INAF queue observing, 2023 Feb 27 - Feb28

Observer: Olga Kuhn
Telescope Operator: Josh Williams
Astronomers from Italy: Felice Cusano, Ester Marini, Andrea Rossi, Simona Paiano
Instrument: LUCI

Summary

These observations have been performed by LBT Italian observers connected from Italy with the support of LBTO personnel.
At the sunset the sky is clear, the wind is at the limit, we can open. We had to close for high wind at 8:00 UT.
We open again at 11:00. Some problems during the night with the LUCI1 guider.

Night duration (12 degree - twilight) 02:10 - 12:40 UT = * 10h* * 30m*
Observing time: 6 h 33 min (62 %)*
Weather time loss: 3 h 03 min (29 %)*
Technical time loss: 0 h 54 min (9 %)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Telluric HD 22859 LUCI1-2 G200-zJspec     for Giannini
Giannini Gaia21bkw LUCI1-2 ima-J      
Giannini Gaia21bkw LUCI1-2 G200-zjspec      
Giannini Gaia21bkw LUCI1-2 G200-zjspec      
Telluric HD 42853 LUCI1-2 G200-zJspec     for Palazzi
Palazzi SLSN2020 LUCI1-2 G200-zjspec     star-r-17-J15
Piconcelli HIP62745 LUCI1-2 G200-zjspec      
Piconcelli J121549.81-003432.1 LUCI1-2 G200-zjspec 0.25h+0.25   Completed
Piconcelli J124551.44+010505.0 LUCI1-2 G200-zjspec 450s+450s   50% done !
Piconcelli J124551.44+010505.0 LUCI1-2 G200-zjspec     Remaining data - completed! !
Piconcelli HIP62745 LUCI1-2 G200-zjspec      
Detailed log by Ester, Felice, Andrea and Simona at this link: https://drive.google.com/file/d/1GEqRg9-CXR4brpNx2-r5gLvucmOsGj8H/view?usp=sharing

Summary of LUCI science files: https://drive.google.com/file/d/1yrkuKTO17-EsoLGvnhToBM1-Y7N5_81S/view?usp=sharing
Summary of LUCI calib files: https://drive.google.com/file/d/1Ko9aSEWBcusAmPFCHiT9uqbF5A6yV6Dl/view?usp=sharing

Summary of MODS calib files: https://drive.google.com/file/d/1DP8kZK7xC_QrMEhgkev8n-8_vWApQF_G/view?usp=sharing

INAF queue observing, 2023 Feb 28 - Mar 01

Observer: Olga Kuhn
Telescope Operator: S. Allanson
Astronomers from Italy: Felice Cusano, Ester Marini, Andrea Rossi and Simona Paiano
Instrument: LUCI

Summary

These observations have been performed by LBT Italian observers connected from Italy with the support of LBTO personnel. At sunset the cirrus and wind guts above 22 m/s force us to keep the dome closed.

Night duration (12 degree - twilight) 02:10 - 12:40 UT = * 10h* * 30m*
Observing time: 0 h 00 min (0%)*
Weather time loss: 10 h 30 min (100%)*
Technical time loss: 0 h 00 min (0%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calibrations   MODS1+2        
Calibrations   LUCI1+2        
             
             
             
Detailed log by Ester, Felice, Andrea and Simona at this link:

Summary of LUCI calib files: https://drive.google.com/file/d/1_ZLf67wMDYiPDitEQZ0XjbJTkcRuWfKE/view?usp=sharing

Summary of MODS calib files: https://drive.google.com/file/d/1XAI8AWSGB3-AvDGuACcB3z3W2X7u9gmd/view?usp=sharing

INAF queue observing, 2023 Mar 01 - Mar 02

Observer: Dave Thompson
Telescope Operator: S. Allanson
Astronomers from Italy: Felice Cusano, Ester Marini, Andrea Rossi and Simona Paiano
Instrument: LUCI

Summary

These observations have been performed by LBT Italian observers connected from Italy with the support of LBTO personnel.
At sunset the wind guts above 22 m/s and snow force us to keep the dome closed.

Night duration (12 degree - twilight) 02:10 - 12:40 UT = * 10h* * 30m*
Observing time: 0 h 00 min (0%)*
Weather time loss: 10 h 30 min (100%)*
Technical time loss: 0 h 00 min (0%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calibrations   LUCI1+2        
             
             
             
Detailed log by Ester, Felice, Andrea and Simona at this link:

Summary of LUCI calib files: https://drive.google.com/file/d/1jpTvCFw_z0EDmPvGu-PImn26khmtZx6Y/view?usp=sharing

INAF queue observing, 2023 Mar 02 - Mar 03

Observer: Dave Thompson
Telescope Operator: Steve Allanson
Astronomers from Italy: Felice Cusano, Ester Marini, Andrea Rossi, Simona Paiano
Instrument: LUCI

Summary

These observations have been performed by LBT Italian observers connected from Italy with the support of LBTO personnel.

At the sunset the sky seems clear, maybe a little but foggy, but the all sky camera is frozen and this prevents to have a real idea of the sky. In any case we have high humidity (above 90%) and wind gusts of 26 m/s. Steve Allanson sent an email declaring that we cannot open because the weather conditions prevents any safe roof access and a clear evaluation of the situation. We have to call the night!

