Prev Next

SW&IT Meeting Minutes 2019-09-30

Attendees: Andrew, Carl, David, Igor, Matthieu, Yang

Outlook

Labor Reporting

Report auto-generated every Monday at 6:30am, Do not edit this table, Update your entries in smartsheets.

20190923
LR20190923 - Bec, Matthieu 40.0
LR20190923 - Holmberg, Carl 40.0
LR20190923 - Colson, Andrew 40.0
LR20190923 - Edmeades, David 40.0
LR20190923 - Sola, Igor 0.0
LR20190923 - Kubanek, Petr 0.0
LR20190923 - Hooper, Stephen 0.0
LR20190923 - Zhang, Yang 40.0
LR20190923 - Zhang, Xianyu 40.0

News from management

Previous Action Items

Open topics

  • Argos lgs-sx BCU comms, new NIC
  • Argos BIOS boot on power on
  • LUCI $HOME space
  • MODS electronics cabinet breaker vs network

Team reports

PK

  • IT5140 - GUI fixes (Mount/Rotator details expansion/shrinking while adding/removing confirmation entries)
  • started work on abort for TCS subsystems (IT 7861)
  • vacation Tue - Fri
  • monitored observatory restart on Friday
next:

DE

  • Summit power cut prep and execution
    • Shutdown mostly smooth
    • Some machines had issues with key login. Kerberos?
    • Startup needs work both in power and mounts
    • UPS battery level not trustworthy; will investigate recalibration options
    • Full post-mortem this week
  • JPH computer arrived, will sort out this week
  • User accounts
  • ARGOS desktop computer power on behavior
  • Elliot power supply deliver

XZ

Last week:
  • Analyze the cause of the dump file
  • Intall and test the new fast diagnostic process on AdSec
  • Meeting about data storage structure
  • Write and send detach magnet and jumping actuator documents to Guido
  • Change configuration files for LBTI SX WFS new computer
  • ASM shutdown and restart
This two week:
  • vacation

AC

  • Support for AGW4 alignment
  • ARGOS planning meeting
  • Shutdown restart
    • Weather station - "ie_Open - device already" popup window indicating not all the data was being sent. Restarting the pc fixed this. Documented in wiki.
    • FacSum on middle display in rm507 was not showing new radar image. Fixed by reinstalling the lbto-tcsweb rpm.
    • FacSum on middle display on mountain was displaying "label_34". Restarting facsum.sh did not fix. Neither did reinstalling rpm. Restarting the NUC fixed issued. Updated IT7831.
  • OAC Telemetry
    • code cleanup - removed obsolete refmem entries
next
  • IT7882 - FacSum not showing guider or wfs images
  • IT7883 - "AGW1: Axes had not been homed, yet" while sending presets
  • IT7876 - "Failed to communicate with UMAC." Priority raised to medium.
  • OAC telemetry
    • TCS RPC commands

YZ

  • AO-Cravat:
    • Completed draft POI and a separate design document (waiting for Al to comment on them).
    • Next to spend some time on plotly.js.
  • LBC/MODS:
    • LBC non-sidereal guiding problems (IT#7847), found the cause, planning on a temporary fix (long term fix would be to rewrite the non-sidereal guiding for LBC, currently planned on letting users able to tweak some parameters to get around the problem if it occurs, but still need to change LBC code and release a new version).
    • Need to understand more on what needs to be added to the LBC fits keyword.
    • Working on post processing LBC telemetry data.
    • MODS power on had some glitches on Friday. Worked with Olga and finally all came back on successfully and we were able to take data as well. (It appears that the power outage on Friday tripped the MODS IEB/LLB breakers and they had to be reset. M2.BC initially also had some problems booting up, but become okay after the breakers reset. Also had to run fitsflush to get MODS images off to /newdata mount).

MB

  • OC, WPC, Management
  • 20190927 power shutdown/restart
  • ARGOS BCU comms and followup with WG
  • DMS
    • alta iterations
    • m1 surf WIP
  • PEPSI telecon and way forward
next
  • ALTA zoom
  • AO data
  • m1 surf

CH

Last week:
  • CHAOS: Reviewed additional current alert clients, LUCI1monitor, watch4dew, lbccontrol loggers, Zabbix.
    • Stats server Zabbix log says it forwards some warnings and errors to ALH.
    • ARGOS uses a local Zabbix only for diagnostic graphs of laser-related activity. ALH integration is a to-do.
    • Reviewed current ALH config files for lists of monitored devices/activities.
    • LBC, per YZ, uses tcl/tk cron jobs on lbccontrol.
    • AO, per XZ, already uses ALH.
  • SupportScripts:
    • Reviewed JH's desires beyond mere Python 3 compatibility.
    • Example: would like RB_Science.py dwell time between dir list updates below 1s. See if there's a way for DS9/XPA to support faster update rate.
    • Script really needs the 1s sleep between frames for DS9 to be ready, otherwise DS9 freezes or crashes in short order.

This week:
  • CHAOS: Finish non-ALH alert review and research alternative alert collection alternatives.
  • DMS: Discussed potential Monnit plot modifications with PG. Will review with MB.
  • SupportScripts: Review test results w/ JH and suggest modernization solutions.

IS

Last week:

  • OT
    • Document describing Calibration usage in the XSLT
    • Proposal Table
    • clean proposal table, possibly find out the ones that were approved? * add title to table

This week:
  • OT
    • LBC calibration header
    • LUCI ARC off lamps
    • Work on the xml2list to add new fields (late this week)
    • Work on csv file for the archive people — two versions — one with all the proposals from start of PIT and one for 2019B.
    • Work on point release that includes new functionality to allow warnings with script generation instead of just errors

  • LUCI
    • add to git /usr/local/binluci_geirs# where # is 1 or 2.
    • look at RTD MOS tab error calculation
Topic revision: r15 - 07 Oct 2019, IgorSola
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.