INAF queue observing, 2021 December 20 - December 21

Observer: O. Kuhn
Telescope Operator: S. Allanson
Astronomers from Italy: Andrea Rossi, Felice Cusano, Simona Paiano and E. Marini
Instrument: MODS

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F. Cusano, A. Rossi, S. Paiano and E. Marini) connected from Italy.

We can not use LUCI1 for all the observing run due to a problem with the rotator. LUCI1-AO observations are not possible.
At the sunset the sky is clear, starting observations at twilight. Increasing clouds during the night, stop observations for couds at 4:35.
Opening again at 06:11, then variable clouds all the night.

Night duration (12 degree - twilight) 01:15 - 13:20 UT = 12 h 05m
Observing time: 8h 9min (67.5%)*
Weather time loss: 3h 56min (32.5%)*
Technical time loss: h min (%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calib arc+flats MODS1+2 dualgrat     BIAZZO masks
Calib arcs MODS1+2 dualgrat      
Calib slitless MODS1+2 dualgrat     slitless flats
Calib sliflats MODS1+2 dualgrat     5",0.6".0.8"
STD Feige110 MODS1+2 dualgrating      
Mannucci J034319 MODS1+2 dualgrating slit 0.6"     4 times, we did not have the time to take 5th due to weather time loss
Mannucci J012534 MODS1+2 dualgrating slit 0.6"     4 times
Biazzo ssh-284 F08 MODS1+2 MOS dual ID582936 b 1.3h/1.3h ; r 1.7h/1.7h mods1-2b.0020-0022,0027; mods1r.0058-0061,0067; mods2r.0057-0060,0066 Seeing ~0.8-1". See additional comment below **
Biazzo ssh-284 F08 MODS1+2 MOS dual g,r 0.07h/0.07h mods1-2b.0023-0026; mods1r.0062-0065, mods2r.0061-0064 Seeing ~ 1"
Biazzo ssh-284 F05 MODS1+2 MOS dual ID594959 1.3h/1.3h mods1-2b.0028-0031; mods1r.0071-0074; mods2r.0070-0073 Seeing ~ 0.6-0.8"; we have ~ 2 mag of extinction (mostly on 1st exp) and clouds, we decided to take a 4th exp of 600s
Biazzo ssh-284 F05 MODS1+2 MOS dual g,r 0.07h/0.07h mods1-2b.0032-0035; mods1r.0075-0078, mods2r.0074-0077 Seeing ~ 0.8-0.9"

Additional comments:

** We decided to took a 4th exposure of 600s due to clouds and scattered moonlight, but we accidentally took the 4th spec exposure on the red side only. We resend the acq script and we proceeded to take a single set of exposures, blue & red.

Detailed log by Olga Kuhn at this link: https://drive.google.com/file/d/14nrLFCgCyieBLBClGP-bMuW-_3hncHbH/view?usp=sharing

Detailed log for MODS calibration by Olga Kuhn at this link: https://drive.google.com/file/d/1SoyZ2vLLTniPEJlS9BwD9A6k8mb8S_PB/view?usp=sharing

INAF queue observing, 2021 December 21 - December 22

Observer: O. Kuhn
Telescope Operator: D. Gonzalez-Huerta
Astronomers from Italy: Andrea Rossi, Felice Cusano, E. Marini and Simona Paiano
Instrument: PEPSI

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F. Cusano, A. Rossi, S. Paiano and E. Marini) connected from Italy.

At the sunset the sky is completely covered by clouds, we stay closed.
At ~8:00 the sky starts to clear out, we open and keep observing with PEPSI for the rest of the night.

Night duration (12 degree - twilight) 01:15 - 13:20 UT = 12 h 05m
Observing time: 4h 55min (40%)*
Weather time loss: 7h 06min (57%)*
Technical time loss: 0h 22min (3%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Bellazzini Gaia DR2 834056058741414400 PEPSI1-2 D300/CD3-6     S/N-red~130,-blue~70
Bellazzini Gaia DR2 3846427888295815552 PEPSI1-2 D300/CD3-6     S/N-red~220,-blue~ 190. increased te exp to 10 mins because of the clouds
Bellazzini Gaia DR2 781931511002696448 PEPSI1-2 D300/CD3-6     S/N-red~360,-blue~240, 10mins exp (clouds)
Bellazzini Gaia DR2 3857833427353671808 PEPSI1-2 D300/CD3-6     S/N-red~190,-blue~110
Bellazzini Gaia DR2 4032595650923124864 PEPSI1-2 D300/CD3-6     S/N-red~170,-blue~100
Bellazzini Gaia DR2 770396873818723456 PEPSI1-2 D300/CD3-6     S/N-red~200,-blue~125
Bellazzini Gaia DR2 3917538905901096192 PEPSI1-2 D300/CD3-6     S/N-red~220,-blue~140
Bellazzini Gaia DR2 4007474181050310016 PEPSI1-2 D300/CD3-6     S/N-red~160,-blue~80
Bellazzini Gaia DR2 3946087931475890560 PEPSI1-2 D300/CD3-6     S/N-red~290,-blue~190
Bellazzini Gaia DR2 1456142282990484608 PEPSI1-2 D300/CD3-6     S/N-red~210,-blue~130
Bellazzini Gaia DR2 4003355955952701696 PEPSI1-2 D300/CD3-6     S/N-red~110,-blue~60
Bellazzini Gaia DR2 3960271214861103616 PEPSI1-2 D300/CD3-6     S/N-red~110,-blue~70, the star was off fiber on sx side for a while, but the spectrum does not look bad
Bellazzini Gaia DR2 3735399547720979456 PEPSI1-2 D300/CD3-6     S/N-red~150,-blue~80
Bellazzini Gaia DR2 1461607268096999680 PEPSI1-2 D300/CD3-6     S/N-red~180,-blue~130, 15mins exposure
Bellazzini Gaia DR2 1538656541845737856 PEPSI1-2 D300/CD3-6     S/N-red~180,-blue~110 , 20mins of exp. Star was off fiber again on the sx side, but S/N is good
Bellazzini Gaia DR2 3643857920443831168 PEPSI1-2 D300/CD3-6     S/N-red~180,-blue~130, 15mins of exp
Bellazzini Gaia DR2 1475828798168058624 PEPSI1-2 D300/CD3-6     S/N-red~142,-blue~90, 15mins of exp, exposure stopped at 1.5min left because the star jumped off the fiber
Detailed log by Olga Kuhn at this link: https://drive.google.com/file/d/1sPptz_1OpgDc3ScaRpo3MuhRBcfdTqc5/view?usp=sharing

INAF queue observing, 2021 December 22 - December 23

Observer: O. Kuhn
Telescope Operator: D. Gonzalez-Huerta
Astronomers from Italy: Simona Paiano, E. Marini, Andrea Rossi and Felice Cusano
Instrument: PEPSI

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F. Cusano, A. Rossi, S. Paiano and E. Marini) connected from Italy.

At the sunset the sky is very cloudy, but fast variable.
At 00:44 we are opening and keep observing with PEPSI for the rest of the night.

Night duration (12 degree - twilight) 01:15 - 13:20 UT = 12 h 05m
Night duration for INAF (12 degree - handover) 01:15 - 07:12 UT = 05 h 57m
Observing time: 2 h 2 min (34.2%)*
Weather time loss: 3 h 55 min (65.8%)*
Technical time loss: h min (%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Rainer HAT-P-65 PEPSI1-2 D300/CD1-4     S/N-red~130,-blue~30, high sky background
Rainer HAT-P-65 PEPSI1-2 D300/CD2-5     S/N-red~154,-blue~53
Rainer HAT-P-65 PEPSI1-2 D300/CD3-6     S/N-red~140,-blue~80
Clementini Gaia DR2 1982512068675148032 PEPSI1-2 D300/CD2-4     S/N-red~90,-blue~
Clementini TYC 3970-844-1 PEPSI1-2 D300/CD2-4     S/N-red~68,-blue~ , difficulty in pointing, much cloud

Detailed log by Olga Kuhn at this link:

https://drive.google.com/file/d/1XRdlON1UyiNbjSGSuqjrTb7LISEZoSMl/view?usp=sharing