INAF queue observing, 2022 July 04 - July 05

Observer: A. Cardwell
Telescope Operator: David Gonzalez Huerta
Astronomers from Italy: Simona Paiano, Ester Marini
Instrument: LBC

Summary

Due to the Covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (S. Paiano and E. Marini) connected from Italy.

At the sunset the sky is cloudly with 100% humidity.

Night duration (12 degree - twilight) 03:35 - 11:15 UT = 7 h 50 m
Observing time: 0h 0min (0%)*
Weather time loss: 7h 50min (100%)*
Technical time loss: 0h 0min (0%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calibration Severgnini MODS slit flat 0.8 dualgrating   Mods[1-2][b/r].20220705.0003-0008  
Calibration Severgnini MODS slitless dualgrating   Mods[1-2][b/r].20220705.0009 - mods[1-2]b.20220705.0018, mods[1-2]r.20220705.0013  
Calibration Severgnini MODS arc dualgrating   mods[1-2]b.20220705.0019-0021, mods[1-2]r.20220705.0014-0016  
Calibration Giannini MODS slit flat 0.8 dualgrating   mods[1-2]b.20220705.0022-0027, mods[1-2]r.20220705.0017-0022  
Calibration Giannini MODS slit flat 0.8 dualgrating   mods[1-2]b.20220705.0028-0037, mods[1-2]r.20220705.0023-0027  
Calibration Giannini MODS arcs_dual   mods[1-2]b.20220705.0038-0040, mods[1-2]r.20220705.0028-0030  
Detailed log by Andrew Cardwell at this link:

https://drive.google.com/drive/u/2/folders/1oS6irJ2i-GJnK-YpFLB7LWZPsm4tEf3t

Notes

INAF queue observing, 2022 July 05 - July 06

Observer: A. Cardwell
Telescope Operator: Josh Williams
Astronomers from Italy: Simona Paiano, Ester Marini
Instrument: LBC, PEPSI

Summary

Due to the Covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (S. Paiano and E. Marini) connected from Italy.

At the sunset the sky seemed clear and the humidity was below the limit, but soon the sky became covered.

Night duration (12 degree - twilight) 03:35 - 11:15 UT = 7 h 50 m
Observing time: 6h 20min (81%)*
Weather time loss: 1h 25min (18%)*
Technical time loss: 0h 5min (1%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calibration Flats LBC-Bino U-,V-spec, g, i     PA=0,180, for Giunta, Rossi
Rainer HAT-P-37 PEPSI CD1-4/300   20+30min each side S/N~45(blue), ~100(red) first, then ~31(blue), ~175(red) with a second exp of 30 min
Rainer HAT-P-37 PEPSI CD2-5/300   20min each side S/N~60 in the blue ~145 in the red
Rainer HAT-P-37 PEPSI CD3-6/300   30 min each side S/N~105 in the blue ~190 in the red, we added 10 minutes to the exp time to reach good S/N
Bellazzini GaiaEDR3 2659693686716034176 PEPSI CD3-6/300 15min each side   S/N~110 in the red and ~60 in the blue
Bellazzini GaiaEDR3 264267523528641952 PEPSI CD3-6/300 15min each side   S/N~85 in the red and ~75 in the blue
Bellazzini GaiaEDR3 2448812029433640704 PEPSI CD3-6/300 15min each side   S/N~80 in the red and ~50 in the blue
Clementini GaiaEDR3 1982512068675148032 PEPSI CD2-4/300 15min each side   S/N~112 in the red and ~36 in the blue (blue slightly below the requirement)
Giunta twilight field LBC-Bino   0.18+0.18h   2005TG45_20220706UT.xml (done twice + 6more images before the next target reached 30deg)
Giunta twilight field LBC-Bino   0.12+0.12h   2020SB_20220706.xml
Calibration Flats LBC-Bino r-sloan,z-sloan     PA=0,180
Detailed log by Andrew Cardwell at this link:

https://drive.google.com/file/d/1CakFv-kFIIh7JPGujr7oVw6nbzyySX6j/view?usp=sharing

Notes

INAF queue observing, 2022 July 06 - July 07

Observer: A. Cardwell
Telescope Operator: Josh Williams
Astronomers from Italy: Ester Marini, Simona Paiano
Instrument: MODS

Summary

Due to the Covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (E. Marini, S.Paiano, Andrea Rossi ) connected from Italy.

At sunset the sky is clear and the humidity is below the limit.
We plan to do a MODS night, in order to start and finish MiravalZanon ’s program.

Night duration (12 degree - twilight) 03:35 - 11:15 UT = 7 h 50 m
Observing time: 7h 22min (94%)*
Weather time loss: 0h 00min (0%)*
Technical time loss: 0h 28min (6%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
STD BD+332642 MODS-LS Dual Grating   mods1-2b.20220707.0003-0005.fits; mods1-2r.20220707.0006-0008 for MiravalZanon
MiravalZanon J1816 MODS-LS Dual Grating   mods1-2b.20220707.000-000.fits; mods1-2r.20220707.000-000 seeing~0.7-0.8" on the first six exposures, third hour: seeing stable ~0.6", fourth hour: seeing ~0.8", fifth hour = 0.9", sixth hour= we did first two exposures, the last one should be evaluated because taken after the 12-twelve twilight , last 30 mins: missing
Calibration MiravalZanon MODS arc_dualgrating,   mods[1-2]b.20220707.0025-0027, mods[1-2]r.20220712.0037-0039  
Calibration MiravalZanon MODS slit_flat_1.0_dualgrating,   mods[1-2]b.20220707.0028-033, mods[1-2]r.20220712.0040-0045  
Calibration MiravalZanon MODS slitless_flat_dualgrating,   mods[1-2]b.20220707.0034-0043, mods[1-2]r.20220712.0046-0050.  
Calibration MiravalZanon MODS slit_flat_5.0_dualgrating,   mods[1-2]b.20220707.0044-0049, mods[1-2]r.20220712.0051-0053  
Calibration MiravalZanon MODS Bias 8kx3k,   mods[1-2]b.20220707.0050-0054, mods[1-2]r.20220712.0054-0058.  
Detailed log by Andrew Cardwell at this link:

https://drive.google.com/file/d/13b5YzCYdReXJL0pJP3jAzY3A3CGMUaE7/view?usp=sharing

Notes

INAF queue observing, 2022 July 07 - July 08

Observer: A. Cardwell
Telescope Operator: Josh Williams
Astronomers from Italy: Simona Paiano, Ester Marini
Instrument: LBC and LUCI

Summary

Due to the Covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (S.Paiano, E. Marini and Andrea Rossi ) connected from Italy.

At sunset the sky seems clear. The forecast says mostly clear, but some clouds are visible from the all sky camera in the East part of the sky.

Night duration (12 degree - twilight) 03:35 - 11:15 UT = 7 h 50 m
Observing time: 5h 40min (72.3%)*
Weather time loss: 2h 00min (25.5%)*
Technical time loss: 0h 10min (2.2%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Giunta 2020HA10 LBC g + i     Seeing~1.0" , field observed two times
Rossi AT2022cmc LBC ugriz 0.35h+0.3h   Seeing~1.0"
Giunta KN_A - KN_B LBC g + i 0.46h+0.46h   Seeing~1.2"
Giunta AO_K - AO_L LBC g + i 0.27h+0.27h   Seeing~ 1.2"
CALIB Mannucci MODS1-2 slitless-dual   Mods[1-2]b.20220708.0009-0018, mods1r.20220708.0010-0014, mods2r.20220708.0009-0013  
CALIB Mannucci MODS1-2 arcs-dual   mods[1-2]b.20220708.0019-0021, mods[1-2]r.20220708.0014-0017  
Giunta twilight field LBC-Bino griz 0.083h+0.083h   2013TQ5, lbcr.20220708.103806.fits and lbcb.20220708.103816.fits are bad images
Giunta twilight field LBC-Bino griz 0.23h+0.23h   2020SB, done twice. Satellite trail in lbcr.20220708.105110, lbcb.20220708.105123, lbcr.20220708.105659 and lbcb.20220708.105708
Detailed log by Andrew Cardwell at this link:

https://drive.google.com/file/d/1mOdYR1k90cj5QZ0mLSBvlC08xZ_M6vlQ/view?usp=sharing

-- AndreaRossi - 10 Jul 2022

INAF queue observing, 2022 July 09 - July 10

Observer: A. Cardwell
Telescope Operator: Josh Williams
Astronomers from Italy: Andrea Rossi and Felice Cusano
Instrument: PEPSI

Summary

Due to the Covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers ( A. Rossi, F. Cusano, E. Marini and S. Paiano) connected from Italy.

At sunset the sky is cloudy, we stay closed.

Night duration (12 degree - twilight) 03:35 - 11:15 UT = 7 h 50 m
Observing time: 0h 0min (0%)*
Weather time loss: 7h 50min (100%)*
Technical time loss: 0h 0min (0%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
             
             
             
             
Detailed log by Andrew Cardwell at this link:

https://drive.google.com/file/d/132x-7cHB7m7vwi7qiA1tDd23klmOlMAC/view?usp=sharing

-- EsterMarini - 10 Jul 2022

INAF queue observing, 2022 July 10 - July 11

Observer: A. Cardwell
Telescope Operator: Josh Williams
Astronomers from Italy: Ester Marini and Felice Cusano
Instrument: PEPSI

Summary

Due to the Covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (S.Paiano, A. Rossi, Felice Cusano and E. Marini) connected from Italy.

At sunset the sky is cloudy and we cannot open.

Night duration (12 degree - twilight) 03:35 - 11:15 UT = 7 h 50 m
Observing time: 1h 3min (13.4%)*
Weather time loss: 6h 17min (80.2%)*
Technical time loss: 0h 30min (6.4%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Bellazzini Gaia EDR3 1250349199880144640 PEPSI CD3-6/300     to redo
Rainer Kepler-6 PEPSI CD2-5/300     to redo
             
             
Detailed log by Andrew Cardwell at this link:

https://drive.google.com/file/d/1W8WmNyP4JGHWUndK6K35aClI1ztZUik_/view?usp=sharing

INAF queue observing, 2022 July 11 - July 12

Observer: A. Cardwell
Telescope Operator: Josh Williams
Astronomers from Italy: Ester Marini and Felice Cusano
Instrument: PEPSI

Summary

Due to the Covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (S.Paiano, A. Rossi, Felice Cusano and E. Marini) connected from Italy.

At sunset the sky is cloudy and we cannot open.

Night duration (12 degree - twilight) 03:35 - 11:15 UT = 7 h 50 m
Observing time: 0h 0min (%)*
Weather time loss: 0h 0min (%)*
Technical time loss: 0h 0min (%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
             
             
             
             

Detailed log by Andrew Cardwell at this link:

Topic revision: r1 - 22 Aug 2022, FeliceCusano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback