
     telescope.command.offsetTelescopeEquatorial. . . . . . . . . .    0.33    0.36    0.00    1.06   100.0 %         98         98                      
                                                                       0.33    0.37    0.01    1.06
     telescope.command.setNewTarget . . . . . . . . . . . . . . . .    0.34    0.48    0.02    0.99   100.0 %         37         37                      
                                                                       0.34    0.48    0.02    0.99
     telescope.command.startTracking. . . . . . . . . . . . . . . .    0.33    0.44    0.00    0.78   100.0 %         37         37                      
                                                                       0.13    0.65    0.52    0.78

PCS Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     telescope.telemetryInfo. . . . . . . . . . . . . . . . . . . .       2                      
     weather.telemetryInfo. . . . . . . . . . . . . . . . . . . . .       2                      
     guider.telemetryInfo . . . . . . . . . . . . . . . . . . . . .       2                      

PCS Events of Interest

   1  SEQERROR  PCS        telescope.command.startTracking                               Thu Jan  1 18:18:23.683 2009  to  Thu Jan  1 19:11:04.051 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   2  SEQERROR  PCS        telescope.command.startTracking                               Thu Jan  1 18:18:23.950 2009  to  Thu Jan  1 18:18:23.950 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   3  SEQERROR  PCS        telescope.command.startTracking                               Thu Jan  1 19:43:35.322 2009  to  Thu Jan  1 19:55:28.261 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   4  SEQERROR  PCS        telescope.command.startTracking                               Thu Jan  1 19:43:35.591 2009  to  Thu Jan  1 19:43:35.591 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   5  SEQERROR  PCS        telescope.command.startTracking                               Thu Jan  1 22:04:09.709 2009  to  Thu Jan  1 22:47:56.147 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   6  SEQERROR  PCS        telescope.command.startTracking                               Thu Jan  1 22:04:09.979 2009  to  Thu Jan  1 22:04:09.979 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   7  SEQERROR  PCS        telescope.command.startTracking                               Thu Jan  1 22:47:56.147 2009  to  Thu Jan  1 22:57:49.926 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

   8  SEQERROR  PCS        telescope.command.startTracking                               Thu Jan  1 22:47:56.415 2009  to  Thu Jan  1 22:47:56.415 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

   9  SEQERROR  PCS        telescope.command.startTracking                               Thu Jan  1 22:57:49.926 2009  to  Thu Jan  1 23:30:33.539 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  10  SEQERROR  PCS        telescope.command.startTracking                               Thu Jan  1 22:57:50.195 2009  to  Thu Jan  1 22:57:50.195 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  11  SEQERROR  PCS        telescope.command.startTracking                               Thu Jan  1 23:50:43.813 2009  to  Fri Jan  2 00:21:39.574 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  12  SEQERROR  PCS        telescope.command.startTracking                               Thu Jan  1 23:50:44.081 2009  to  Thu Jan  1 23:50:44.081 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  13  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 00:21:39.574 2009  to  Fri Jan  2 00:44:01.410 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  14  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 00:21:39.843 2009  to  Fri Jan  2 00:21:39.843 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  15  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 01:43:55.295 2009  to  Fri Jan  2 01:46:11.161 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  16  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 01:43:55.562 2009  to  Fri Jan  2 01:43:55.562 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  17  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 02:08:27.831 2009  to  Fri Jan  2 02:18:20.348 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  18  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 02:08:28.103 2009  to  Fri Jan  2 02:08:28.103 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  19  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 02:44:39.318 2009  to  Fri Jan  2 03:16:43.271 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  20  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 02:44:39.585 2009  to  Fri Jan  2 02:44:39.585 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  21  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 03:16:43.271 2009  to  Fri Jan  2 03:45:11.802 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  22  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 03:16:43.540 2009  to  Fri Jan  2 03:16:43.540 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  23  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 04:13:46.331 2009  to  Fri Jan  2 04:43:50.869 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  24  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 04:13:46.606 2009  to  Fri Jan  2 04:13:46.606 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  25  SXDXBOTH  PCS        telescope.command.listPMTerms                                 Fri Jan  2 05:24:43.805 2009  to  Fri Jan  2 05:24:43.813 2009   (  0.01) secs
                    

  26  SEQERROR  PCS        telescope.command.offsetTelescopeEquatorial                   Fri Jan  2 06:56:47.445 2009  to  Fri Jan  2 06:56:47.460 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS set offset equatorial started with delta RA = -1.668001469857359e-04, delta DEC = -4.462225120932169e-05

  27  SEQERROR  PCS        telescope.command.offsetTelescopeEquatorial                   Fri Jan  2 06:56:48.007 2009  to  Fri Jan  2 06:56:48.007 2009   (  0.00) secs
                    Complete event but no Started event
                    PCS set offset equatorial complete with delta RA = -1.668001469857359e-04, delta DEC = -4.462225120932169e-05

  28  SHUTDOWN  PCS        shutdown                                                      Fri Jan  2 07:40:43.746 2009  to  Fri Jan  2 07:40:43.746 2009   (  0.00) secs
                    PCS subsystem shut down - PCS Version 3.28f

  29  STARTUP   PCS        startup                                                       Fri Jan  2 07:41:00.254 2009  to  Fri Jan  2 07:41:00.254 2009   (  0.00) secs
                    PCS subsystem started - PCS Version 3.28e
**********************************************************
PMC Startup and Shutdown Activity                                  
      Nothing to report

PMC Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     actuator.command.changeOffsets.all . . . . . . . . . . . . . .    1.69    2.79    2.02   10.03   100.0 %         38         38                      
                                                                       1.69    2.79    2.02   10.03
     actuator.command.force.discardSoftAdjustments. . . . . . . . .   10.04   13.37    3.02   23.06   100.0 %          3          3                      
                                                                      10.04   13.37    3.02   23.06
     mirror.command.chase.stop. . . . . . . . . . . . . . . . . . .    0.01    2.02    2.02    2.04   100.0 %          4          4                      
                                                                       0.01    2.02    2.02    2.04
 *** mirror.command.goToPosition.absolute . . . . . . . . . . . . .    4.08    4.42    0.00   59.14    99.2 %       1922       1907         15           
                                                                       4.07    4.47    2.02   59.14
     thermal.command.setData. . . . . . . . . . . . . . . . . . . .    0.02    0.04    0.02    0.06   100.0 %          8          8                      
                                                                       0.02    0.04    0.02    0.06

PMC Single Event Activity                                           started     failed    warning
                                                                      count      count      count
                                                                   ------------------------------
     thermal.badWeatherData . . . . . . . . . . . . . . . . . . . .                         10667
     hardPoint.lvdt.noMotion. . . . . . . . . . . . . . . . . . . .                            56
 *** VxInterface.lengthError. . . . . . . . . . . . . . . . . . . .                 51           
 *** VxInterface.close. . . . . . . . . . . . . . . . . . . . . . .                 51           
     VxInterface.connect.success. . . . . . . . . . . . . . . . . .      51                      
     VxInterface.sequenceError. . . . . . . . . . . . . . . . . . .                            52
     clearingForceAdjustments . . . . . . . . . . . . . . . . . . .       3                      
     settingForceAdjustments. . . . . . . . . . . . . . . . . . . .      38                      
     mirror.mountbad. . . . . . . . . . . . . . . . . . . . . . . .       1                      
     mirror.mountok . . . . . . . . . . . . . . . . . . . . . . . .       1                      
     VxInterface.selectTimeout. . . . . . . . . . . . . . . . . . .                  5           
     VxInterface.packetReadError. . . . . . . . . . . . . . . . . .                  5           
     thermal.badReceive . . . . . . . . . . . . . . . . . . . . . .                  5           

PMC Events of Interest

   1  FAILED    PMC        VxInterface.close                                             Thu Jan  1 17:46:06.539 2009  to  Thu Jan  1 17:46:06.539 2009   (  0.00) secs
                    right PMC Actuator closing network connection

   2  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 17:46:06.487 2009  to  Thu Jan  1 17:46:06.487 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

   3  FAILED    PMC        VxInterface.close                                             Thu Jan  1 17:54:33.560 2009  to  Thu Jan  1 17:54:33.560 2009   (  0.00) secs
                    left PMC Actuator closing network connection

   4  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 17:54:33.508 2009  to  Thu Jan  1 17:54:33.508 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

   5  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:20:50.187 2009  to  Thu Jan  1 18:21:07.243 2009   ( 17.06) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   6  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:26:22.456 2009  to  Thu Jan  1 18:26:33.678 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   7  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:26:33.678 2009  to  Thu Jan  1 18:26:33.692 2009   (  0.01) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   8  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:26:50.531 2009  to  Thu Jan  1 18:26:50.531 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

   9  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:29:07.845 2009  to  Thu Jan  1 18:29:11.880 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  10  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:29:11.880 2009  to  Thu Jan  1 18:29:11.897 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  11  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:29:12.873 2009  to  Thu Jan  1 18:29:12.873 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  12  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:34:17.523 2009  to  Thu Jan  1 18:34:22.547 2009   (  5.02) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  13  FAILED    PMC        VxInterface.close                                             Thu Jan  1 18:35:30.655 2009  to  Thu Jan  1 18:35:30.655 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  14  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 18:35:30.638 2009  to  Thu Jan  1 18:35:30.638 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  15  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:37:34.967 2009  to  Thu Jan  1 18:37:49.451 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  16  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:37:49.451 2009  to  Thu Jan  1 18:37:49.474 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  17  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:38:30.092 2009  to  Thu Jan  1 18:38:30.092 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  18  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:43:25.229 2009  to  Thu Jan  1 18:43:27.750 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  19  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:43:27.750 2009  to  Thu Jan  1 18:43:27.769 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  20  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:43:29.250 2009  to  Thu Jan  1 18:43:29.250 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  21  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 18:43:29.766 2009  to  Thu Jan  1 18:43:29.766 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  22  FAILED    PMC        VxInterface.close                                             Thu Jan  1 18:43:29.817 2009  to  Thu Jan  1 18:43:29.817 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  23  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:47:08.280 2009  to  Thu Jan  1 18:47:10.332 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  24  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:47:10.332 2009  to  Thu Jan  1 18:47:10.348 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  25  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:47:26.332 2009  to  Thu Jan  1 18:47:26.332 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  26  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:49:29.594 2009  to  Thu Jan  1 18:49:43.080 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  27  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:49:43.080 2009  to  Thu Jan  1 18:49:43.100 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  28  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:49:54.658 2009  to  Thu Jan  1 18:49:54.658 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  29  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:52:13.691 2009  to  Thu Jan  1 18:52:21.723 2009   (  8.03) secs
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  30  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 19:19:38.679 2009  to  Thu Jan  1 19:19:43.988 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started

  31  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 19:19:43.988 2009  to  Thu Jan  1 19:19:44.006 2009   (  0.02) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  32  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 19:19:47.235 2009  to  Thu Jan  1 19:19:47.235 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  33  FAILED    PMC        VxInterface.close                                             Thu Jan  1 19:19:47.261 2009  to  Thu Jan  1 19:19:47.261 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  34  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 19:19:50.721 2009  to  Thu Jan  1 19:19:50.721 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  35  FAILED    PMC        thermal.badReceive                                            Thu Jan  1 19:19:51.336 2009  to  Thu Jan  1 19:19:51.336 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  36  FAILED    PMC        VxInterface.packetReadError                                   Thu Jan  1 19:19:51.320 2009  to  Thu Jan  1 19:19:51.320 2009   (  0.00) secs
                    left PMC Thermal packet read error: 5002

  37  FAILED    PMC        VxInterface.selectTimeout                                     Thu Jan  1 19:19:51.305 2009  to  Thu Jan  1 19:19:51.305 2009   (  0.00) secs
                    left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  38  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 19:35:57.383 2009  to  Thu Jan  1 19:36:16.665 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started

  39  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 19:57:32.796 2009  to  Thu Jan  1 19:57:32.796 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  40  FAILED    PMC        VxInterface.close                                             Thu Jan  1 19:57:32.825 2009  to  Thu Jan  1 19:57:32.825 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  41  FAILED    PMC        thermal.badReceive                                            Thu Jan  1 19:58:13.401 2009  to  Thu Jan  1 19:58:13.401 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  42  FAILED    PMC        VxInterface.packetReadError                                   Thu Jan  1 19:58:13.387 2009  to  Thu Jan  1 19:58:13.387 2009   (  0.00) secs
                    left PMC Thermal packet read error: 5002

  43  FAILED    PMC        VxInterface.selectTimeout                                     Thu Jan  1 19:58:13.369 2009  to  Thu Jan  1 19:58:13.369 2009   (  0.00) secs
                    left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  44  FAILED    PMC        VxInterface.close                                             Thu Jan  1 19:58:59.801 2009  to  Thu Jan  1 19:58:59.801 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  45  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 19:58:59.783 2009  to  Thu Jan  1 19:58:59.783 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  46  FAILED    PMC        VxInterface.close                                             Thu Jan  1 19:59:35.793 2009  to  Thu Jan  1 19:59:35.793 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  47  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 19:59:35.777 2009  to  Thu Jan  1 19:59:35.777 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  48  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 20:08:46.294 2009  to  Thu Jan  1 20:08:46.294 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  49  FAILED    PMC        VxInterface.close                                             Thu Jan  1 20:08:46.322 2009  to  Thu Jan  1 20:08:46.322 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  50  FAILED    PMC        VxInterface.close                                             Thu Jan  1 20:11:06.289 2009  to  Thu Jan  1 20:11:06.289 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

  51  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 20:11:06.274 2009  to  Thu Jan  1 20:11:06.274 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

  52  FAILED    PMC        VxInterface.close                                             Thu Jan  1 20:38:26.741 2009  to  Thu Jan  1 20:38:26.741 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  53  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 20:38:26.728 2009  to  Thu Jan  1 20:38:26.728 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  54  FAILED    PMC        VxInterface.close                                             Thu Jan  1 21:06:45.603 2009  to  Thu Jan  1 21:06:45.603 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  55  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 21:06:45.570 2009  to  Thu Jan  1 21:06:45.570 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  56  FAILED    PMC        VxInterface.close                                             Thu Jan  1 21:46:42.625 2009  to  Thu Jan  1 21:46:42.625 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  57  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 21:46:42.609 2009  to  Thu Jan  1 21:46:42.609 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  58  FAILED    PMC        thermal.badReceive                                            Thu Jan  1 21:50:44.006 2009  to  Thu Jan  1 21:50:44.006 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  59  FAILED    PMC        VxInterface.packetReadError                                   Thu Jan  1 21:50:43.991 2009  to  Thu Jan  1 21:50:43.991 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

  60  FAILED    PMC        VxInterface.selectTimeout                                     Thu Jan  1 21:50:43.975 2009  to  Thu Jan  1 21:50:43.975 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  61  FAILED    PMC        VxInterface.close                                             Thu Jan  1 22:01:50.890 2009  to  Thu Jan  1 22:01:50.890 2009   (  0.00) secs
                    left PMC Mirror closing network connection

  62  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 22:01:50.873 2009  to  Thu Jan  1 22:01:50.873 2009   (  0.00) secs
                    left PMC Mirror length error: expected 92, got 96

  63  FAILED    PMC        VxInterface.close                                             Thu Jan  1 22:03:44.073 2009  to  Thu Jan  1 22:03:44.073 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

  64  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 22:03:44.056 2009  to  Thu Jan  1 22:03:44.056 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

  65  FAILED    PMC        VxInterface.close                                             Thu Jan  1 22:15:14.068 2009  to  Thu Jan  1 22:15:14.068 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  66  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 22:15:14.052 2009  to  Thu Jan  1 22:15:14.052 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  67  FAILED    PMC        VxInterface.close                                             Thu Jan  1 22:34:13.597 2009  to  Thu Jan  1 22:34:13.597 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

  68  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 22:34:13.580 2009  to  Thu Jan  1 22:34:13.580 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

  69  FAILED    PMC        VxInterface.close                                             Thu Jan  1 22:58:32.073 2009  to  Thu Jan  1 22:58:32.073 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  70  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 22:58:32.054 2009  to  Thu Jan  1 22:58:32.054 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  71  FAILED    PMC        VxInterface.close                                             Thu Jan  1 23:08:37.786 2009  to  Thu Jan  1 23:08:37.786 2009   (  0.00) secs
                    left PMC Mirror closing network connection

  72  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 23:08:37.769 2009  to  Thu Jan  1 23:08:37.769 2009   (  0.00) secs
                    left PMC Mirror length error: expected 92, got 96

  73  FAILED    PMC        VxInterface.close                                             Thu Jan  1 23:15:59.022 2009  to  Thu Jan  1 23:15:59.022 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  74  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 23:15:59.003 2009  to  Thu Jan  1 23:15:59.003 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  75  FAILED    PMC        VxInterface.close                                             Thu Jan  1 23:23:57.648 2009  to  Thu Jan  1 23:23:57.648 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  76  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 23:23:57.631 2009  to  Thu Jan  1 23:23:57.631 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  77  FAILED    PMC        VxInterface.close                                             Thu Jan  1 23:33:21.555 2009  to  Thu Jan  1 23:33:21.555 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  78  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 23:33:21.538 2009  to  Thu Jan  1 23:33:21.538 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  79  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 23:59:19.712 2009  to  Thu Jan  1 23:59:19.712 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  80  FAILED    PMC        VxInterface.close                                             Thu Jan  1 23:59:19.729 2009  to  Thu Jan  1 23:59:19.729 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  81  FAILED    PMC        VxInterface.close                                             Fri Jan  2 00:12:49.704 2009  to  Fri Jan  2 00:12:49.704 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  82  FAILED    PMC        VxInterface.lengthError                                       Fri Jan  2 00:12:49.690 2009  to  Fri Jan  2 00:12:49.690 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  83  FAILED    PMC        VxInterface.lengthError                                       Fri Jan  2 00:27:10.561 2009  to  Fri Jan  2 00:27:10.561 2009   (  0.00) secs
                    right PMC PMC length error: expected 32, got 96

  84  FAILED    PMC        VxInterface.close                                             Fri Jan  2 00:27:10.613 2009  to  Fri Jan  2 00:27:10.613 2009   (  0.00) secs
                    right PMC PMC closing network connection

  85  FAILED    PMC        thermal.badReceive                                            Fri Jan  2 01:59:27.881 2009  to  Fri Jan  2 01:59:27.881 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  86  FAILED    PMC        VxInterface.packetReadError                                   Fri Jan  2 01:59:27.862 2009  to  Fri Jan  2 01:59:27.862 2009   (  0.00) secs
                    left PMC Thermal packet read error: 5002

  87  FAILED    PMC        VxInterface.selectTimeout                                     Fri Jan  2 01:59:27.839 2009  to  Fri Jan  2 01:59:27.839 2009   (  0.00) secs
                    left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  88  FAILED    PMC        VxInterface.selectTimeout                                     Fri Jan  2 03:15:47.617 2009  to  Fri Jan  2 03:15:47.617 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

  89  FAILED    PMC        thermal.badReceive                                            Fri Jan  2 03:15:47.648 2009  to  Fri Jan  2 03:15:47.648 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

  90  FAILED    PMC        VxInterface.packetReadError                                   Fri Jan  2 03:15:47.632 2009  to  Fri Jan  2 03:15:47.632 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002
**********************************************************
PSF Startup and Shutdown Activity                                  
      Nothing to report

PSF Command Event Activity                                           stddev    mean     min     max   percent    started  completed     failed    warning  remaining
                                                                       secs    secs    secs    secs   success      count      count      count      count     counts
                                                                   -------------------------------------------------------------------------------------------------
     command.applyZernikes. . . . . . . . . . . . . . . . . . . . .    1.94    3.56    0.28   16.61   100.0 %        915        915                      
                                                                       1.94    3.56    0.28   16.61
     command.setInstrumentOffsets . . . . . . . . . . . . . . . . .    4.04    5.00    0.14   36.23    99.0 %       1001        991         10           
                                                                       4.04    5.05    2.13   36.23
     command.setZernikes. . . . . . . . . . . . . . . . . . . . . .    1.93    3.61    0.31   16.65   100.0 %        915        915                      
                                                                       1.93    3.61    0.31   16.65
     primaryMirror.command.adjustMirror . . . . . . . . . . . . . .    3.55    3.81    0.21   55.42    99.7 %        936        933          3           
                                                                       3.55    3.80    0.21   55.42
 *** primaryMirror.command.adjustMirrorCollimation. . . . . . . . .    4.08    4.51    0.00   59.19    99.2 %       1922       1907         15           
                                                                       4.07    4.56    2.07   59.19
     primaryMirror.command.chaseStop. . . . . . . . . . . . . . . .    0.03    2.09    2.07    2.12   100.0 %          4          4                      
                                                                       0.03    2.09    2.07    2.12
     primaryMirror.command.clearForces. . . . . . . . . . . . . . .   10.04   13.44    3.09   23.12   100.0 %          3          3                      
                                                                      10.04   13.44    3.09   23.12
     primaryMirror.command.initForceCalc. . . . . . . . . . . . . .    0.04    0.06    0.03    0.31   100.0 %         84         84                      
                                                                       0.04    0.06    0.03    0.31
     primaryMirror.command.initMirrorCollimation. . . . . . . . . .    0.00    0.11    0.11    0.11   100.0 %          1          1                      
                                                                       0.00    0.11    0.11    0.11
     primaryMirror.command.revert . . . . . . . . . . . . . . . . .   33.34   44.31   20.28   82.37    66.7 %          3          2          1           
                                                                      36.83   56.33   30.28   82.37
     primaryMirror.command.setGlobalOffsets . . . . . . . . . . . .    8.56   13.28    3.12   33.20   100.0 %         16         16                      
                                                                       8.56   13.28    3.12   33.20
     primaryMirror.command.setLocalOffsets. . . . . . . . . . . . .    4.03    4.93    0.10   36.19    99.0 %       1001        991         10           
                                                                       4.02    4.97    2.10   36.19
     primaryMirror.command.setModesGains. . . . . . . . . . . . . .    0.01    0.03    0.02    0.06   100.0 %         21         21                      
                                                                       0.01    0.03    0.02    0.06
     primaryMirror.command.setZernikes. . . . . . . . . . . . . . .    0.01    0.02    0.01    0.13   100.0 %        936        936                      
                                                                       0.01    0.02    0.01    0.13

PSF Single Event Activity                                          
      Nothing to report

PSF Events of Interest

   1  FAILED    PSF        primaryMirror.command.revert                                  Thu Jan  1 18:20:47.014 2009  to  Thu Jan  1 18:21:07.296 2009   ( 20.28) secs
                    left PSF primary mirror revert to just collimation table failed because left PMC Actuator DiscardSoftForceAdjustments Command Complete

   2  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:20:50.158 2009  to  Thu Jan  1 18:21:07.274 2009   ( 17.12) secs
                    left PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

   3  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:26:22.328 2009  to  Thu Jan  1 18:26:33.652 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   4  FAILED    PSF        command.setInstrumentOffsets                                  Thu Jan  1 18:26:33.621 2009  to  Thu Jan  1 18:26:33.767 2009   (  0.15) secs
                    right PSF SetInstrumentOffsets started
                    left PSF SetInstrumentOffsets failed

   5  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:26:33.652 2009  to  Thu Jan  1 18:26:33.723 2009   (  0.07) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

   6  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Jan  1 18:26:33.637 2009  to  Thu Jan  1 18:26:33.742 2009   (  0.10) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

   7  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:26:50.567 2009  to  Thu Jan  1 18:26:50.567 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

   8  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Jan  1 18:29:06.286 2009  to  Thu Jan  1 18:29:11.955 2009   (  5.67) secs
                    left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Complete

   9  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:29:07.818 2009  to  Thu Jan  1 18:29:11.851 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  10  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:29:11.851 2009  to  Thu Jan  1 18:29:11.931 2009   (  0.08) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  11  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:29:12.905 2009  to  Thu Jan  1 18:29:12.905 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  12  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Jan  1 18:34:17.234 2009  to  Thu Jan  1 18:34:22.600 2009   (  5.37) secs
                    left PSF primary mirror force adjustments failed because Primary mirror collimation reached limit

  13  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:34:17.497 2009  to  Thu Jan  1 18:34:22.580 2009   (  5.08) secs
                    left PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  14  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:37:34.940 2009  to  Thu Jan  1 18:37:49.422 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  15  FAILED    PSF        command.setInstrumentOffsets                                  Thu Jan  1 18:37:49.375 2009  to  Thu Jan  1 18:37:49.575 2009   (  0.20) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF SetInstrumentOffsets failed

  16  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:37:49.422 2009  to  Thu Jan  1 18:37:49.518 2009   (  0.10) secs
                    right PSF SetInstrumentOffsets started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  17  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Jan  1 18:37:49.390 2009  to  Thu Jan  1 18:37:49.541 2009   (  0.15) secs
                    right PSF primary mirror setLocalOffsets started
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  18  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:38:30.121 2009  to  Thu Jan  1 18:38:30.121 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  19  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:43:25.200 2009  to  Thu Jan  1 18:43:27.719 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  20  FAILED    PSF        command.setInstrumentOffsets                                  Thu Jan  1 18:43:27.682 2009  to  Thu Jan  1 18:43:27.853 2009   (  0.17) secs
                    right PSF SetInstrumentOffsets started
                    left PSF SetInstrumentOffsets failed

  21  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Jan  1 18:43:27.698 2009  to  Thu Jan  1 18:43:27.823 2009   (  0.13) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  22  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:43:27.719 2009  to  Thu Jan  1 18:43:27.803 2009   (  0.08) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  23  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:43:29.280 2009  to  Thu Jan  1 18:43:29.280 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  24  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:47:08.253 2009  to  Thu Jan  1 18:47:10.294 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  25  FAILED    PSF        command.setInstrumentOffsets                                  Thu Jan  1 18:47:10.267 2009  to  Thu Jan  1 18:47:10.532 2009   (  0.26) secs
                    right PSF SetInstrumentOffsets started
                    left PSF SetInstrumentOffsets failed

  26  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:47:10.294 2009  to  Thu Jan  1 18:47:10.378 2009   (  0.08) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  27  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Jan  1 18:47:10.281 2009  to  Thu Jan  1 18:47:10.398 2009   (  0.12) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  28  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:47:26.368 2009  to  Thu Jan  1 18:47:26.368 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  29  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:49:29.560 2009  to  Thu Jan  1 18:49:43.058 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  30  FAILED    PSF        command.setInstrumentOffsets                                  Thu Jan  1 18:49:43.029 2009  to  Thu Jan  1 18:49:43.167 2009   (  0.14) secs
                    left PSF SetInstrumentOffsets failed

  31  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:49:43.058 2009  to  Thu Jan  1 18:49:43.129 2009   (  0.07) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  32  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Jan  1 18:49:43.043 2009  to  Thu Jan  1 18:49:43.147 2009   (  0.10) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  33  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:49:54.707 2009  to  Thu Jan  1 18:49:54.707 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  34  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Jan  1 18:52:13.438 2009  to  Thu Jan  1 18:52:21.789 2009   (  8.35) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  35  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:52:13.662 2009  to  Thu Jan  1 18:52:21.770 2009   (  8.11) secs
                    left PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  36  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 19:19:38.575 2009  to  Thu Jan  1 19:19:43.946 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  37  FAILED    PSF        command.setInstrumentOffsets                                  Thu Jan  1 19:19:43.887 2009  to  Thu Jan  1 19:19:44.094 2009   (  0.21) secs
                    left PSF SetInstrumentOffsets failed

  38  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 19:19:43.946 2009  to  Thu Jan  1 19:19:44.052 2009   (  0.11) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  39  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Jan  1 19:19:43.911 2009  to  Thu Jan  1 19:19:44.073 2009   (  0.16) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  40  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 19:19:50.750 2009  to  Thu Jan  1 19:19:50.750 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  41  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 19:35:57.356 2009  to  Thu Jan  1 19:36:16.640 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  42  FAILED    PSF        command.setInstrumentOffsets                                  Thu Jan  1 19:36:16.599 2009  to  Thu Jan  1 19:36:16.751 2009   (  0.15) secs
                    right PSF SetInstrumentOffsets started
                    left PSF SetInstrumentOffsets failed

  43  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Jan  1 19:36:16.617 2009  to  Thu Jan  1 19:36:16.728 2009   (  0.11) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  44  FAILED    PSF        command.setInstrumentOffsets                                  Thu Jan  1 19:53:25.660 2009  to  Thu Jan  1 19:53:25.806 2009   (  0.15) secs
                    left PSF SetInstrumentOffsets failed

  45  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Jan  1 19:53:25.675 2009  to  Thu Jan  1 19:53:25.786 2009   (  0.11) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  46  FAILED    PSF        command.setInstrumentOffsets                                  Fri Jan  2 04:44:45.929 2009  to  Fri Jan  2 04:44:46.112 2009   (  0.18) secs
                    left PSF SetInstrumentOffsets failed

  47  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Jan  2 04:44:45.964 2009  to  Fri Jan  2 04:44:46.092 2009   (  0.13) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  48  FAILED    PSF        command.setInstrumentOffsets                                  Fri Jan  2 04:44:46.177 2009  to  Fri Jan  2 04:44:46.510 2009   (  0.33) secs
                    right PSF SetInstrumentOffsets failed

  49  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Jan  2 04:44:46.206 2009  to  Fri Jan  2 04:44:46.479 2009   (  0.27) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed
**********************************************************
SDB Startup and Shutdown Activity                                  
      Nothing to report

SDB Command Event Activity                                         
      Nothing to report

SDB Single Event Activity                                          
      Nothing to report

SDB Events of Interest
      Nothing to report
**********************************************************
All Events of Interest - Chronological Order

   1  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:01.368 2009  to  Thu Jan  1 16:54:01.368 2009   (  0.00) secs
                    EL bad poly no. 356969: BAD: poly EL = -5.424298e-01 rad. Too low.

   2  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:04.409 2009  to  Thu Jan  1 16:54:04.409 2009   (  0.00) secs
                    EL bad poly no. 357017: BAD: poly EL = -5.425541e-01 rad. Too low.

   3  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:07.426 2009  to  Thu Jan  1 16:54:07.426 2009   (  0.00) secs
                    EL bad poly no. 357063: BAD: poly EL = -5.426775e-01 rad. Too low.

   4  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:10.425 2009  to  Thu Jan  1 16:54:10.425 2009   (  0.00) secs
                    EL bad poly no. 357110: BAD: poly EL = -5.428000e-01 rad. Too low.

   5  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:13.480 2009  to  Thu Jan  1 16:54:13.480 2009   (  0.00) secs
                    EL bad poly no. 357158: BAD: poly EL = -5.429247e-01 rad. Too low.

   6  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:16.512 2009  to  Thu Jan  1 16:54:16.512 2009   (  0.00) secs
                    EL bad poly no. 357206: BAD: poly EL = -5.430486e-01 rad. Too low.

   7  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:19.499 2009  to  Thu Jan  1 16:54:19.499 2009   (  0.00) secs
                    EL bad poly no. 357252: BAD: poly EL = -5.431705e-01 rad. Too low.

   8  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:22.518 2009  to  Thu Jan  1 16:54:22.518 2009   (  0.00) secs
                    EL bad poly no. 357298: BAD: poly EL = -5.432937e-01 rad. Too low.

   9  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:25.567 2009  to  Thu Jan  1 16:54:25.567 2009   (  0.00) secs
                    EL bad poly no. 357346: BAD: poly EL = -5.434182e-01 rad. Too low.

  10  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:28.601 2009  to  Thu Jan  1 16:54:28.601 2009   (  0.00) secs
                    EL bad poly no. 357393: BAD: poly EL = -5.435419e-01 rad. Too low.

  11  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:31.622 2009  to  Thu Jan  1 16:54:31.622 2009   (  0.00) secs
                    EL bad poly no. 357440: BAD: poly EL = -5.436652e-01 rad. Too low.

  12  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:34.675 2009  to  Thu Jan  1 16:54:34.675 2009   (  0.00) secs
                    EL bad poly no. 357488: BAD: poly EL = -5.437897e-01 rad. Too low.

  13  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:37.699 2009  to  Thu Jan  1 16:54:37.699 2009   (  0.00) secs
                    EL bad poly no. 357535: BAD: poly EL = -5.439130e-01 rad. Too low.

  14  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:40.733 2009  to  Thu Jan  1 16:54:40.733 2009   (  0.00) secs
                    EL bad poly no. 357581: BAD: poly EL = -5.440367e-01 rad. Too low.

  15  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:43.784 2009  to  Thu Jan  1 16:54:43.784 2009   (  0.00) secs
                    EL bad poly no. 357626: BAD: poly EL = -5.441610e-01 rad. Too low.

  16  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:46.839 2009  to  Thu Jan  1 16:54:46.839 2009   (  0.00) secs
                    EL bad poly no. 357673: BAD: poly EL = -5.442855e-01 rad. Too low.

  17  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:49.873 2009  to  Thu Jan  1 16:54:49.873 2009   (  0.00) secs
                    EL bad poly no. 357720: BAD: poly EL = -5.444090e-01 rad. Too low.

  18  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:52.929 2009  to  Thu Jan  1 16:54:52.929 2009   (  0.00) secs
                    EL bad poly no. 357768: BAD: poly EL = -5.445335e-01 rad. Too low.

  19  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:55.951 2009  to  Thu Jan  1 16:54:55.951 2009   (  0.00) secs
                    EL bad poly no. 357815: BAD: poly EL = -5.446566e-01 rad. Too low.

  20  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:54:58.990 2009  to  Thu Jan  1 16:54:58.990 2009   (  0.00) secs
                    EL bad poly no. 357861: BAD: poly EL = -5.447802e-01 rad. Too low.

  21  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:55:02.041 2009  to  Thu Jan  1 16:55:02.041 2009   (  0.00) secs
                    EL bad poly no. 357908: BAD: poly EL = -5.449044e-01 rad. Too low.

  22  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:55:05.098 2009  to  Thu Jan  1 16:55:05.098 2009   (  0.00) secs
                    EL bad poly no. 357956: BAD: poly EL = -5.450288e-01 rad. Too low.

  23  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:55:08.140 2009  to  Thu Jan  1 16:55:08.140 2009   (  0.00) secs
                    EL bad poly no. 358003: BAD: poly EL = -5.451525e-01 rad. Too low.

  24  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:55:11.177 2009  to  Thu Jan  1 16:55:11.177 2009   (  0.00) secs
                    EL bad poly no. 358050: BAD: poly EL = -5.452761e-01 rad. Too low.

  25  FAILED    MCS.MCSPU  MCSPU.Tracker.badPoly                                         Thu Jan  1 16:55:14.187 2009  to  Thu Jan  1 16:55:14.187 2009   (  0.00) secs
                    EL bad poly no. 358097: BAD: poly EL = -5.453984e-01 rad. Too low.

  26  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Thu Jan  1 17:37:21.857 2009  to  Thu Jan  1 17:37:21.857 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

  27  FAILED    MCS.MCSPU  MCSPU.AZDrive.ampsOnAckFail                                   Thu Jan  1 17:37:54.741 2009  to  Thu Jan  1 17:37:54.741 2009   (  0.00) secs
                    TPLC has failed to acknowledge a command to turn on the power amplifiers.

  28  FAILED    PMC        VxInterface.close                                             Thu Jan  1 17:46:06.539 2009  to  Thu Jan  1 17:46:06.539 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  29  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 17:46:06.487 2009  to  Thu Jan  1 17:46:06.487 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  30  FAILED    PMC        VxInterface.close                                             Thu Jan  1 17:54:33.560 2009  to  Thu Jan  1 17:54:33.560 2009   (  0.00) secs
                    left PMC Actuator closing network connection

  31  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 17:54:33.508 2009  to  Thu Jan  1 17:54:33.508 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

  32  SEQERROR  PCS        telescope.command.startTracking                               Thu Jan  1 18:18:23.683 2009  to  Thu Jan  1 19:11:04.051 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

  33  SEQERROR  PCS        telescope.command.startTracking                               Thu Jan  1 18:18:23.950 2009  to  Thu Jan  1 18:18:23.950 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

  34  FAILED    PSF        primaryMirror.command.revert                                  Thu Jan  1 18:20:47.014 2009  to  Thu Jan  1 18:21:07.296 2009   ( 20.28) secs
                    left PSF primary mirror revert to just collimation table failed because left PMC Actuator DiscardSoftForceAdjustments Command Complete

  35  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:20:50.187 2009  to  Thu Jan  1 18:21:07.243 2009   ( 17.06) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  36  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:20:50.158 2009  to  Thu Jan  1 18:21:07.274 2009   ( 17.12) secs
                    left PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  37  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:26:22.328 2009  to  Thu Jan  1 18:26:33.652 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  38  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:26:22.456 2009  to  Thu Jan  1 18:26:33.678 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  39  FAILED    PSF        command.setInstrumentOffsets                                  Thu Jan  1 18:26:33.621 2009  to  Thu Jan  1 18:26:33.767 2009   (  0.15) secs
                    right PSF SetInstrumentOffsets started
                    left PSF SetInstrumentOffsets failed

  40  FAILED    IIF        command.moveFocus                                             Thu Jan  1 18:26:33.603 2009  to  Thu Jan  1 18:26:33.869 2009   (  0.27) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus failure for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus failure for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

  41  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:26:33.678 2009  to  Thu Jan  1 18:26:33.692 2009   (  0.01) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  42  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:26:33.652 2009  to  Thu Jan  1 18:26:33.723 2009   (  0.07) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  43  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Jan  1 18:26:33.637 2009  to  Thu Jan  1 18:26:33.742 2009   (  0.10) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  44  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:26:50.531 2009  to  Thu Jan  1 18:26:50.531 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  45  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:26:50.567 2009  to  Thu Jan  1 18:26:50.567 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  46  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Jan  1 18:29:06.286 2009  to  Thu Jan  1 18:29:11.955 2009   (  5.67) secs
                    left PSF primary mirror force adjustments failed because left PMC Actuator ChangeAllOffsets Command Complete

  47  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:29:07.845 2009  to  Thu Jan  1 18:29:11.880 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  48  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:29:07.818 2009  to  Thu Jan  1 18:29:11.851 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  49  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:29:11.880 2009  to  Thu Jan  1 18:29:11.897 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  50  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:29:11.851 2009  to  Thu Jan  1 18:29:11.931 2009   (  0.08) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  51  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:29:12.873 2009  to  Thu Jan  1 18:29:12.873 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  52  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:29:12.905 2009  to  Thu Jan  1 18:29:12.905 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  53  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Jan  1 18:34:17.234 2009  to  Thu Jan  1 18:34:22.600 2009   (  5.37) secs
                    left PSF primary mirror force adjustments failed because Primary mirror collimation reached limit

  54  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:34:17.497 2009  to  Thu Jan  1 18:34:22.580 2009   (  5.08) secs
                    left PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because Primary mirror collimation reached limit

  55  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:34:17.523 2009  to  Thu Jan  1 18:34:22.547 2009   (  5.02) secs
                    left PMC Mirror ChaseStop Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  56  FAILED    PMC        VxInterface.close                                             Thu Jan  1 18:35:30.655 2009  to  Thu Jan  1 18:35:30.655 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  57  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 18:35:30.638 2009  to  Thu Jan  1 18:35:30.638 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  58  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:37:34.967 2009  to  Thu Jan  1 18:37:49.451 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  59  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:37:34.940 2009  to  Thu Jan  1 18:37:49.422 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

  60  FAILED    IIF        command.moveFocus                                             Thu Jan  1 18:37:49.313 2009  to  Thu Jan  1 18:37:49.643 2009   (  0.33) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus failure for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus failure for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

  61  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:37:49.451 2009  to  Thu Jan  1 18:37:49.474 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  62  FAILED    PSF        command.setInstrumentOffsets                                  Thu Jan  1 18:37:49.375 2009  to  Thu Jan  1 18:37:49.575 2009   (  0.20) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF SetInstrumentOffsets failed

  63  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:37:49.422 2009  to  Thu Jan  1 18:37:49.518 2009   (  0.10) secs
                    right PSF SetInstrumentOffsets started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  64  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Jan  1 18:37:49.390 2009  to  Thu Jan  1 18:37:49.541 2009   (  0.15) secs
                    right PSF primary mirror setLocalOffsets started
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  65  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:38:30.092 2009  to  Thu Jan  1 18:38:30.092 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  66  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:38:30.121 2009  to  Thu Jan  1 18:38:30.121 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  67  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:43:25.200 2009  to  Thu Jan  1 18:43:27.719 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  68  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:43:25.229 2009  to  Thu Jan  1 18:43:27.750 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  69  FAILED    PSF        command.setInstrumentOffsets                                  Thu Jan  1 18:43:27.682 2009  to  Thu Jan  1 18:43:27.853 2009   (  0.17) secs
                    right PSF SetInstrumentOffsets started
                    left PSF SetInstrumentOffsets failed

  70  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Jan  1 18:43:27.698 2009  to  Thu Jan  1 18:43:27.823 2009   (  0.13) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  71  FAILED    IIF        command.moveFocus                                             Thu Jan  1 18:43:27.662 2009  to  Thu Jan  1 18:43:27.942 2009   (  0.28) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus failure for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus failure for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

  72  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:43:27.750 2009  to  Thu Jan  1 18:43:27.769 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  73  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:43:27.719 2009  to  Thu Jan  1 18:43:27.803 2009   (  0.08) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  74  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:43:29.250 2009  to  Thu Jan  1 18:43:29.250 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  75  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:43:29.280 2009  to  Thu Jan  1 18:43:29.280 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  76  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 18:43:29.766 2009  to  Thu Jan  1 18:43:29.766 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

  77  FAILED    PMC        VxInterface.close                                             Thu Jan  1 18:43:29.817 2009  to  Thu Jan  1 18:43:29.817 2009   (  0.00) secs
                    right PMC Actuator closing network connection

  78  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:47:08.280 2009  to  Thu Jan  1 18:47:10.332 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  79  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:47:08.253 2009  to  Thu Jan  1 18:47:10.294 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  80  FAILED    PSF        command.setInstrumentOffsets                                  Thu Jan  1 18:47:10.267 2009  to  Thu Jan  1 18:47:10.532 2009   (  0.26) secs
                    right PSF SetInstrumentOffsets started
                    left PSF SetInstrumentOffsets failed

  81  FAILED    IIF        command.moveFocus                                             Thu Jan  1 18:47:10.247 2009  to  Thu Jan  1 18:47:10.616 2009   (  0.37) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus failure for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus failure for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

  82  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:47:10.332 2009  to  Thu Jan  1 18:47:10.348 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  83  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:47:10.294 2009  to  Thu Jan  1 18:47:10.378 2009   (  0.08) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  84  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Jan  1 18:47:10.281 2009  to  Thu Jan  1 18:47:10.398 2009   (  0.12) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  85  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:47:26.332 2009  to  Thu Jan  1 18:47:26.332 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  86  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:47:26.368 2009  to  Thu Jan  1 18:47:26.368 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  87  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:49:29.594 2009  to  Thu Jan  1 18:49:43.080 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  88  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:49:29.560 2009  to  Thu Jan  1 18:49:43.058 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  89  FAILED    PSF        command.setInstrumentOffsets                                  Thu Jan  1 18:49:43.029 2009  to  Thu Jan  1 18:49:43.167 2009   (  0.14) secs
                    left PSF SetInstrumentOffsets failed

  90  FAILED    IIF        command.moveFocus                                             Thu Jan  1 18:49:43.007 2009  to  Thu Jan  1 18:49:43.215 2009   (  0.21) secs
                    IIF GetTrajectory command started for both LBC, start time 5.483307618055555e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus failure for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus failure for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

  91  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:49:43.080 2009  to  Thu Jan  1 18:49:43.100 2009   (  0.02) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  92  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:49:43.058 2009  to  Thu Jan  1 18:49:43.129 2009   (  0.07) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

  93  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Jan  1 18:49:43.043 2009  to  Thu Jan  1 18:49:43.147 2009   (  0.10) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

  94  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:49:54.658 2009  to  Thu Jan  1 18:49:54.658 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

  95  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:49:54.707 2009  to  Thu Jan  1 18:49:54.707 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

  96  FAILED    PSF        primaryMirror.command.adjustMirror                            Thu Jan  1 18:52:13.438 2009  to  Thu Jan  1 18:52:21.789 2009   (  8.35) secs
                    left PSF primary mirror force adjustments failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  97  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 18:52:13.691 2009  to  Thu Jan  1 18:52:21.723 2009   (  8.03) secs
                    left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  98  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 18:52:13.662 2009  to  Thu Jan  1 18:52:21.770 2009   (  8.11) secs
                    left PSF primary mirror chaseStop started
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase failed to make tolerance

  99  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 19:19:38.575 2009  to  Thu Jan  1 19:19:43.946 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

 100  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 19:19:38.679 2009  to  Thu Jan  1 19:19:43.988 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started

 101  FAILED    IIF        command.moveFocus                                             Thu Jan  1 19:19:43.747 2009  to  Thu Jan  1 19:19:44.168 2009   (  0.42) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus failure for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus failure for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

 102  FAILED    PSF        command.setInstrumentOffsets                                  Thu Jan  1 19:19:43.887 2009  to  Thu Jan  1 19:19:44.094 2009   (  0.21) secs
                    left PSF SetInstrumentOffsets failed

 103  FAILED    PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 19:19:43.946 2009  to  Thu Jan  1 19:19:44.052 2009   (  0.11) secs
                    right PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future
                    left PSF primary mirror adjustMirrorCollimation for 0 seconds in the future failed because left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 104  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Jan  1 19:19:43.911 2009  to  Thu Jan  1 19:19:44.073 2009   (  0.16) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 105  FAILED    PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 19:19:43.988 2009  to  Thu Jan  1 19:19:44.006 2009   (  0.02) secs
                    right PMC Mirror GoToPositionAbs Command Started
                    left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE

 106  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 19:19:47.235 2009  to  Thu Jan  1 19:19:47.235 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 107  FAILED    PMC        VxInterface.close                                             Thu Jan  1 19:19:47.261 2009  to  Thu Jan  1 19:19:47.261 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 108  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 19:19:50.721 2009  to  Thu Jan  1 19:19:50.721 2009   (  0.00) secs
                    Complete event but no Started event
                    left PMC Mirror GoToPositionAbs Command Complete

 109  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 19:19:50.750 2009  to  Thu Jan  1 19:19:50.750 2009   (  0.00) secs
                    Complete event but no Started event
                    left PSF primary mirror adjustMirrorCollimation complete for 0 seconds in the future

 110  FAILED    PMC        thermal.badReceive                                            Thu Jan  1 19:19:51.336 2009  to  Thu Jan  1 19:19:51.336 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 111  FAILED    PMC        VxInterface.packetReadError                                   Thu Jan  1 19:19:51.320 2009  to  Thu Jan  1 19:19:51.320 2009   (  0.00) secs
                    left PMC Thermal packet read error: 5002

 112  FAILED    PMC        VxInterface.selectTimeout                                     Thu Jan  1 19:19:51.305 2009  to  Thu Jan  1 19:19:51.305 2009   (  0.00) secs
                    left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 113  SEQERROR  PMC        mirror.command.goToPosition.absolute                          Thu Jan  1 19:35:57.383 2009  to  Thu Jan  1 19:36:16.665 2009   (  0.00) secs
                    Started event but no Complete event
                    left PMC Mirror GoToPositionAbs Command Started

 114  SEQERROR  PSF        primaryMirror.command.adjustMirrorCollimation                 Thu Jan  1 19:35:57.356 2009  to  Thu Jan  1 19:36:16.640 2009   (  0.00) secs
                    Started event but no Complete event
                    left PSF primary mirror adjustMirrorCollimation started for 0 seconds in the future

 115  FAILED    PSF        command.setInstrumentOffsets                                  Thu Jan  1 19:36:16.599 2009  to  Thu Jan  1 19:36:16.751 2009   (  0.15) secs
                    right PSF SetInstrumentOffsets started
                    left PSF SetInstrumentOffsets failed

 116  FAILED    IIF        command.moveFocus                                             Thu Jan  1 19:36:16.578 2009  to  Thu Jan  1 19:36:16.831 2009   (  0.25) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus failure for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus failure for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

 117  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Jan  1 19:36:16.617 2009  to  Thu Jan  1 19:36:16.728 2009   (  0.11) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 118  SEQERROR  PCS        telescope.command.startTracking                               Thu Jan  1 19:43:35.322 2009  to  Thu Jan  1 19:55:28.261 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 119  SEQERROR  PCS        telescope.command.startTracking                               Thu Jan  1 19:43:35.591 2009  to  Thu Jan  1 19:43:35.591 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 120  FAILED    PSF        command.setInstrumentOffsets                                  Thu Jan  1 19:53:25.660 2009  to  Thu Jan  1 19:53:25.806 2009   (  0.15) secs
                    left PSF SetInstrumentOffsets failed

 121  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Thu Jan  1 19:53:25.675 2009  to  Thu Jan  1 19:53:25.786 2009   (  0.11) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 122  FAILED    IIF        command.moveFocus                                             Thu Jan  1 19:53:25.637 2009  to  Thu Jan  1 19:53:25.857 2009   (  0.22) secs
                    IIF GetTrajectory command started for both LBC, start time 5.483312042824074e+04, time 3.610000000000000e+02, interval 1.000000000000000e+00
                    IIF MoveFocus failure for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus failure for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

 123  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 19:57:32.796 2009  to  Thu Jan  1 19:57:32.796 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 124  FAILED    PMC        VxInterface.close                                             Thu Jan  1 19:57:32.825 2009  to  Thu Jan  1 19:57:32.825 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 125  FAILED    PMC        thermal.badReceive                                            Thu Jan  1 19:58:13.401 2009  to  Thu Jan  1 19:58:13.401 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 126  FAILED    PMC        VxInterface.packetReadError                                   Thu Jan  1 19:58:13.387 2009  to  Thu Jan  1 19:58:13.387 2009   (  0.00) secs
                    left PMC Thermal packet read error: 5002

 127  FAILED    PMC        VxInterface.selectTimeout                                     Thu Jan  1 19:58:13.369 2009  to  Thu Jan  1 19:58:13.369 2009   (  0.00) secs
                    left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 128  FAILED    PMC        VxInterface.close                                             Thu Jan  1 19:58:59.801 2009  to  Thu Jan  1 19:58:59.801 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 129  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 19:58:59.783 2009  to  Thu Jan  1 19:58:59.783 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 130  FAILED    PMC        VxInterface.close                                             Thu Jan  1 19:59:35.793 2009  to  Thu Jan  1 19:59:35.793 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 131  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 19:59:35.777 2009  to  Thu Jan  1 19:59:35.777 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 132  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 20:08:46.294 2009  to  Thu Jan  1 20:08:46.294 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 133  FAILED    PMC        VxInterface.close                                             Thu Jan  1 20:08:46.322 2009  to  Thu Jan  1 20:08:46.322 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 134  FAILED    PMC        VxInterface.close                                             Thu Jan  1 20:11:06.289 2009  to  Thu Jan  1 20:11:06.289 2009   (  0.00) secs
                    left PMC ServoLoop closing network connection

 135  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 20:11:06.274 2009  to  Thu Jan  1 20:11:06.274 2009   (  0.00) secs
                    left PMC ServoLoop length error: expected 544, got 96

 136  FAILED    PMC        VxInterface.close                                             Thu Jan  1 20:38:26.741 2009  to  Thu Jan  1 20:38:26.741 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 137  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 20:38:26.728 2009  to  Thu Jan  1 20:38:26.728 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 138  FAILED    PMC        VxInterface.close                                             Thu Jan  1 21:06:45.603 2009  to  Thu Jan  1 21:06:45.603 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 139  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 21:06:45.570 2009  to  Thu Jan  1 21:06:45.570 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 140  FAILED    PMC        VxInterface.close                                             Thu Jan  1 21:46:42.625 2009  to  Thu Jan  1 21:46:42.625 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 141  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 21:46:42.609 2009  to  Thu Jan  1 21:46:42.609 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 142  FAILED    PMC        thermal.badReceive                                            Thu Jan  1 21:50:44.006 2009  to  Thu Jan  1 21:50:44.006 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 143  FAILED    PMC        VxInterface.packetReadError                                   Thu Jan  1 21:50:43.991 2009  to  Thu Jan  1 21:50:43.991 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

 144  FAILED    PMC        VxInterface.selectTimeout                                     Thu Jan  1 21:50:43.975 2009  to  Thu Jan  1 21:50:43.975 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 145  FAILED    PMC        VxInterface.close                                             Thu Jan  1 22:01:50.890 2009  to  Thu Jan  1 22:01:50.890 2009   (  0.00) secs
                    left PMC Mirror closing network connection

 146  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 22:01:50.873 2009  to  Thu Jan  1 22:01:50.873 2009   (  0.00) secs
                    left PMC Mirror length error: expected 92, got 96

 147  FAILED    PMC        VxInterface.close                                             Thu Jan  1 22:03:44.073 2009  to  Thu Jan  1 22:03:44.073 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

 148  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 22:03:44.056 2009  to  Thu Jan  1 22:03:44.056 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

 149  SEQERROR  PCS        telescope.command.startTracking                               Thu Jan  1 22:04:09.709 2009  to  Thu Jan  1 22:47:56.147 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 150  SEQERROR  PCS        telescope.command.startTracking                               Thu Jan  1 22:04:09.979 2009  to  Thu Jan  1 22:04:09.979 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 151  FAILED    PMC        VxInterface.close                                             Thu Jan  1 22:15:14.068 2009  to  Thu Jan  1 22:15:14.068 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 152  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 22:15:14.052 2009  to  Thu Jan  1 22:15:14.052 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 153  FAILED    PMC        VxInterface.close                                             Thu Jan  1 22:34:13.597 2009  to  Thu Jan  1 22:34:13.597 2009   (  0.00) secs
                    left PMC Hardpoint closing network connection

 154  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 22:34:13.580 2009  to  Thu Jan  1 22:34:13.580 2009   (  0.00) secs
                    left PMC Hardpoint length error: expected 304, got 96

 155  SEQERROR  PCS        telescope.command.startTracking                               Thu Jan  1 22:47:56.147 2009  to  Thu Jan  1 22:57:49.926 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 156  SEQERROR  PCS        telescope.command.startTracking                               Thu Jan  1 22:47:56.415 2009  to  Thu Jan  1 22:47:56.415 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 157  SEQERROR  PCS        telescope.command.startTracking                               Thu Jan  1 22:57:49.926 2009  to  Thu Jan  1 23:30:33.539 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 158  SEQERROR  PCS        telescope.command.startTracking                               Thu Jan  1 22:57:50.195 2009  to  Thu Jan  1 22:57:50.195 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 159  FAILED    PMC        VxInterface.close                                             Thu Jan  1 22:58:32.073 2009  to  Thu Jan  1 22:58:32.073 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 160  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 22:58:32.054 2009  to  Thu Jan  1 22:58:32.054 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 161  FAILED    PMC        VxInterface.close                                             Thu Jan  1 23:08:37.786 2009  to  Thu Jan  1 23:08:37.786 2009   (  0.00) secs
                    left PMC Mirror closing network connection

 162  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 23:08:37.769 2009  to  Thu Jan  1 23:08:37.769 2009   (  0.00) secs
                    left PMC Mirror length error: expected 92, got 96

 163  FAILED    PMC        VxInterface.close                                             Thu Jan  1 23:15:59.022 2009  to  Thu Jan  1 23:15:59.022 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 164  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 23:15:59.003 2009  to  Thu Jan  1 23:15:59.003 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 165  FAILED    PMC        VxInterface.close                                             Thu Jan  1 23:23:57.648 2009  to  Thu Jan  1 23:23:57.648 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 166  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 23:23:57.631 2009  to  Thu Jan  1 23:23:57.631 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 167  FAILED    PMC        VxInterface.close                                             Thu Jan  1 23:33:21.555 2009  to  Thu Jan  1 23:33:21.555 2009   (  0.00) secs
                    right PMC Actuator closing network connection

 168  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 23:33:21.538 2009  to  Thu Jan  1 23:33:21.538 2009   (  0.00) secs
                    right PMC Actuator length error: expected 152, got 96

 169  SEQERROR  PCS        telescope.command.startTracking                               Thu Jan  1 23:50:43.813 2009  to  Fri Jan  2 00:21:39.574 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 170  SEQERROR  PCS        telescope.command.startTracking                               Thu Jan  1 23:50:44.081 2009  to  Thu Jan  1 23:50:44.081 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 171  FAILED    PMC        VxInterface.lengthError                                       Thu Jan  1 23:59:19.712 2009  to  Thu Jan  1 23:59:19.712 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 172  FAILED    PMC        VxInterface.close                                             Thu Jan  1 23:59:19.729 2009  to  Thu Jan  1 23:59:19.729 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 173  FAILED    PMC        VxInterface.close                                             Fri Jan  2 00:12:49.704 2009  to  Fri Jan  2 00:12:49.704 2009   (  0.00) secs
                    left PMC Actuator closing network connection

 174  FAILED    PMC        VxInterface.lengthError                                       Fri Jan  2 00:12:49.690 2009  to  Fri Jan  2 00:12:49.690 2009   (  0.00) secs
                    left PMC Actuator length error: expected 152, got 96

 175  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 00:21:39.574 2009  to  Fri Jan  2 00:44:01.410 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 176  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 00:21:39.843 2009  to  Fri Jan  2 00:21:39.843 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 177  FAILED    PMC        VxInterface.lengthError                                       Fri Jan  2 00:27:10.561 2009  to  Fri Jan  2 00:27:10.561 2009   (  0.00) secs
                    right PMC PMC length error: expected 32, got 96

 178  FAILED    PMC        VxInterface.close                                             Fri Jan  2 00:27:10.613 2009  to  Fri Jan  2 00:27:10.613 2009   (  0.00) secs
                    right PMC PMC closing network connection

 179  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 01:43:55.295 2009  to  Fri Jan  2 01:46:11.161 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 180  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 01:43:55.562 2009  to  Fri Jan  2 01:43:55.562 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 181  FAILED    IIF        command.preset.(TRACK)                                        Fri Jan  2 01:50:11.247 2009  to  Fri Jan  2 01:50:17.847 2009   (  6.60) secs
                    IIF GetTrajectory command started for both LBC, start time 5.483336820601852e+04, time 3.480000000000000e+02, interval 1.000000000000000e+00
                    IIF Preset failure for both LBC mode TRACK: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF Preset failure for both LBC mode TRACK: right PMC Mirror GoToPositionAbs Command Complete
                    IIF Preset command failed for both LBC mode TRACK from IIF

 182  FAILED    PMC        thermal.badReceive                                            Fri Jan  2 01:59:27.881 2009  to  Fri Jan  2 01:59:27.881 2009   (  0.00) secs
                    left PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 183  FAILED    PMC        VxInterface.packetReadError                                   Fri Jan  2 01:59:27.862 2009  to  Fri Jan  2 01:59:27.862 2009   (  0.00) secs
                    left PMC Thermal packet read error: 5002

 184  FAILED    PMC        VxInterface.selectTimeout                                     Fri Jan  2 01:59:27.839 2009  to  Fri Jan  2 01:59:27.839 2009   (  0.00) secs
                    left PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 185  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 02:08:27.831 2009  to  Fri Jan  2 02:18:20.348 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 186  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 02:08:28.103 2009  to  Fri Jan  2 02:08:28.103 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 187  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 02:44:39.318 2009  to  Fri Jan  2 03:16:43.271 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 188  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 02:44:39.585 2009  to  Fri Jan  2 02:44:39.585 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 189  FAILED    PMC        VxInterface.selectTimeout                                     Fri Jan  2 03:15:47.617 2009  to  Fri Jan  2 03:15:47.617 2009   (  0.00) secs
                    right PMC Thermal select timed out with bytes to receive = 416, buffer size = 432

 190  FAILED    PMC        thermal.badReceive                                            Fri Jan  2 03:15:47.648 2009  to  Fri Jan  2 03:15:47.648 2009   (  0.00) secs
                    right PMC mirror ventilation setpoint: bad receive from thermal computer, error is pmc.vxWorks.message.receive.timedout

 191  FAILED    PMC        VxInterface.packetReadError                                   Fri Jan  2 03:15:47.632 2009  to  Fri Jan  2 03:15:47.632 2009   (  0.00) secs
                    right PMC Thermal packet read error: 5002

 192  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 03:16:43.271 2009  to  Fri Jan  2 03:45:11.802 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 193  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 03:16:43.540 2009  to  Fri Jan  2 03:16:43.540 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 194  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 04:13:46.331 2009  to  Fri Jan  2 04:43:50.869 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS will start tracking target

 195  SEQERROR  PCS        telescope.command.startTracking                               Fri Jan  2 04:13:46.606 2009  to  Fri Jan  2 04:13:46.606 2009   (  0.00) secs
                    Complete event but no Started event
                    - Seconds of wait: 2.5000000e-01.

 196  FAILED    PSF        command.setInstrumentOffsets                                  Fri Jan  2 04:44:45.929 2009  to  Fri Jan  2 04:44:46.112 2009   (  0.18) secs
                    left PSF SetInstrumentOffsets failed

 197  FAILED    IIF        command.moveFocus                                             Fri Jan  2 04:44:45.896 2009  to  Fri Jan  2 04:44:46.218 2009   (  0.32) secs
                    IIF MoveFocus command started for right LBC for -8.000000000000000e-01
                    IIF MoveFocus failure for left LBC: left PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus failure for left LBC: left PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for left LBC for -8.000000000000000e-01

 198  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Jan  2 04:44:45.964 2009  to  Fri Jan  2 04:44:46.092 2009   (  0.13) secs
                    left PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 199  FAILED    PSF        command.setInstrumentOffsets                                  Fri Jan  2 04:44:46.177 2009  to  Fri Jan  2 04:44:46.510 2009   (  0.33) secs
                    right PSF SetInstrumentOffsets failed

 200  FAILED    IIF        command.moveFocus                                             Fri Jan  2 04:44:46.157 2009  to  Fri Jan  2 04:44:46.562 2009   (  0.41) secs
                    IIF MoveFocus failure for right LBC: right PMC Mirror GoToPositionAbs Command Failed because Chase state not IDLE
                    IIF MoveFocus failure for right LBC: right PSF SetInstrumentOffsets failed
                    IIF MoveFocus command failed for right LBC for -8.000000000000000e-01

 201  FAILED    PSF        primaryMirror.command.setLocalOffsets                         Fri Jan  2 04:44:46.206 2009  to  Fri Jan  2 04:44:46.479 2009   (  0.27) secs
                    right PSF primary mirror setLocalOffsets failed because Primary mirror collimation failed

 202  SXDXBOTH  PCS        telescope.command.listPMTerms                                 Fri Jan  2 05:24:43.805 2009  to  Fri Jan  2 05:24:43.813 2009   (  0.01) secs
                    

 203  SEQERROR  IIF        command.offset                                                Fri Jan  2 06:56:47.359 2009  to  Fri Jan  2 06:56:47.383 2009   (  0.00) secs
                    Started event but no Complete event
                    IIF Offset command started for both LBC from IIF

 204  SEQERROR  IIF        command.offset                                                Fri Jan  2 06:56:47.383 2009  to  Fri Jan  2 06:56:47.408 2009   (  0.00) secs
                    Started event but no Complete event
                    IIF Offset command started for both LBC from IIF

 205  SEQERROR  PCS        telescope.command.offsetTelescopeEquatorial                   Fri Jan  2 06:56:47.445 2009  to  Fri Jan  2 06:56:47.460 2009   (  0.00) secs
                    Started event but no Complete event
                    PCS set offset equatorial started with delta RA = -1.668001469857359e-04, delta DEC = -4.462225120932169e-05

 206  SEQERROR  PCS        telescope.command.offsetTelescopeEquatorial                   Fri Jan  2 06:56:48.007 2009  to  Fri Jan  2 06:56:48.007 2009   (  0.00) secs
                    Complete event but no Started event
                    PCS set offset equatorial complete with delta RA = -1.668001469857359e-04, delta DEC = -4.462225120932169e-05

 207  SEQERROR  IIF        command.offset                                                Fri Jan  2 06:57:21.885 2009  to  Fri Jan  2 06:57:21.885 2009   (  0.00) secs
                    Complete event but no Started event
                    IIF Offset command complete for both LBC from IIF

 208  SEQERROR  IIF        command.offset                                                Fri Jan  2 06:57:22.190 2009  to  Fri Jan  2 06:57:22.190 2009   (  0.00) secs
                    Complete event but no Started event
                    IIF Offset command complete for both LBC from IIF

 209  SHUTDOWN  PCS        shutdown                                                      Fri Jan  2 07:40:43.746 2009  to  Fri Jan  2 07:40:43.746 2009   (  0.00) secs
                    PCS subsystem shut down - PCS Version 3.28f

 210  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 07:40:44.105 2009  to  Fri Jan  2 07:40:44.105 2009   (  0.00) secs
                    There have been no EL track polys for 1.000000000000000e+00 .

 211  FAILED    MCS.MCSPU  MCSPU.Tracker.polyStop                                        Fri Jan  2 07:40:44.126 2009  to  Fri Jan  2 07:40:44.126 2009   (  0.00) secs
                    There have been no AZ track polys for 1.000000000000000e+00 .

 212  STARTUP   PCS        startup                                                       Fri Jan  2 07:41:00.254 2009  to  Fri Jan  2 07:41:00.254 2009   (  0.00) secs
                    PCS subsystem started - PCS Version 3.28e

**********************************************************
    Reporting period ending:   Fri Jan  2 07:52:58.427 2009
********************************************************************************************************
Topic revision: r2 - 06 Oct 2009, NormCushing
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback