INAF queue observing, 2021 September 16 - September 17

Observer: A. Cardwell
Telescope Operator: J. Williams
Astronomers from Italy: Felice Cusano, Andrea Rossi
Instrument: MODS/LBC

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F. Cusano, A. Rossi, S. Paiano and E. Marini) connected from Italy.

At the sunset the sky is clear.

Night duration (12 degree - twilight) 02:30 - 12:10 UT = 9 h 40m
Observing time: 8h 40min ( 90%)
Weather time loss: * 0h 20min (3%)*
technical time loss: * 0h 40min (7%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calibration arc MODS1+2 dual grating   mods1/2.b/r.20210917.0003-0005  
Calibration slit flat MODS1+2 dual grating   mods1/2.b/r.20210917.0006-0011 slit 1.2"
Calibration bino bias LBC      
Standard BD+33-2642 MODS1+2 dual grating   mods1/2b.0012-0015 ; mods1/2r.0015-0018  
Paiano 4FGLJ2207 MODS1+2 dual grating 1.25/1.25h mods1/2b.0016-0019 ; mods1/2r.0022-0025  
Paiano 4FGLJ2331 MODS1+2 dual grating 1.5/1.5h mods1/2b.0020-0022 ; mods1/2r.0029-0031  
Paiano 4FGLJ2317 MODS1+2 dual grating 1.25/1.25h mods1/2b.0023-025 ; mods1/2r.0035-0037  
Standard Feige110 MODS1+2 dual grating   mods1/2b.0026-0028 ; mods1/2r.0040-0042  
Paiano 4FGLJ0026 MODS1+2 dual grating 1.25/1.25h mods1/2b.0029-0031 ; mods1/2r.0046-0048 check: high background? low blazar state?
Standard Feige110 MODS1+2 red grating   mods1/2r.0051-0053 for Saracco. Saracco aborted problems w faint guide-star
Paiano 4FGLJ0006 MODS1+2 dual grating 2.0/1.5h mods1/2b.0032-0035 ; mods1/2r.0057-0060 take 1 exp more because of clouds
Calibration slit flat MODS1+2 dual grating   mods1/2b.0029-0031 ; mods1/2r.0046-0048 slit 5"
Giunta KN+AO fields LBCblue+LBCred g+i 0.36+0.36h   clear, seeing ~0.8"
Rossi GRB 210905A LBCblue+LBCred r+z 0.16h+0.16h    
Giunta 2021PB2 LBCred i+z 0.08h   LBC blue camera not available
Calibration skyflats LBCred i-sloan, z-sloan     0+180deg
Detailed log by A. Cardwell at this link:

https://drive.google.com/file/d/1eNQDiFc_04tEwFcyOB5FsZFDtc2Vj0cN/view?usp=sharing

INAF queue observing, 2021 September 17 - September 18

Observer: A. Cardwell
Telescope Operator: J. Williams
Astronomers from Italy: Felice Cusano, Simona Paiano
Instrument: PEPSI

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F. Cusano, A. Rossi, S. Paiano and E. Marini) connected from Italy.

At the sunset the sky is cloudy, we stay closed. Conditions are better we open the dome at 4 UT, we start with PEPSI.
4:30 we keep observing between clouds.

Night duration (12 degree - twilight) 02:30 - 12:10 UT = 9 h 40m
Observing time: 7 h 18 min ( 77%)*
Weather time loss: 2 h 13 min (23%)*
Technical time loss: 0 h 9 min (0%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calibration   MODS1+2        
Bellazzini_6 Gaia DR2 175494277028410368 PEPSI D300/CD3/CD6     stopped for clouds after two minutes
Clementini_23 TYC 3970-844-1 PEPSI D300/CD2/CD4     clouds
Clementini_23 Gaia DR2 1982512068675148032 PEPSI D300/CD2/CD4     lost guide star, repeated two times. Seeing is excellent ~0.6”.
Bellazzini_6 Gaia DR2 2831099131350883840 PEPSI D300/CD3/CD3     seeing very good ~0.5"
Bellazzini_6 Gaia DR2 2638388587343373568 PEPSI D300/CD3/CD6      
Bellazzini_6 Gaia DR2 2770652380103869568 PEPSI D300/CD3/CD6      
Bellazzini_6 Gaia DR2 2642675235286941952 PEPSI D300/CD3/CD6     seeing ~0.6", some clouds, stopped after t~4mins
Ripepi_24 ASASSN-VJ021635.96+651035.5 PEPSI D300/CD3/CD5      
Bellazzini_6 Gaia DR2 18865184286788352 PEPSI D300/CD3/CD6     sky is mostly clear
Bellazzini_6 Gaia DR2 5169232769846881920 PEPSI D300/CD3/CD6      
Bellazzini_6 Gaia DR2 3268830653286376704 PEPSI D300/CD3/CD6      
Bellazzini_6 Gaia DR2 3192796881606263424 PEPSI D300/CD3/CD6      
Ripepi_24 NSVS4269811 PEPSI D300/CD3/CD5      
Ripepi_24 UCAC4_660-036351 PEPSI D300/CD3/CD5      
Ripepi_24 2MASS J05580941+2802335 PEPSI D300/CD3/CD5     sky is mostly clear, seeing=0.89"-0.67"
Ripepi_24 UCAC4 593-018905 PEPSI D300/CD3/CD5     sky very good, seeing~0.6"
Clementini_23 Gaia DR2 980773034927503104 PEPSI D300/CD2/CD4     clear sky, seeing=0.7" (stable)
Detailed log by A. Cardwell at this link: https://drive.google.com/file/d/1GjdDKfHWoUCEg5ZsSo53ttTrbGl7WIW-/view?usp=sharing

INAF queue observing, 2021 September 18 - September 19

Observer: A. Cardwell
Telescope Operator: J. Williams
Astronomers from Italy: Andrea Rossi, Simona Paiano
Instrument: PEPSI

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F. Cusano, A. Rossi, S. Paiano and E. Marini) connected from Italy.

At the sunset the sky is cloudy Weather is with clouds and thunders, plus high humidity. We open at 4:15 UT

Night duration (12 degree - twilight) 02:30 - 12:10 UT = 9 h 40m
Observing time: 2 h 35 min ( 27%)*
Weather time loss: 6 h 30 min (67%)*
Technical time loss: 0 h 35 min (6%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
CALIB BIAS MODS1+2 dual   mods1b.0004-0022,mods1r.0004-0022 -- mods2b.0004-0022, mods2r.0004-0022  
Rainer_25 Kepler-5 PEPSI1+2 D300/CD1/CD4      
Rainer_25 Kepler-5 PEPSI1+2 D300/CD2/CD5      
Rainer_25 Kepler-5 PEPSI1+2 D300/CD3/CD6     seeing=1.65"-1.3" - humidity~88% - SNR~76-120
Clementini_ 23 TYC 3970-844-1 PEPSI1+2 D300/CD2/CD4     seeing~1" - humidity=93% - SNR~148-218
Clementini_ 23 Gaia DR2 1982512068675148032 PEPSI1+2 D300/CD2/CD4     seeing~0.9" (improving during the obs) - humidity=94.7% - SNR~137-225
Bellazzini_6 Gaia DR2 2659693686716034176 PEPSI1+2 D300/CD3/CD6     seeing~0.8" - humidity= 94.4% (increasing)- SNR~112-156 , stopped after 18mins of the 25mins
CALIB-Piconcelli_11 DARK LUCI1     luci1.20210919.0001-0010  
CALIB-Rossi_18 DARK LUCI1     luci1.20210919.0011-0025  
CALIB-Giannini_12 DARK LUCI1     luci1.20210919.0026-0045  
CALIB-LaBarbera_17 DARK LUCI1     luci1.20210919.0046-0053  
Starting a full bias sequence on MODS. mods[1|2][b|r].20210919.0004-0022.

Detailed log by A. Cardwell at this link:

https://drive.google.com/file/d/1xYQvZNABZ-fKAio3EfsGTdtl_3TXw9sg/view?usp=sharing

INAF queue observing, 2021 September 19 - September 20

Observer: A. Cardwell
Telescope Operator: J. Williams
Astronomers from Italy: Simona Paiano , Felice Cusano
Instrument: PEPSI

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F. Cusano, A. Rossi, S. Paiano and E. Marini) connected from Italy. At the sunset the sky is cloudy and with fog. The humidity is high (~99%) and with a increasing trend, we cannot open.
We open at 5:20 humidity at 85%.

Night duration (12 degree - twilight) 02:30 - 12:10 UT = 9 h 40m
Observing time: 8 h 50 min ( 71%)*
Weather time loss: 2 h 50 min (29%)*
Technical time loss: h min ()*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
CALIB-Izzo_20 DARK LUCI1 dark_18NDIT+24NDITx2p51   luci1.20210920.0002-0011  
CALIB BIAS MODS1+2 dual   mods1b.0003-0022,mods1r.0003-0022 -- mods2b.0003-0022, mods2r.0003-0022  
CALIB BIAS LBC        
CALIB-Izzo_20 DARK LUCI1 dark_24x2p51   luci1.20210920.0012-0016  
CALIB cals for 1x1 binning MODS1+2 dual grating   mods1b.0023-00,mods1r.0023-00 -- mods2b.0023-00, mods2r.0023-00  
CALIB-Piconcelli_11 ARC-FLAT LUCI1 zJ200_lambda1p17   luci1.20210920.0017-0034  
CALIB-LaBarbera_17 ARC-FLAT LUCI1 G210_H_slit0p5   luci1.20210920.0035-0052  
CALIB-Giannini_12 ARC-FLAT LUCI1 zJ_G200   luci1.20210953.0035-0070  
CALIB-Giannini_12 ARC-FLAT LUCI1 HK_G200   luci1.20210953.0071-0088  
CALIB-Giannini_12 FLAT0ima LUCI1 J   20210953.0089-0098  
CALIB-Giannini_12 FLAT0ima LUCI1 H   20210953.0099-0108  
CALIB-Giannini_12 FLAT0ima LUCI1 Ks   20210953.0109-0118  
Bellazzini_6 G4296558843393685632 PEPSI1+2 D300/CD3/CD6     seeing~1.5" - humidity=83% - SNR~106-188
Bellazzini_6 G4299974407538484096 PEPSI1+2 D300/CD3/CD6     seeing~1.4" - humidity=82% - SNR~145-220
Clementini_ 23 G1982512068675148032 PEPSI1+2 D300/CD2/CD4      
Clementini_ 23 TYC-3970-844-1 PEPSI1+2 D300/CD2/CD4      
Bellazzini_6 G1749568744937863168 PEPSI1+2 D300/CD3/CD6      
Bellazzini_6 G2659693686716034176 PEPSI1+2 D300/CD3/CD6     seeing~1.7"
Bellazzini_6 G36036820017906336 PEPSI1+2 D300/CD3/CD6     seeing~2.1"
Bellazzini_6 G2448812029433640704 PEPSI1+2 D300/CD3/CD6     seeing~2"
Bellazzini_6 G385118623534199808 PEPSI1+2 D300/CD3/CD6     seeing~1"
Bellazzini_6 G314799593600582656 PEPSI1+2 D300/CD3/CD6     seeing~1"
Bellazzini_6 G306253094013406464 PEPSI1+2 D300/CD3/CD6     seeing~1"
Bellazzini_6 G296549899602832768 PEPSI1+2 D300/CD3/CD6     seeing~1"
Bellazzini_6 G488257280987718912 PEPSI1+2 D300/CD3/CD6     seeing~1"
Bellazzini_6 G2503491051919554304 PEPSI1+2 D300/CD3/CD6     seeing~1"
Ripepi_24 NSVS4269811 PEPSI1+2 D300/CD3/CD5      
Ripepi_24 UCAC 593-018905 PEPSI1+2 D300/CD3/CD5      
Ripepi_24 2massJ05580941+2802335 PEPSI1+2 D300/CD3/CD5      
Clementini_ 23 G980773034927503104 PEPSI1+2 D300/CD2/CD4      
Detailed log by A. Cardwell at this link:

https://drive.google.com/file/d/1-BTzWoogmnM5i4uRr2EEYvyyrfE00VoF/view?usp=sharing