Night duration (12 degree - twilight) 02:10 - 12:40 UT = * 10h* * 30m*
Observing time: 0 h 00 min (00 %)*
Weather time loss: 10 h 30 min (00 %)*
Technical time loss: 0 h 00 min (00 %)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Detailed log by Ester, Felice, Andrea and Simona at this link: https://drive.google.com/file/d/1nFNzEbLjGaiA2xXAEnHr6w4x_OuhZNSw/view?usp=sharing

INAF queue observing, 2023 Mar 03 - Mar 04

Observer: Dave Thompson
Telescope Operator: S. Allanson
Astronomers from Italy: Felice Cusano, Ester Marini, Andrea Rossi and Simona Paiano
Instrument: LUCI

Summary

These observations have been performed by LBT Italian observers connected from Italy with the support of LBTO personnel. At sunset there some cirrus but we can open.

Night duration (12 degree - twilight) 02:10 - 12:40 UT = * 10h* * 30m*
Observing time: 10 h 15 min (98%)*
Weather time loss: 0 h 00 min ( 0%)*
Technical time loss: 0 h 15 min ( 2%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Telluric HIP 39929 LUCI1+2 G210 H     for Grazian
Grazian SDSSJ0918 LUCI1+2 G210 H 3.7h/3.5h   we took 2 more exposure due to some clouds, seeing 0.8"-1"
Telluric HIP35818 LUCI1+2 G200 zj     for Piconcelli
Piconcelli J0947 LUCI1+2 G200 zj 0.5h/0.5h   seeing ~0.9"
Telluric HIP56736 LUCI1+2 G200 HK     for Piconcelli
Piconcelli J1025 LUCI1+2 G200 HK 1.5h/1.5h   seeing ~1" and stable
Telluric HIP50660 LUCI1+2 G210 K     for Grazian - taken two sets with different exposure times
Telluric HIP50660 LUCI1+2 G210 H     for Grazian - taken two sets with different exposure times
Grazian SDSSJ1110 LUCI1+2 G210 K 0.83h+0.83h   seeing ~0.8"
Grazian SDSSJ1110 LUCI1+2 G210 H 0.83h+0.83h luci1.20230304.0105.fits-luci1.20230304.0114.fits / luci2.20230304.0117.fits-luci2.20230304.0126.fits The science files have the OBJECT keyword as NOTARGET (without the target name) - seeing ~ 1.0"
Telluric HIP68868 LUCI1+2 G200 zj     for Piconcelli
Piconcelli J1513 LUCI1+2 G200 zj 0.25h+0.25h   seeing ~0.7"
Rossi GRB230205A MODS1+2 Dual grating 1h+1h   seeing ~0.7"
Standard HZ44 MODS1+2 Dual grating     for Rossi
Detailed log by Ester, Felice, Andrea and Simona at this link: https://drive.google.com/file/d/1gs-N7GA1E2X5-fqdIGaS5PhNlUabl2rP/view?usp=sharing

Summary of LUCI science files: https://drive.google.com/file/d/1K2c2WgAkAkvECmrcXg6GB77vTLwkvB3N/view?usp=sharing

Summary of MODS science files: https://drive.google.com/file/d/1K2c2WgAkAkvECmrcXg6GB77vTLwkvB3N/view?usp=sharing

INAF queue observing, 2023 Mar 04 - Mar 05

Observer: Dave Thompson
Telescope Operator: S. Allanson
Astronomers from Italy: Felice Cusano, Ester Marini, Andrea Rossi and Simona Paiano
Instrument: MODS, LUCI

Summary

These observations have been performed by LBT Italian observers connected from Italy with the support of LBTO personnel. At sunset the sky is clear, we can open, but the wind is at limit. During the night we stay closed for high wind for about 4.5 hours in total.

Night duration (12 degree - twilight) 02:10 - 12:40 UT = * 10h* * 30m*
Observing time: 5 h 45 min (55%)*
Weather time loss: 4 h 45 min ( 45%)*
Technical time loss: 0 h 0 min ( %)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Belladitta mods.9.j0309 MODS1-2 red grating 0.89h   stopped after 1 and 1/3 exposures for high wind
Giannini Gaia21bkw MODS1-2 dual grating 0.5h    
Decarli PSO182.77 MODS1-2 dual grating 0.33h    
Grazian SDSSJ1110 MODS1-2 dual grating 1.5h   stopped after 0.75 h for variable seeing (1"-2")
Standard G191-B MODS1-2 dual grating      
Standard Feige 34 MODS1-2 red grating      
Standard Hz44 MODS1-2 dual grating      
Piconcelli J1639 LUCI1-2 G200-HKspec 0.5h    
Piconcelli J1621 LUCI1-2 G200-HKspec 0.5h    
Telluric HIP87643 LUCI1-2 G200-HKspec      
Telluric HIP7002 LUCI1-2 G200-HKspec      

Detailed log by Ester, Felice, Andrea and Simona at this link: https://drive.google.com/file/d/1CmBmYxo-UcE1yHvgJUGKHuyXG3biYCMb/view?usp=sharing

Summary of LUCI science files: https://drive.google.com/file/d/1S-uZFRThaoH5ZzaXYnmChP7SO-mggnuS/view?usp=sharing

Summary of MODS science files: https://drive.google.com/file/d/1F4hRIrqRNZl0CUE5dnklCn8ZQ_k7c8vt/view?usp=sharing
Topic revision: r1 - 06 Mar 2023, FeliceCusano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback