Update Pointing Reference test for LUCI
Observations testing the UpdatePointingReference functionality in TCS Michele confirmed that the "absorb" buttons on the PCS GUI execute the updates, so the OSA can do the update (absorb) manually.
There are nine sub-tests that need to be done to demonstrate complete functionality of the UpdatePointingReference command:
1) REL Offset(s) in this coord system:
RADEC DETXY BOTH
2) Absorb RADEC I II III
in this
coord
system: DETXY IV V VI
BOTH VII VIII IX
3) Test: execute a dither pattern using ABS offsets in either of the two
coordinate systems (RADEC or DETXY) and note the results. The expectations:
Test sequence for each block
- Manual preset to BS91XX star, use a PA not at one of the cardinal directions (0,90,180,270) to differentiate between an RADEC and DETXY dice5 pattern. PA=20 would be OK.
- Execute off_RD_rel and/or off_XY_rel as needed (see details below)
- Ask OSA to "absorb" one or both as needed for test (see details below)
- Execute dice5_RD and/or dice5_XY as needed (see details below)
- Scripts reside in ~/LBTO/SciencePrep/zeroBase
Tests I, II, III show that RADEC absorbs only affect RADEC offsets
I] REL/RADEC offset followed by RADEC absorb.
- ABS/RADEC offsets work as expected around this position
- ABS/DETXY offsets work as expected around this position
- off_RD_rel
- absorb RADEC
- dice5_RD_abs
- dice5_XY_abs
- DATA:
II] REL/DETXY offset (like shift image) followed by RADEC absorb.
- ABS/RADEC offsets work as expected around this position
- ABS/DETXY offsets will undo the REL offsets from before
- off_XY_rel
- absorb RADEC
- dice5_RD_abs
- dice5_XY_abs
- DATA:
III] REL/RADEC & REL-DETXY offsets followed by RADEC absorb.
- ABS/RADEC offsets work as expected around this position
- ABS/DETXY offsets will undo the REL offsets from before
- off_XY_rel & off_RD_rel
- absorb RADEC
- dice5_RD_abs
- dice5_XY_abs
- DATA:
Tests IV, V, VI show that DETXY absorbs only affect DETXY offsets
IV] REL/RADEC offset followed by DETXY absorb.
- ABS/RADEC offsets will undo the REL offsets from before
- ABS/DETXY offsets work as expected around this position
- off_RD_rel
- absorb DETXY
- dice5_XY_abs
- dice5_RD_abs
- DATA:
V] REL/DETXY offset followed by DETXY absorb.
- ABS/RADEC offsets work as expected around this position
- ABS/DETXY offsets work as expected around this position
- off_XY_rel
- absorb DETXY
- dice5_RD_abs
- dice5_XY_abs
- DATA:
VI] REL/RADEC & REL-DETXY offsets followed by DETXY absorb.
- ABS/RADEC offsets will undo the REL offsets from before
- ABS/DETXY offsets work as expected around this position
- off_XY_rel & off_RD_rel
- absorb DETXY
- dice5_XY_abs
- dice5_RD_abs
- DATA:
Tests VII, VIII, IX show that offsets and absorbs can be combined
VII] REL/RADEC offset followed by DETXY & RADEC absorbs.
- ABS/RADEC offsets work as expected around this position
- ABS/DETXY offsets work as expected around this position
- off_RD_rel
- absorb RADEC & absorb DETXY
- dice5_RD_abs
- dice5_XY_abs
- DATA:
VIII] REL/DETXY offset followed by DETXY & RADEC absorbs.
- ABS/RADEC offsets work as expected around this position
- ABS/DETXY offsets work as expected around this position
- off_XY_rel
- absorb RADEC & absorb DETXY
- dice5_RD_abs
- dice5_XY_abs
- DATA:
IX] REL/RADEC & REL_DETXY offsets followed by DETXY & RADEC absorbs.
- ABS/RADEC offsets work as expected around this position
- ABS/DETXY offsets work as expected around this position
- off_RD_rel & off_XY_rel
- absorb RADEC & absorb DETXY
- dice5_RD_abs
- dice5_XY_abs
- DATA:
--
DavidThompson - 08 May 2011