FACSUM Release Notes - Version 2.2d Released to Tucson and the mountain (28 April 2016)

  • The AO section is now displaying messages which match the AOSGUI. The AdSec entry maps to "Adaptive Secondary Status" and the WFS entry maps to "AO Status".
  • Fixed logic and data dictionary items used to populate the TCS action tabbed panel so the IIF, PCS, GCS, and AOS progress states are displayed properly.
  • Added logic to handle LUCI "number of exposures (N/M)" and "exposure time remaining (ExpoTime /ExpoTimeTotal)" akin to the LBC information.
  • For sidereal targets, hide the non-sidereal rate displays for LBTI as is done for the other instruments.
  • Reconciled/cleaned up the threshold values between the textual display and the color-coding of the graphics.
  • Implemented the color coding/status update for Presets, Offsets, and RunAO commands so the data properly reconciles with the data displayed on the IIF.
  • Remove display of the cursor.
  • Fixed labels to be clear or more useful and reconcile with GCSGUI.
  • Modified the logic for "rotator on source". Now using the rotator "in use" information" rather than the "all on source".
  • All nominal and warning states are foreground color on a black background. Only alarms have a red background.
  • Mount errors are colored depending upon the AZ or EL on source indicators.
  • Added reading of authorized focal station which will be needed to distinguish LUCIFER from LUCIFER/ARGOS.
  • Enlarged the severity condition indicators for the subsystems so they are more prominent.
  • Fixed the size of the AdSec and WFS entries to be the same as all the other AO or GCS entries.
  • Fixed some existing inconsistencies in the .ui in the way the SX and DX displays are defined and rendered.
  • Added debug flag to FACSUM.pro.
  • NEW: Display the telescope position angle.
  • NEW: When LBC is in use, display the LBC position angle.
  • NEW: Display the acquisition image in the "guider" image location before the guide images are obtained.
  • New data dictionary items being read which require an update to the wda.sh:
    • gcs.side[0|1].WFSCam.spotsFWHMMean
    • iif.LBC.side[0|1].positionAngle
    • pcs.monocularMode
    • pcs.side[0|1].pointingStatus.positionAngle
    • iif.side[0|1].pseudoMonocular
    • S_LUCIExpTimeRemaining
    • S_LUCINumberExposures
    • S_LUCISpareString1
    • S_LUCISpareString2
    • iif.side[0|1].COMMAND.subStatus[0,2,6,7]
    • iif.side[0|1].COMMAND.subColor[0,2,6,7]
    • mcs.spareInt[0], mcs.spareInt[1]
    • mcs.rotatorSide[0].rotators[2].trackerStateName
    • mcs.rotatorSide[0].rotators[5].trackerStateName
    • mcs.rotatorSide[1].rotators[2].trackerStateName
    • mcs.rotatorSide[1].rotators[5].trackerStateName
    • aos.side[0|1].ao.status
    • aos.side[0|1].adsec.status
    • aos.side[0|1].adsec.health
    • aos.side[0|1].flaow.ccdbin
    • aos.side[0|1].flaow.ccdfreq
    • aos.side[0|1].lbtiw.ccdbin
    • aos.side[0|1].lbtiw.ccdfreq
    • aos.side[0|1].ao.correctedmodes
    • mcs.azDrive.azOnlyOnSource
    • mcs.elDrive.elOnlyOnSource
    • mcs.rotatorSide[0].rotators[2].rotOnSource
    • mcs.rotatorSide[0].rotators[5].rotOnSource
    • mcs.rotatorSide[1].rotators[2].rotOnSource
    • mcs.rotatorSide[1].rotators[5].rotOnSource