INAF queue observing, 2022 January 13 - January 14

Observer: Ilya Ilyn, O. Kuhn
Telescope Operator: D. Garcia-Huerta
Astronomers from Italy: Felice Cusano
Instrument: PEPSI

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F. Cusano, A. Rossi, S. Paiano and E. Marini) connected from Italy.

Nights with variable clouds and moon at 88%. Firt part of the night we did observation with PEPSI-POL.
Problem in pointing DG Tau, too close to the moon, it was not possible to observe.
Starting from 10:40 high wind prevents observations in the north-west and west direction. At 11:50 we closed for high wind.

Night duration (12 degree - twilight) 01:15 - 13:20 UT = 12 h 05m
Observing time: 09h 58min (82.5%)*
Weather time loss: 1h 07min (9.2%)*
Technical time loss: 1h 00min (8.3%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Gangi RY Tau PEPSI-POL CD3,CD5-6 2.8h    
Gangi RW Aur PEPSI-POL CD4, CD5-6 2.8h    
Ripepi ASASJ064152-0120.1 PEPSI-PFU CD3-5 0.5h   S/N ~100 blue side
Ripepi 2MASSJ05580941+2802335 PEPSI-PFU CD3-5 0.85h   S/N ~127 blue side
Clementini Gaia980773034927503104 PEPSI-PFU CD2-4 0.55h/1.1h   stopped in the middle of exp for high wind, S/N~48 & 90
Bellazzini G5759671677898613632 PEPSI-PFU CD3-6 0.44h   S/N ~64 & 102
Bellazzini G3696558646635083776 PEPSI-PFU CD3-6 0.44h   S/N ~62 & 96
Bellazzini G3616328554466296960 PEPSI-PFU CD3-6 0.44h   wind reaches 20km/h in the middle of the exp (9mins left), S/N ~ 156 & 255
Bellazzini G1226104831048552448 PEPSI-PFU CD3-6 0.33h   S/N ~ 116 & 163
Bellazzini G1235761287623879296 PEPSI-PFU CD3-6 0.23h   sky brightness 16th in the middle of exp (5mins left), we stopped the exp at 7mins (sky is ~4150 cnts and the target 4350). This object should be re-observed.
Deatailed log by Olga Kuhn at this link:

https://drive.google.com/file/d/1qCYbVRITY03OzdIDf3JVRb0nZfsW3enV/view?usp=sharing

INAF queue observing, 2022 January 30 - January 31

Observer: Dave Thompson
Telescope Operator: Steve Allanson
Astronomers from Italy: Simona Paiano, Ester Marini (Felice Cusano and Andrea Rossi)
Instrument: MODS

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F. Cusano, A. Rossi, S. Paiano and E. Marini) connected from Italy.

We plan to perform MODS observations during all night (in case of clouds or high seeing we plan to switch to PEPSI).

Mostly clear night, but high humidity at the sunset that prevents the observations.
The observations started from 07:00UT

Night duration (12 degree - twilight) 01:45UT - 13:20 UT = 12 h 05m
Observing time: 6h 38min (54.9%)*
Weather time loss: 5h 27min (45.1%)*
Technical time loss: 0h 00min (0%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Paiano 4FGLJ0631.0+5626 MODS1+2 MODS1-2 dualgrating 1.5/1.5h mods1[b0076-0078/r0083-0084]-mods2[b0075-0077/r0081-0083] Seeing ~ 1.4-1"
Std GD153 MODS1+2 MODS1-2 dualgrating   mods1[b0079-0081/r0088-0090]-mods2[b0078-0081/r0086-0088] for Paiano
Marchesi J1030 MODS1+2 MOS dualgrating ID540449 - mods.28.LBTz3v2.mms 4.3/4h mods1[b0082-0088/r0094-0101]-mods2[b0081-0087/r0092-0098] Seeing ~0.8-1.5" (1.5" during the beginning of the 3rd exp, we took a 7th exp of 1200s)
Paiano 4FGLJ1119.9-1007 MODS1+2 MODS1-2 dualgrating 1.5/1.5h mods1[b0089-0091/r0104-0106]-mods2[b0088-0091/r0102-0105] Variable seeing, object very low: we took another exposure of 230s but only on MODS2 because MODS1 was behind
Paiano 4FGLJ1441.4-1934 MODS1+2 MODS1-2 dualgrating 1.0/1.0h mods1[b0092-0094/r0110-0112]-mods2[b0092-0094/r0109-0111] Midpoint of the second exposure was around 12deg twilight

Additional comments:

Detailed log by Dave Thompson at this link:

https://docs.google.com/document/d/104Fc_YeG0ojnp1EZTmj3kRbJ1oSCq-OjrLEE9Lse4S4/edit?usp=sharing

INAF queue observing, 2022 January 31 - February 1

Observer: Dave Thompson
Telescope Operator: Steve Allanson
Astronomers from Italy: Felice Cusano, Simona Paiano, Ester Marini
Instrument: MODS

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F. Cusano, A. Rossi, S. Paiano and E. Marini) connected from Italy.

We plan to perform PEPSI observations during all night because the sky is cloudy.
A power glitch in the afternoon is preventing the opening of the dome. At the sunset all the instruments and the telescopere are shut down.
The problem can not be solved before tomorrow, the telescope stay closed all the night.

Night duration (12 degree - twilight) 01:45UT - 13:20 UT = 12 h 05m
Observing time: 0h 0min (%)
Weather time loss: 0h 0min (%)
Technical time loss: 12h 05min (100%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
           

Additional comments:

Detailed log by Dave Thompson at this link:

Topic revision: r1 - 01 Feb 2022, FeliceCusano