INAF queue observing, 2021 September 20 - September 21

Observer: A. Cardwell
Telescope Operator: J. Williams
Astronomers from Italy: Simona Paiano , Felice Cusano
Instrument: PEPSI, LUCI

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F. Cusano, A. Rossi, S. Paiano and E. Marini) connected from Italy.

At the sunset the sky is clear, with humidity~50%

Night duration (12 degree - twilight) 02:30 - 12:10 UT = 9 h 40m
Observing time: 9 h 40 min ( 97%%)*
Weather time loss: 0 h min (%)*
Technical time loss: h 20 min (3%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Bellazzini_6 G1625310187102498048 PEPSI1+2 D300/CD3/CD6     seeing~"0.8, S/N~130 CD6
Bellazzini_6 G1298276602498467072 PEPSI1+2 D300/CD3/CD6     seeing~"0.7 S/N~130 CD6
Bellazzini_6 G4569481097095820032 PEPSI1+2 D300/CD3/CD6     seeing~"0.7 S/N~128
Bellazzini_6 G4500186227885057024 PEPSI1+2 D300/CD3/CD6     seeing~"0.7
Bellazzini_6 G4479226310758314496 PEPSI1+2 D300/CD3/CD6     seeing~"0.9 S/N~117
Bellazzini_6 G1762525321240783232 PEPSI1+2 D300/CD3/CD6     seeing~"0.8
Clementini_ 23 TYC 3970-844-1 PEPSI1+2 D300/CD2/CD4     S/N~230
Clementini_ 23 G1982512068675148032 PEPSI1+2 D300/CD2/CD4      
Crestani_DDT HD331986 PEPSI1+2 D300/CD123/CD46     seeing ~0.7-0.9", average S/N~70 CD1, S/N~200 CD4, S/N~100 CD2, S/N~150 CD3, S/N~230 CD6
Ripepi_24 ASASSN-VJ021635.96+651035.5 PEPSI1+2 D300/CD3/CD5     seeing ~1.1", S/N~90-190
LaBarbera Telluric - HIP 1383 LUCI1 1.65/G210-H   luci1.0010-0013 seeing~0.8"
LaBarbera M31_1 + sky LUCI1 1.65/G210-H   luci1.0018-0043 seeing~ 0.8"- 0.9" -
LaBarbera M31_2 + sky LUCI1 1.65/G210-H   luci1.0044-0069 seeing~ 1.1" - 1.0" - 0.9"
LaBarbera M31_3 + sky LUCI1 1.65/G210-H   luci1.0070-0087 seeing~ 1.0" - 1.3"
LaBarbera Telluric - HIP 1383 LUCI1 1.65/G210-H   luci1.0091-0094 seeing~0.95"
LaBarbera Std star - HD27254 LUCI1 1.65/G210-H   luci1.0098-00  
Detailed log by A. Cardwell at this link:

https://drive.google.com/file/d/1XSBNWbtDlh2ssOEVtiFsSa_pcw0Mt8J8/view?usp=sharing

INAF queue observing, 2021 September 21 - September 22

Observer: A. Cardwell
Telescope Operator: J. Williams
Astronomers from Italy: Andrea Rossi , Felice Cusano
Instrument: LUCI1

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F. Cusano, A. Rossi, S. Paiano and E. Marini) connected from Italy.

At the sunset the sky is clear

Night duration (12 degree - twilight) 02:30 - 12:10 UT = 9 h 40m
Observing time: 9 h 40 min ( %)*
Weather time loss: 0 h min (%)*
Technical time loss: 0 h min ()*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
telluric HIP87027 LUCI1 G200zJ,1.17,slit1"   luci1.0018-0021  
Piconcelli J170100 LUCI1 G200zJ,1.17,slit1" 0.5/0.5 hr luci1.0026-0033 DIMM<1",clear completed
Giannini Gaia17bpi LUCI1 ima, JHK 0.1/0.1h luci1.0034-0048; 0080-0094 DIMM<1", clear completed
telluric HD177085 LUCI1 G200zJ +HK,1.17+1.95,sli0.75"   luci1.0052-0059  
Giannini Gaia17bpi LUCI1 G200zJ +HK,1.17+1.95,sli0.75" 0.5/0.5hr luci1.0064-0079 DIMM<1",clear completed
Giannini Gaia20eae LUCI1 ima, JHK 0.1/0.1h luci1.0095-0124 DIMM~1.2", clear completed
telluric HD189411 LUCI1 G200zJ +HK,1.17+1.95,sli0.75"   luci1.0128-0135  
Giannini Gaia20eae LUCI1 G200zJ +HK,1.17+1.95,sli0.75" 0.5/0.4h luci1.0141-156 DIMM 1.3",clear completed
telluric HD13100 LUCI1 G200zJ +HK,1.17+1.95,sli0.75"   luci1.0160-0167  
Giannini Gaia18eap LUCI1 ima, JHK 0.1/0.1h luci1.0168-0197 DIMM~1.0-1.6", clear completed
Giannini Gaia18eap LUCI1 G200zJ +HK,1.17+1.95,sli0.75" 0.7/0.5hr luci1.0203-0221 DIMM 1.3",clear completed, last 10 minutes seeing ~2.5", taking 0.19h more in HK
Izzo SN2021vju LUCI1 ima, J-H   luci1.0222-026 dimm ~1.1-2.1"
telluric HIP13917 LUCI1 G200zJ   luci1.0253-256 for Piconcelli
Piconcelli J0209 LUCI1 G200zJ 0.75/0.5h luci1.0263-0274 dimm~1.2", from 10:23 seeing blow up to 3", after ~12 minutes down to 1.2", we do 4exp more
Rossi GRB200826A LUCI1 ima J 0.5/1h luci1.0 fwhm~1.1" on images, after 11:45 seeing jumped to 1.5-2, target to be repeated
Izzo SN2021yal LUCI1 ima, J-H      
Detailed log by A. Cardwell at this link:

https://drive.google.com/file/d/1QhbjRHihEj0SFH83072WF4LYMrKDkW_V/view?usp=sharing

Other note

INAF queue observing, 2021 September 22 - September 23

Observer: A. Cardwell
Telescope Operator: S. Allanson
Astronomers from Italy: Andrea Rossi , Simona Paiano
Instrument: MODS

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F. Cusano, A. Rossi, S. Paiano and E. Marini) connected from Italy.

At the sunset the sky is partially cloudy with more clouds coming from the south.

Night duration (12 degree - twilight) 02:30 - 12:10 UT = 9 h 40m
Observing time: 0 h min ( 0%)*
Weather time loss: 9 h 40 min (%)*
Technical time loss: 0 h min (0%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calib DARK LUCI1     luci1.202109XX.00XX-00XX Test from the Bologna control room
Calib_Saracco_24 BIAS (8kx3k) MODS1+2 dual   mods1b.00XX-00XX,mods1r.00XX-00XX -- mods2b.00XX-00XX, mods2r.00XX-00XX Test from the Bologna control room
Calibration bino bias LBC     Test from the Bologna control room
Calib flat, arc LUCI1 G200 zJspec     Rossi_18
             
Detailed log by A. Cardwell at this link:

https://drive.google.com/file/d/1wt69ouMhRvPkWtlWf7d3KfBPv6LmyXi2/view?usp=sharing

Other note

During the night the cloudiness was increasing and at 05.30UT the sky was completely covered.

At 06:40UT sky still completely covered by clouds.
Topic revision: r7 - 29 Sep 2021, FeliceCusano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback