-- FeliceCusano - 31 Jan 2021

INAF queue observing, 2021 Jan 16 - Jan 17

Observer: A. Cardwell
Telescope Operator: David Gonzalez HuertaDavid G. H.
Astronomers from Italy: A. Rossi, F. Cusano
Instrument: LUCI-BINO

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (A. Rossi and F. Cusano) connected from Italy.

At the sunset the sky is clear. Wind slightly below the limit. We start with LUCI, opening up at sunset.
The night is characterized by variable bad seeing from 1 to 3"

Night duration (12 degree el twilight) 01:30 - 13:30 UT = 12 h 00m
Observing time: 9h min ( 75%)
Weather time loss: 0h min (0%)
technical time loss 3h 00min ( 25%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Di Criscienzo AND LUCI-BINO K J imaging 0.6h+0.13h   seeing ~1.5" passing cirrus
Rossi_18 GRB 201216C LUCI-BINO H imaging 1h   DIMM ~1.5"
Antoniucci Gaia18cjb LUCI-BINO J imaging 0.01h   completed
Telluric   LUCI-BINO zJ,HK 200, 0.75"slit     the first HK are saturated we change exptime to 2.51
Antoniucci Gaia18cjb LUCI-BINO zJ,HK 200, 0.75"slit 1h zJ + 0.46h HK   completed
Palazzi AT2021any LUCI-BINO J-H imaging 0.25h+0.25h    
Telluric HIP 55627 LUCI-BINO        
Saxena COSMOS1 LUCI-BINO MOS 1h+1h   alignement ?
Di Criscienzo SEXB LUCI-BINO imaging      
Telluric HIP 55627 LUCI-BINO zJspec,1"slit      
Nardini SDSSJ1148 LUCI-BINO zJspec,1"slit 0.26hx2   completed
Nardini SDSSJ1159 LUCI-BINO zJspec,1"slit 0.33hx2   completed
Telluric HIP 61138 LUCI-BINO zJspec,1"slit      
-- AndreaRossi - 17 Jan 2021

Detailed log of the nigh by A. Cardwell at this link:

https://drive.google.com/file/d/1vgBWXVIhg9tSa-pMcgLNEOIHLPQ5axd9/view?usp=sharing

INAF queue observing, 2021 Jan 17 - Jan 18

Observer: A. Cardwell , Ilya Ilyin
Telescope Operator: David Gonzalez HuertaDavid G. H.
Astronomers from Italy: A. Rossi
Instrument: PEPSI

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (A. Rossi and F. Cusano) connected from Italy.

The night is shared with AZ, we take the first half
At the sunset the sky is clear. Wind slightly below the limit. We start with PEPSI, opening up at sunset.

Night duration (12 degree el twilight) 01:20 - 07:20 UT = 6 h 00m
Observing time: 5h 50min (97%)
Weather time loss: 0h 0min (%)
technical time loss 0h 10min (3%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Clementini ID 198xxx PEPSI   15m  
Silvotti PG2349+002 PEPSI   1h 10m  
Clementini ID 198xxx PEPSI   15m  
Clementini ID 302xxx PEPSI   20m  
Clementini ID 110xxx PEPSI   20m  
Lanzafame Proteus PEPSI   1h20m   the first isolated 10 min can be added, they are good
Clementini ID 302xxx PEPSI   20m  
Clementini ID 110xxx PEPSI   20m  
Clementini ID 302xxx PEPSI   20m  
-- AndreaRossi - 18 Jan 2021 Detailed log by A. Cardwell at this link: