Software Release Notes for Build "20"

Release Date: Feb 5, 2009
Generic Release Name: B20
Public Release Name: TCS Testing/Lucifer Com

Specific Tests that need to be performed with the Telescope

Patches to the Release

  • none.

Known Bugs

  • none.

Release Overview

  • This release is built from Build 18 with additions for just the PSF and IIF.

Operating System, System Configuration, TCS and Hardware Computers

TCS Servers / Workstations

  • none.

agw-control computer

  • none.

jet computer, DSP, FPGA

  • none.

Networks

  • none.

PLCs

  • none.

TCS Subsystems and GUIs, and significant configuration files

lbt.conf

  • none.

AGw control server

  • none.

AOS - Adaptive Optics

  • none.

ECS - Enclosure Control

  • none.

ENV - Environmental Sensors

  • none.

IIF / IRS - Instrument Interface

  • IIF Version 5.22
    This version has improved secondary active optics offloading for both the Preset and OffsetPointing commands. The needed offload values are calculated at the start of the command, and then applied with mirror collimation at the end of the command.

GCS - Guiding Control - V2.0.10

  • fixed a very old bug deep in the CamImage class that caused the last pixel of an image to get lost when transferred through CommonSW. This caused some funny effects when visualizing the acquisition and guide images in GCS GUI which appeared to never have the contrast just right. Now they have.
  • Also fixed the problem with the GUI not showing an acquisition image when no guide star was found and the window showing the full CCD readouts doesn't steal the focus anymore as it just stays open as long as the GUI is running.
  • added GCS.delayVerification to lbt.conf to dynamically control if GCS matches the guide rate in star verification phase
  • added code to support the lbt.conf::GCS.delayVerification flag
  • added additional syslog messages to detect computing times for different stages in guiding and WFS loop
  • fixed a problem with logging the actual delay in the guide loop to match guide rate
  • fixed a problem with not bypassing the seconds of delay in guide loop if asked to not match guide rate by delaying
  • added accuracy to the guide loop delay to better match the requested guide rate

LSS - Logging and Events

  • none.

MCS / mcstemp - Mount Control

  • MCSPU was changed to adapt to new DSP servo code. The MCSPU now reads the time-to-completion for a slew back from the DSP and stays in a "SLEW" state until the DSP indicates the slew is complete. This is mostly for the operator's benefit.
  • MCSPU now performs more thorough verification tests on each tracking polynomial that it receives and logs detailed information when any problems are found.
  • The handling of MCSPU log files has changed. The files are now stored in the ~telescope/mcspuLogs/ directory on jet. Their name format has changed. It now reflects the date, hour and minute when they were created (as in yymmdd.hhmm). Old log files are no longer ever deleted by MCSPU. We'll probably eventually make a chron task that removes them when they're a year old, but at present the program never deletes a log file.

OSS - Optical Support

  • none.

PCS - Pointing Control

  • PCS_Version-3.30b
    • Modified two files for additional diagnostic information.
    • Please see Release Notes for Build 18 for changes to PCS since the last Lucifer Commissioning run.

PCS GUI

  • none.

Preset GUI

  • none.

Pointing Kernel / Pointing Kernel tools

  • none.

PMC - Primary Mirror Cell

  • none.

PSF - Point Spread Function

  • PSF Version 4.30
    This version supports splitting secondary active optics offloading into two parts: the first part is just a calculation without any changes to the mirrors, and the second part is the following collimation where the changes are applied. This supports IIF V 5.22.

SDB - Star Database

  • none.

TCS GUI

  • none.

WX - Weather Station

  • none.

TCS Common Software

commandreturn - client command status returns

  • none.

commandsequencer - client/subsystem command handling

  • none.

core - foundation routines

  • none.

datadictionary - reflective memory and event support

  • none.

eventhandler - event handling

  • none.

networkconfig - subsystem management

  • none.

reflectivememory - global shared memory

  • none.

rpc - communication protocol

  • none.

setvalue - reflective memory access

  • none.

tcs_config - tcs configuration

  • none.

TCS Tools

DDEditor - Data Dictionary Editor

  • none.

DDBrowser - Data Dictionary Browser

  • none.

DDViewer - Data Dictionary Viewer

  • none.

Event Editor

  • none.

Telemetry

Collector

  • none.

Instruments and Environmental Sensors

DIMM - Differential Image Monitor

  • none.

idl

  • none.

iraf

  • none.

IRC - Infrared Test Camera Client

  • none.

LBC - LBT Binocular Camera

  • none.

LBTO Weather Station - 3DWGUI

  • none.

MAT - Mount Axillary Telescope

  • none.

Polaris Monitor

  • none.

-- NormCushing - 04 Feb 2009
Topic revision: r8 - 06 Oct 2009, NormCushing
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback