INAF queue observing, 2019 July 03 - 04

Observer: A. Rossi, D. Paris
Telescope Operator: J. Williams
Support Astronomer: B. Rothberg (in Tucson)
Instrument: MODS

At the sunset the sky has some passing clouds. We start with MODS.

Summary

Night duration (12 degree el twilight) 3:35 - 11:15 UT = 7 h 40m.

Observing time: h min (80%)

Weather time loss: h min (0%)

technical time loss 1h *30min (20%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calibration arcs+slitflats MODS1+2 dual     for Nacimbeni Ke21
Calibration darks LUCI1 200 MER, normal     for Cassarà e Casasola
Nascimbeni Kelt21 MODS1+2 dual grating 4.8h red, 3.3h blue mods1r.0014-0114, mods1b.0011-0086; mods2r.0020-00116, mods2b.0018-0086 completed: lost start transit; last 1 hour only MODS1, ==to be check
standard Feige110 MODS1+2 dual grating     for Nascimbeni, Antoniucci
Antoniucci V350Cep MODS1+2 dual grating 0.6h/0.5h mods1r.0126-0129,mods1b.0090-93 ; mods2r.0128-0131,mods2b.0090-93 completed, fatto un po di piu'
Calibration slitflats MODS1+2 dual     0.8" for Antoniucci
Calibration slitflats MODS1+2 dual     5" for std feige110
Calibration slitless MODS1+2 dual      
Calibration arcs MODS1+2 dual     Antoniucci
Calibration bias MODS1+2 8k     Antoniucci, Nascimbeni

INAF queue observing, 2019 July 05 - 06

Observer: A. Rossi, D. Paris
Telescope Operator: J. Williams
Support Astronomer: B. Rothberg (in Tucson)
Instrument: MODS

At the sunset the sky is cloudy. DOME closed.

Summary

Night duration (12 degree el twilight) 3:35 - 11:15 UT = 7 h 40m.

Observing time: 00h 30min (7%)

Weather time loss: 7h 10min (93%)

technical time loss h *min (0%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calibration   MODS1+2 dual, red     Palazzi, Moretti
Calibration arcs,flats LUCI1       Moretti, Casasola, Cassarà
Calibration darks LUCI1       Moretti, Casasola, Cassarà
Antoniucci V250Cep MODS1+2 dual ima 6m mods1b.20190706.0023-0025, mods1r.20190706.0035-0037; mods2b.20190706.0023-0025, mods2r.20190706.0035-0037 Antoniucci
Antoniucci V2493Cyg MODS1+2 dual ima 6m mods1b.20190706.0026, mods1r.20190706.0038; mods2b.20190706.0026-0028, mods2r.20190706.0038-0040 Antoniucci MODS1 only first, last MODS2 with cirrus

INAF queue observing, 2019 July 06 - 07

Observer: A. Rossi, D. Paris
Telescope Operator: J. Williams
Support Astronomer: B. Rothberg (on call)
Instrument: MODS

At the sunset the sky is cloudy with occasional showers and storms around the mountain. DOME closed.

Summary

Night duration (12 degree el twilight) 3:35 - 11:15 UT = 7 h 40m.

Observing time: h min (%)

Weather time loss: 7h 40min (100%)

technical time loss h *min (%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
CALIBRATION imaging flats MODS1+2 dual     for e.g. Antoniucci
CALIBRATION slitflats MODS1+2 dual 1.2"      

INAF queue observing, 2019 July 07 - 08

Observer: A. Rossi, D. Paris
Telescope Operator: J. Williams
Support Astronomer: B. Rothberg (on call)
Instrument: MODS

At the sunset the sky is cloudy with occasional showers and storms around the mountain. DOME closed.

Summary

Night duration (12 degree el twilight) 3:35 - 11:15 UT = 7 h 40m.

Observing time: 6h 20min (83%)

Weather time loss: 1h 0min (13%)

technical time loss 0h *20min (4%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
standard BD33 MODS1+2 red grating   mods1r.0004-06; mods2r.0004-06  
standard BD33 MODS1+2 dual grating   mods1b.0002-0004, mods1r.0007-0009; mods2b.0002-0004, mods2r.0007-0009  
Antoniucci V2493Cyg MODS1+2 dual 0.6/0.5 mods1b.0005-0008, mods1r.0013-0016; mods2b.0005-0008, mods2r.0013-0016 completed
standard HIP87643 LUCI1 J 210   luci1.20190708.0012-0015 for Casasola
Casasola   LUCI1 J 210 0.5/5h luci1.20190708.0020-0028 completed J +-1.5" offset to get the 3rd target from bottom
standard HIP106817 LUCI1 zJ 200   luci1.20190708.0032-0035 for Cassarà VIPA4
Cassarà   LUCI1 zJ 200 2/2.0h luci1.20190708.0043-0078 last hour not good, 0.2-1 mag extnction, especially last 20 min

Topic revision: r4 - 08 Jul 2019, AndreaRossi
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback