INAF queue observing, 2021 October 10 - October 11

Observer: A. Cardwell
Telescope Operator: J. Williams
Astronomers from Italy: Andrea Rossi , Felice Cusano
Instrument: LBC

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F. Cusano, A. Rossi, S. Paiano and E. Marini) connected from Italy.

At the sunset the sky is clear.

Night duration (12 degree - twilight) 01:45 - 12:30 UT = 10 h 45m
Observing time: 0 h 0 min ( 89%)*
Weather time loss: h min (0%)*
Technical time loss: 1h 10min (11%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Giunta AO_L LBCs g+i 0.18h+0.18h   twice DIMM 1"
Giunta AO_K LBCs g+i 0.18h+0.18h   twice
Giunta KN_G LBCs g+i 0.18h+0.18h   twice
Giunta KN_H LBCs g+i 0.18h+0.18h   twice; note the astigmatism
Belladitta J0309 LBCs r, i+z 3+3h/4+4h   lbcr.20211011.055623.fits not good, 3xr+i, 3xr+z
Giunta AO_M LBCs g+i 0.09h+0.09h    
Giunta AO_N LBCs g+i 0.09h+0.09h    
Giunta KN_E LBCs g+i 0.09h+0.09h    
Giunta KN_F LBCs g+i 0.09h+0.09h    
Giunta twilight_fields LBC r+r 0.1+0.1h   4 fields for 3 times
             
             
Detailed log by A. Cardwell at this link:

https://drive.google.com/file/d/1kZEN-8Ra1kRyqG5HphBlGTwDFtavGrd8/view?usp=sharing

INAF queue observing, 2021 October 11 - October 12

Observer: A. Cardwell
Telescope Operator: J. Williams
Astronomers from Italy: Simona Paiano, Andrea Rossi
Instrument: PEPSI, LUCI

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F. Cusano, A. Rossi, S. Paiano and E. Marini) connected from Italy.

At the sunset the sky seems clear, but the wind is over shutdown limit. For this reason, we remain closed. High wind also at the 12 deg twilight.

Night duration (12 degree - twilight) 01:45 - 12:30 UT = 10 h 45m
Observing time: 0h 0 min ( 0%)*
Weather time loss: 10h 45 min (100%)*
Technical time loss: 0h 0 min (0%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
CALIB Dark-bino LUCI1-2     luci[1,2].20211012.0001-0020 Giannini_12
CALIB Dark-bino LUCI1-2     luci[1,2].20211012.0021-0025 Rossi_18
CALIB Dark-mono LUCI1     luci1.0026-0400 LaBarbera _17
CALIB Dark-mono LUCI1 18NDIT+24NDITx2p51   luci1.0026-0400 probably not necessary Izzo_20
CALIB Dark-bino LUCI1-2 18NDIT+24NDITx2p51   luci1.0051-0060, luci2.0026-0035. Izzo_20
CALIB Dark-mono LUCI1 24x2p51   luci1.0061-0065 probably not necessary Izzo_20
CALIB flats and arcs LUCI1-2 zJ_G200   luci1.0089-0106, luci2.0059-0076 Giannini
CALIB flats LUCI1-2 ima J,H,K   luci1.0107-0136, luci2.0077-0106 Giannini
CALIB flats and arcs LUCI1-2 G210 H,0.5"   luci1.0137-0154 La Barbera
CALIB flats LUCI1-2 ima J   luci1.0155-0164, luci2.0107-0116 Rossi
CALIB flats LUCI1-2 ima J+H   luci1.0170-0184, luci2.0122-0136 Izzo
CALIB Bias MODS1-2     mods[1,2][b,r].20211012.0003-0022 bias for all
CALIB arcs MODS1-2 dualgrating   mods[1,2]r.0023-0025, mods[1,2]b.0023-0025 Paiano , Mannucci, Giannini, Severgnini
CALIB slitflat MODS1-2 dualgrating 0.6"   mods[1,2]r.0026-0031, mods[1,2]b.0026-0031 Mannucci
CALIB slitflat MODS1-2 dualgrating 0.8"   mods[1,2]r.0032-0037, mods[1,2]b.0032-0037 Giannini, Severgnini
CALIB slitflat MODS1-2 dualgrating 1.2"   mods[1,2]r.0044-0049, mods[1,2]b.0044-0049 Paiano
CALIB slitflat MODS1-2 dualgrating 5"   mods[1,2]r.0056-0058, mods[1,2]b.0056-0061 STD
CALIB slitless MODS1-2 dualgrating   mods[1,2]r.0059-0063, mods[1,2]b.0062-0071 Paiano , Mannucci, Giannini, Severgnini
CALIB flat MODS1-2 dual ima r,i   mods[1,2]r.0064-0073  
CALIB arcs+flat MODS1-2 MOS ID 560500   mods[1,2]r.0079-0087 Saracco
CALIB arcs+flat MODS1-2 MOS ID 565554   mods[1,2]r.0088-0096 Saracco
CALIB slitflat MODS1-2 redgrating 5"   mods[1,2]r.0097-00100 Saracco
CALIB slitless MODS1-2 redgrating   mods1r.0105-00109, mods2r.0103-00107 Saracco
CALIB flat MODS1-2 red ima r,i   mods[1,2]r.0108-0119 Paiano
CALIB arcs+flat MODS1-2 mos_503108   mods[1 2]b.0082-090, Mods[1 2]r.0120-0128 Biazzo
CALIB arcs+flat MODS1-2 mos_503312   mods[1 2]b.0091-099, mods[1 2]r.0129-0137 Biazzo
             
Detailed log by A. Cardwell at this link:

https://drive.google.com/file/d/1wjXF3hWUYiyhaFf_gqIMo2ECkWNBLltX/view?usp=sharing

INAF queue observing, 2021 October 12 - October 13

Observer: A. Cardwell
Telescope Operator: J. Williams
Astronomers from Italy: Simona Paiano, Felice Cusano
Instrument: PEPSI, LBC

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F. Cusano, A. Rossi, S. Paiano and E. Marini) connected from Italy.

At the sunset the sky seems clear, but humidity is 99.9%, temperature is -6 C, and wind is still high. There is ice on the building from last night, so we cannot open.

Night duration (12 degree - twilight) 01:45 - 12:30 UT = 10 h 45m
Observing time: 0 h min ( 0%)*
Weather time loss: 10 h 45min (100%)*
Technical time loss: h min (%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
CALIB arcs+flat MODS1-2 mos_572754   Mods[1,2]b.0003-0011, Mods[1,2]r.0003-0011 Biazzo
CALIB arcs+flat MODS1-2 mos_582936   Mods[1,2]b.0012-0020, Mods[1,2]r.0012-0020 Biazzo
CALIB arcs+flat MODS1-2 mos_5925566   Mods[1,2]b.0021-0029, Mods[1,2]r.0021-0029 Biazzo
CALIB arcs+flat MODS1-2 mos_5924958   Mods[1,2]b.0030-0038, Mods[1,2]r.0030-0038 Biazzo
CALIB arcs+flat MODS1-2 dual_slitlessflat   Mods[1,2]b.0039-004? , Mods[1,2]r.0039-004? Biazzo
             
             
Detailed log by A. Cardwell at this link:

https://drive.google.com/file/d/1nX6_lx_t8fu5bb3NpBFdACjqoxrPkILz/view?usp=sharing

INAF queue observing, 2021 October 13 - October 14

Observer: D. Thompson
Telescope Operator: S. Allanson
Astronomers from Italy: Simona Paiano, Felice Cusano
Instrument: PEPSI, LBC

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F. Cusano, A. Rossi, S. Paiano and E. Marini) connected from Italy.

At the sunset the sky is clear and conditions are good. We open. MODS1 is unavailable for all the night for a technical failure We close at 1:58UT for high particle counts detected (smoke).

Night duration (12 degree - twilight) 01:45 - 12:30 UT = 10 h 45m
Observing time: 9 h 45 min ( %)*
Weather time loss: 1 h min (%)*
Technical time loss: h min (%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Ripepi UCAC4 592-100381 PEPSI1-2 D300/CD3-5     21 minutes, S/N(red)~197
Ripepi NSVS 8394284 PEPSI1-2 D300/CD3-5     S/N(red)~190
Ripepi Gaia2246124001521354368 PEPSI1-2 D300/CD3-5     S/N(red)~190
Clementini TYC 3970-844-1 PEPSI1-2 D300/CD2-4     S/N(red)~150
Clementini Gaia1982512068675148032 PEPSI1-2 D300/CD2-4     S/N(red)~160
Ripepi ASASSN-V J021635.96+651035.5 PEPSI1-2 D300/CD3-5     S/N(red)~220
Rainer HAT-P-19 PEPSI1-2 D300/CD1-4     S/N(red)~180
Rainer HAT-P-19 PEPSI1-2 D300/CD2-5     S/N(red)~220
Rainer HAT-P-19 PEPSI1-2 D300/CD3-6     S/N(red)~290
Rainer HAT-P-28 PEPSI1-2 D300/CD1-4     S/N(red)~250(?)
Rainer HAT-P-28 PEPSI1-2 D300/CD2-5     S/N(red)~113
Rainer HAT-P-28 PEPSI1-2 D300/CD3-6     S/N(red)~150
Giunta AO_L LBCs g+i 0.18h+0.18h   seeing : B=1.27” fwhm, R=0.99”
Giunta AO_K LBCs g+i 0.18h+0.18h   seeing : B=1.25” fwhm, R=0.99”
Giunta KN_G LBCs g+i 0.18h+0.18h   seeing : B=1.06” fwhm, R=0.83”
Giunta KN_H LBCs g+i 0.18h+0.18h   seeing : B ~ 1.0” fwhm, R=?”
Belladitta J0309 LBCs r+i,     seeing : B=1.10” fwhm, R=1.06”
Belladitta J0309 LBCs r+z     seeing : B=1.08” fwhm, R~0.99” , from lbc.2021014.094405/lbc.20211014.094401 seeing increased up to 1.4" , lbc.095535 seeing~1.2" (seeing unstable during the second part of the observation)
Giunta KN_E LBCs g+i 0.09h+0.09h   seeing : B=1.5” fwhm, R=1.3”
Giunta KN_F LBCs g+i 0.09h+0.09h   seeing : B=1.7” fwhm, R=1.7”
Giunta AO_M LBCs g+i 0.09h+0.09h   seeing : B~2.0” fwhm, R=1,7”
Giunta AO_N LBCs g+i 0.09h+0.09h   seeing : B=1.7” fwhm, R=1.7”
Giunta twilight_fields LBC r+r 0.1+0.1h   F1, F2, F3, F4, F5
             
             
Detailed log by D. Thompson at this link: https://drive.google.com/file/d/1VDOPmL3cmsL1-bAR2POHGJC9Hxd_sbhL/view?usp=sharing

INAF queue observing, 2021 October 14 - October 15

Observer: D. Thompson
Telescope Operator: S. Allanson
Astronomers from Italy: Andrea Rossi, Felice Cusano
Instrument: PEPSI, LUCI

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F. Cusano, A. Rossi, S. Paiano and E. Marini) connected from Italy.

At the sunset the sky is clear and conditions are good, we open the dome.

Night duration (12 degree - twilight) 01:45 - 12:30 UT = 10 h 45m
Observing time: 10h 30min (98%)*
Weather time loss: 0h 0min (0%)*
Technical time loss: 0h 15min (2%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Ripepi Gaia2246124001521354368 PEPSI1-2 D300/CD3-5     S/N(red)~270
Ripepi NSVS 8394284 PEPSI1-2 D300/CD3-5     S/N(red)~250
Ripepi UCAC4 592-100381 PEPSI1-2 D300/CD3-5     S/N(red)~220
Clementini TYC 3970-844-1 PEPSI1-2 D300/CD2-4     S/N(red)~170
Clementini Gaia1982512068675148032 PEPSI1-2 D300/CD2-4     S/N(red)~164
Ripepi ASASSN-V J021635.96+651035.5 PEPSI1-2 D300/CD3-5     S/N(red)~200
Rainer Kepler-1517 PEPSI1-2 D300/CD1-4     S/N(red)~167
Rainer Kepler-1517 PEPSI1-2 D300/CD2-5     S/N(red)~209
Rainer Kepler-1517 PEPSI1-2 D300/CD3-6     S/N(red)~193
Rainer Kepler-5 PEPSI1-2 D300/CD1-4     S/N(red)~114
Rainer Kepler-5 PEPSI1-2 D300/CD2-5     S/N(red)~138
Rainer Kepler-5 PEPSI1-2 D300/CD3-6     S/N(red)~150
Rainer Kepler-5 PEPSI1-2 D300/CD3-6     S/N(red)~150
Ripepi UCAC4 660-036351 PEPSI1-2 D300/CD3-5     S/N(red)~243
La Barbera Feige110 LUCI1 G210 H 0.5"   luci1.20211015.0005-0008  
Telluric HIP 1383 LUCI1 G210 H 0.5"   luci1.20211015.0012-0017  
La Barbera HD 27524 LUCI1 G210 H 0.5"   luci1.20211015.0022-0029  
Telluric HD 22859 LUCI1+2 G200 zJ+HK   luci1.0033-40,luci2.0005-0012 for Giannini
Giannini Gaia21bkw LUCI1+2 G200 zJ+HK 0.5+0.5h luci1.0045-0052,luci2.0018-0024 DIMM variable ~1.2-2",clear
Giannini Gaia21bkw LUCI1+2 JHK ima 0.1h luci1.0053-0067,luci2.0025-0039 DIMM ~1.5"
Giannini Gaia21arv LUCI1+2 JHK ima 0.1h luci1.0068-0082,luci2.0040-0054 DIMM ~1"
Giannini Gaia18cjb LUCI1+2 JHK ima 0.1h luci1.0083-0097,luci2.0055-0069 DIMM ~1"
Giannini Gaia18cjb LUCI1+2 G200 zj+HK 0.5+0.5h luci1.0092-0109,luci2.0074-0081 DIMM ~1.1"
Telluric HD 38088 LUCI1+2 G200 zJ+HK   luci1.0113-0120,luci2.0085-0092 for Giannini
Giannini Gaia21arv LUCI1+2 G200 zj+HK 0.5+0.5h luci1.0125-0132,luci2.0097-0104 DIMM 1-1.5"
Telluric HD 52461 LUCI1+2 G200 zJ+HK   luci1.0136-0143,luci2.0108-0115 for Giannini
Giannini Gaia19fct LUCI1+2 G200 zj+HK 0.5+0.5h luci1.0149-0156,luci2.0120-0127 DIMM ~1"
Giannini Gaia19fct LUCI1+2 K ima --   saturates in K; we stop
Detailed log by D. Thompson at this link:

https://docs.google.com/document/d/1ZxKT-XbuHjj831U3HA7wEEQUgSaE7hl5hI2PTa1uIhc/edit?usp=sharing

INAF queue observing, 2021 October 15 - October 16

Observer: D. Thompson
Telescope Operator: S. Allanson
Astronomers from Italy: Andrea Rossi, Simona Paiano
Instrument: LUCI, MODS

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F. Cusano, A. Rossi, S. Paiano and E. Marini) connected from Italy.

At the sunset the sky is clear and conditions are good, we open the dome.

Night duration (12 degree - twilight) 01:45 - 12:30 UT = 10 h 45m
Observing time: 10h 15min (95%)*
Weather time loss: h 6 min (1%)*
Technical time loss: h 24 min (4%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Izzo SN2021ymj LUCI1+2 J H ima 0.05+0.1h luci1.20211016.0001-0014,luci2.20211016.0001-0014 DIMM~1"
Giannini gaia20cwd LUCI1+2 J+H+Ks ima 0.1+0.1+0.1h luci1.0015-0029,luci2.0015-0029 DIMM1.5"
Giannini gaia20cwd LUCI1+2 zJ+HK G200 0.75" 0.5+0.5h luci1.0034-0041,luci2.0034-0041 DIMM1.5-2"
Telluric HD189411 LUCI1+2 zJ+HK G200 0.75"   luci1.0045-0052,luci2.0045-0052 for Giannini
Giannini gaia18dvy LUCI1+2 zJ+HK G200 0.75" 0.5+0.5h luci1.0057-0064,luci2.0057-0064 DIMM1.5-2"
Giannini gaia18dvy LUCI1+2 J+H+Ks ima 0.1+0.1+0.1h luci1.0065-0079,luci2.0065-0079 DIMM ~2-3"
Izzo SN2021zfw LUCI1+2 J H ima 0.05+0.1h luci1.0080-0097,luci2.0080-0097 1.5-2"
Giannini gaia21bkw LUCI1+2 J+H+Ks ima 0.1+0.1+0.1h luci1.0098-0112,luci2.0098-0112 DIMM ~2-3"
Giannini gaia21bkw LUCI1+2 zJ+HK G200 0.75" 0.5+0.5h luci1.0117-00124,luci2.0117-0124 DIMM ~ 5" (GS~2.5")
Telluric HD22859 LUCI1+2 zJ+HK G200 0.75"   luci1.0128-0135,luci2.0128-0135 for Giannini
Telluric BD+493793 LUCI1+2 zJ+HK G200 0.75"   luci1.0139-0146,luci2.0139-0146 for Giannini
Giannini Gaia19bpg LUCI1+2 zJ+HK G200 0.75" 0.19+0.42h luci1.0152-0163,luci2.0152-0163 Saturated emission line in the spectrum. We adjusted the script but this does not help. See log for details. DIMM ~ 2.5-3"
Paiano 4FGLJ0055.7+4507 MODS1+2 dual grating 1.3+1.3h mods1/2b.0002-009 ; mods1/2r.0005-0012 started with seeing=1.7 and improved during the observation down to 1.2". Taken two exposures of 10mins more
Standard G191-B2 MODS1+2 dual grating   mods1/2b.0010-0012 ; mods1/2r.0015-0017 for Paiano
Paiano 4FGLJ0302.5+3354 MODS1+2 dual grating 0.75+0.75h mods1/2b.0013-0015 ; mods1/2r.0021-0023 Seeing ~ 0.8-1" (GS)
Rossi GRB210919A MODS1+2 dual grating 0.5+0.5h mods1/2b.0016-0017 ; mods1/2r.0027-0028 Seeing ~ 0.9" (GS)
Standard GD71 MODS1+2 dual grating 0.15+0.15h mods1/2b.0018-0020 ; mods1/2r.0031-0033 for Rossi
Detailed log by D. Thompson at this link: https://drive.google.com/file/d/1wzM3aE1deAiVf6hzWnQMR0EIfoRYLO3j/view?usp=sharing

Topic revision: r6 - 18 Oct 2021, FeliceCusano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback