INAF queue observing, 2020 Oct 12 - Oct 13

Observer: A. Cardwell
Telescope Operator: S. Allanson
Astronomers from Italy: F. Cusano, S. Paiano
Instrument: LUCI-BINO

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F.Cusano, S. Paiano) connected from Italy.

At the sunset the sky is clear.

Night duration (12 degree el twilight) 1:50 - 12:30 UT = 10 h 40m

Observing time: * 9 h 20 min (87%)*

Weather time loss: * 0 h 0 min (0 %)*

technical time loss * 1 h 20 min (13%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Polletta dark LUCI 1        
Gargiulo dark LUCI 1, 2        
Cassara dark LUCI 1, 2        
Polletta PLCK_G67.1+22.5 LUCI 1 z - ESM 0 hrs   attempted, but not performed for the ESM-AO issue
Tell_Cassara HIP106817 LUCI 1, 2 G200-zJ - MOS     Telluric VIPE4
Cassara VIPE4 LUCI 1, 2 G200-zJ - MOS 2 hrs   seeing = 0.9" - 0.75" - 1.0" , completed
Tell_Feruglio HIP 115428 LUCI 1, 2 G210-H - LS     Telluric - C1 , seeing = 0.9"
Feruglio S82X _2058 - C1 LUCI 1, 2 G210-H - LS 1 hrs   seeing = 0.9" - 0.8" , completed
Gargiulo UDS-3441 - VAN001 LUCI 1, 2 G200-zJspec - MOS 1.5 hrs   seeing ~ 1"-0.9" , completed
Tell_Gargiulo HIP10185 LUCI 1, 2 G200-zJspec - MOS     Telluric VAN001
Tell_Gargiulo HIP10185 LUCI 1, 2 G200-zJspec - MOS     Telluric VAN003
Gargiulo UDS_3448 - VAN003 LUCI 1, 2 G200-zJspec - MOS 4.5 hrs   seeing ~ 0.5"-0.7" , completed
Paiano TXS0506+056 LUCI 1, 2 J 2,5 h   preferred ESM, but not available. We did SL. seeing ~ 0.7"
Cassara flats-arcs LUCI1,2 G200-zJ - MO     for VIPE4
Paiano flats LUCI 1,2 J     for TXS
Gargiulo flat arcs LUCI 1,2 G200-zJspec - MOS     for VAN001
Gargiulo flat arcs LUCI 1,2 G200-zJspec - MOS     for VAN003
Feruglio flat arcs LUCI1,2 G210-H - LS     for S82X _2058

Details

detailed log by A. Cardwell at this link: https://drive.google.com/file/d/1_GoCCj5PoClDf6kxG6v0NUOyXmVO81UC/view?usp=sharing

INAF queue observing, 2020 Oct 13 - Oct 14

Observer: A. Cardwell
Telescope Operator: Josh
Astronomers from Italy: F. Cusano, S. Paiano, A. Rossi
Instrument: LUCI-BINO

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F.Cusano, S. Paiano) connected from Italy.

At the sunset the sky is clear.

Night duration (12 degree el twilight) 1:50 - 12:30 UT = 10 h 40m

Observing time: 10 h 19 min (96.7%)

Weather time loss: * 0 h 0 min ( 0 %)*

technical time loss * 0h 21 min (3.3 %)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Cassara' dark LUCI 1-2        
Paiano dark LUCI 1-2        
Feruglio dark LUCI 1 -2        
Polletta PLCK_G67.1+22.5 LUCI 1 z - ESM 1.5 hrs   seeing = 0.6" - 0.85" - 1.3" - 0.85" good images from 64
Tell_Feruglio HIP 115428 LUCI 1 G210-H - ESM     Telluric - A6
Feruglio S82X _1940 - A6 LUCI 1 G210-H - ESM 0.7 hrs luci1.0103-113 seeing=0.65", PA angle not correct and possible tilt. Probably the target was not in the slit.
Tell_Cassarà HIP13917 LUCI 1,2 zJ200   luci1.0119-0122, luci2.0030-003  
Cassarà VIPE1 LUCI 1,2 zJ200 0.8+0.8hrs luci1.0127-0140, luci2.0038.0051 We cannot see the science spectra or emission lines. Problem with the mask ?
D'Onofrio NGC1042 LBC blue+red g-band, r-band 1.6+1.6 hrs hr seeing ~1.", completed
Rossi_BACKUP GRB161007A LBC blue+red g,r on LBCblue + z LBCred 0.67+0.67 hrs   LBC imaging completed
Schmidt J0823+3427 LBC blue+red r-band, i-band 0.55+0.55 hrs   1 OB done
Calibration Skyflats LBCblue+red r+z     note: there are good flats in both PA maybe just for z-band
Polletta flat LUCI 1 z-band     for PLCK_G67.1+22.5
Cassarà flat,arcs LUCI 1,2 zJ200     for VIPE1

Details

detailed log by A. Cardwell at this link: https://docs.google.com/document/d/1sis_Y_biPPjm7VkoRA9gsvRfmn7sW_U-jIMI_QEYbXQ/edit?usp=sharing

INAF queue observing, 2020 Oct 14 - Oct 15

Observer: A. Cardwell
Telescope Operator: Josh
Astronomers from Italy: F. Cusano, S. Paiano, A. Rossi
Instrument: LUCI-BINO

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (A. Rossi, S. Paiano, F. Cusano) connected from Italy.

At the sunset the sky is clear.

Night duration (12 degree el twilight) 1:50 - 12:30 UT = 10 h 40m

Observing time: * 09 h 50 min (92 %)*

Weather time loss: * 0 h 0 min ( 0 %)*

technical time loss * 0 h 50 min (8 %)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Di Criscienzo dark LUCI 1-2       for And e Peg
Polletta PLCK_G67.1+22.5 LUCI 1 z - ESM 1.2 hrs   seeing = 0.8" - 1.2"
Tell_Feruglio HIP 115428 LUCI 1 G210-H - ESM     Telluric - A6
Feruglio S82X _1940 - A6 LUCI 1 G210-H - ESM 1.3 hrs luci1.0103-113 seeing=1.5" during the first and last exposures, ~1" in between
Tell_Antonucci HIP16652 LUCI 1-2 G200-zJspec     Telluric
Antonucci AGLL129 LUCI 1-2 G200-zJspec 1.0 hrs   seeing = 1.2" -1.1" (DIMM), ~ 0.75” (guiders).
Tell_Antonucci HIP16652 LUCI 1-2 G200-HKspec     Telluric
Antoniucci AGLL129 LUCI 1-2 G200-HKspec 0.8 hrs   seeing = 1.2" -1.1" (DIMM), ~ 0.75” (guiders).
Di Crescienzo AndVII LUCI 1 -2 Ks 0.6hrs   seeing = 1.45"
Di Crescienzo AndVII LUCI 1 -2 J 0.13hrs   seeing = 1.1" - 1.4"
Rossi_BACKUP_2 GRB161007A MODS 1-2 - LS dualgrating, slit 1" 3hrs   seeing ~1"
NOTES:

Feruglio run

We tried to put the target in the slit. According to our check, the target should be inside teh slit. This time the PA was correct. Unfortunately the seeing is very variable, spanning from 1.1" to 2.0" (but the most of time it is ~1.5"). This causes a loss of flux because the used slit is 0.5". In the frames we cannot see the spectrum of the target, also after the sly subtraction.

Around 04.55UT we had an improvment of the seeing and now we can see the spectrum of the target (after the sky subtraction).

At 05:50, suddenly the seeing increased >1.5" and then it started again to decrease slowly.

Details

detailed log by A. Cardwell at this link: https://drive.google.com/file/d/1ppoaVixTCpiBXdE0Pp9Bq8KNCGwWd_9E/view?usp=sharing

INAF queue observing, 2020 Oct 15 - Oct 16

Observer: A. Cardwell
Telescope Operator: Josh
Astronomers from Italy: F. Cusano, S. Paiano, A. Rossi
Instrument: MODS-BINO and LUCI-BINO

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (A.Rossi, S.Paiano and F. Cusano) connected from Italy.

At the sunset the sky is clear.

Night duration (12 degree el twilight) 1:50 - 12:30 UT = 10 h 40m

Observing time: * 9 h 55 min (93 %)*

Weather time loss: * 0 h 0 min ( 0 %)*

technical time loss * 0h 45 min (7 %)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Rossi GRB 200826A MODS 1-2   1.3 hrs   seeing ~ 0.9"
Tell_Feruglio HIP 115428 LUCI 1 G210-H - ESM - slit=0.5"     Telluric - A6
Feruglio S82X _1940 - A6 LUCI 1 G210-H - ESM - slit=0.5" 4hrs   seeing ~0.9"
Tell_Feruglio HIP 17946 LUCI 1 G210-H - ESM - slit=0.5"     Telluric - A6
Tell_Cassarà HIP13917 - VIPF1 LUCI 1,2 zJ200     Telluric = VIPF1
Cassarà VIPF1 LUCI 1,2 zJ200 hrs   seeing = 1.1"
Schmidt J0823+3427 LBC blue+red r-band, i-band hrs   seeing = 1"

Details

Detailed log by A. Cardwell at this link: https://drive.google.com/file/d/1RP33wfOepNZHwXp2-iPEHyAgsmXcuxM-/view?usp=sharing
Topic revision: r3 - 21 Oct 2020, FeliceCusano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback