-- SimonaPaiano - 16 Sep 2020

INAF queue observing, 2020 Sep 06 - Sep 07

Observer: B. Rothberg
Telescope Operator: J. Williams
Astronomers from Italy: F. Cusano, A. Rossi, S. Paiano
Instrument: LUCI-BINO

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F.Cusano, A. Rossi, S. Paiano) connected from Italy.

At the sunset there are some clouds, after twilight the sky cleared out. At 4:35 UT the TO closed the dome for clouds and some lightning he is seeing at distance.
Opening up again at 5:30

Night duration (12 degree el twilight) 2:30 - 12:00 UT = 9 h 30m

Observing time: 6 h 00 min (63%)

Weather time loss: 1 h 50 min (19%)

technical time loss 1 h 40 min (18%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Casasola HIP87643 LUCI 1,2       telluric for Casasola
Casasola Hband LUCI 1,2 G210-H 1h/5h   last 4 exposures in clouds
Rossi GRB200906A LUCI 1,2 H, K 0.5h/1h   backup target, some clouds
Antoniucci V350 Cep LUCI 1,2 G200-zJspec Hkspec     backup target, some clouds
Cassara B4 LUCI 1,2 G200-zJspec 2.22h/2h   completed 4 exps more for variable seeing
Tell_Cassara HIP105693 LUCI 1,2 G200-zJspec     telluric B4
Tell_Gargiulo HIP10185 LUCI 1 G200-zJspec     telluric VAN001
Gargiulo VAN001 LUCI 1 G200-zJspec 1h/10h    

Details

detailed log by B. Rothberg at this link

https://docs.google.com/document/d/1DkSFsJgYllCQgS6-uhc4mXAyflo9kPOlvIduX8c0aAs/edit?usp=sharing

INAF queue observing, 2020 Sep 07 - Sep 08

Observer: B. Rothberg
Telescope Operator: J. Williams
Astronomers from Italy: F. Cusano, A. Rossi, S. Paiano
Instrument: LUCI-BINO

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F.Cusano, A. Rossi, S. Paiano) connected from Italy.

At the sunset the sky is clear.

Night duration (12 degree el twilight) 2:30 - 12:00 UT = 9 h 30m

Observing time: 7 h 48 min (89%)

Weather time loss: 1 h 10 min (7%)

technical time loss 0 h 32 min (3.5 %)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Casasola HIP87643 LUCI 1,2 G210 H and z     telluric for Casasola
Casasola Hband LUCI 1,2 G210-H 1h/5h   completed
Casasola zband LUCI 1,2 G210-z 4h/5h    
Casasola zband LUCI 1,2 z 0.33h/1h   clouds - high exctintion due to the clouds
Antoniucci v1057cyg LUCI 1,2 G200-zJspec 0.10h   backup target, some clouds
Antoniucci AGL129 LUCI 1,2 G200-zJspec 0.0h   backup target, some clouds - done only the Telluric
Antoniucci v350cep LUCI 1,2 G200-zJspec     backup target, some clouds
Antoniucci v350cep LUCI 1,2 HKspec     backup target, some clouds
Tell_Gargiulo HIP10185 LUCI 1,2 G200-zJspec     telluric VAN001
Gargiulo UDS-3441 - VAN001 LUCI 1,2 G200-zJspec 0.40/10h   Seeing=1.2-1.4" and passing clouds
Tell_Antonucci HIP24342 LUCI 1,2 G200-zJspec     telluric V1118Ori
Antoniucci V1118Ori LUCI 1,2 G200-zJspec     backup target, high seeing
Antoniucci V1118Ori LUCI 1,2 HKspec     backup target, high seeing

Details

detailed log by B. Rothberg at this link

https://docs.google.com/document/d/1xAKWetyOqDUXlZbwKl9nCXq9terpEPVj/edit

INAF queue observing, 2020 Sep 08 - Sep 09

Observer: B. Rothberg
Telescope Operator: D. Gonzalez-Huerta
Astronomers from Italy: F. Cusano, A. Rossi, S. Paiano
Instrument: LUCI-BINO

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F.Cusano, A. Rossi, S. Paiano) connected from Italy.

At the sunset the sky is cloudy.

Night duration (12 degree el twilight) 2:30 - 12:00 UT = 9 h 30m

Observing time: 0 h 0 min (0 %)

Weather time loss: 9 h 30 min (100%)

technical time loss 0 h 0 min (0 %)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calibrations Darks LUCI 1,2       for Antoniucci Gargiulo Rossi
Calibrations flat-arcs LUCI 1,2       flat-arcs for Antoniucci Gargiulo

Details

detailed log by B. Rothberg at this link https://drive.google.com/file/d/1xOXoRUCmMAmtDHkMVZH3JsP0lnTToaPi/view?usp=sharing

INAF queue observing, 2020 Sep 09 - Sep 10

Observer: B. Rothberg
Telescope Operator: D. Gonzalez-Huerta
Astronomers from Italy: F. Cusano, A. Rossi, S. Paiano
Instrument: LUCI-BINO

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F.Cusano, A. Rossi, S. Paiano) connected from Italy.

At the sunset the sky is cloudy and windy with guts above the limit of 20 m/s.

Night duration (12 degree el twilight) 2:30 - 12:00 UT = 9 h 30m

Observing time: 0 h 0 min (0 %)

Weather time loss: 9 h 30 min (100%)

technical time loss 0 h 0 min (%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
 

Details

detailed log by B. Rothberg at this link: https://docs.google.com/document/d/1dx53Zarjrwgm1UQIlAO_Y0EUZZ1VhUt6L8DKWNBJmzE/edit?ts=5f59b7ae