INAF queue observing, 2019 May 29-30

Observer: F. Cusano
Telescope Operator: S. Allanson
Support Astronomer: O. Kuhn
Instrument:

At the sunset the sky is clear.

Summary

Night duration (12 degree el twilight) 3:23 - 11:11 UT = 7 h 48m

Observing time: 7h 48min (100%)

Weather time loss: 0h min (0%)

technical time loss 0h *min (0%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
calibration flats,arcs,bias MODS1-2 dual grating     Nascimbeni program
Nascimbeni Kelt18 MODS1-2 dual grating 6.6/6.6h   completed
Standard BD+2842 MODS1-2 dual grating      
calibration slitless flat MODS1-2 dual grating      
-- FeliceCusano - 31 May 2019

INAF queue observing, 2019 May 30-31

Observer: F. Cusano
Telescope Operator: S. Allanson
Support Astronomer: O. Kuhn
Instrument: LBC

At the sunset the sky is clear. We start with LBC.
We wanted to change to LUCI around 8:40 UT, but for problem with instrument we stayed with LBC.

Summary

Night duration (12 degree el twilight) 3:23 - 11:11 UT = 7 h 48m

Observing time: 6h 48min (87%)

Weather time loss: 0h min (0%)

technical time loss 1h *min (13%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
calibration bias LBC-B/R       bino bias
calibration sky flat LBC-B/R g; r     good counts
Annibali R26 LBC-B/R g; r 1(bin)/1h(bin)   completed
Annibali R39 LBC-B/R g; r 1.08(bin)/1h(bin)   completed two exps more for elongation
Annibali R44 LBC-B/R g; r 0.37/0.7h(bin)   completed
Prandoni TGSSJ1530 LBC-B/R g; i 0.58/1h g; 0.58/1.5h i   last exp low elevation, but the dimm seeing was 0.5"(!)
Rossi GRB180809B LBC-B/R r; z 0.37/0.37h(bino)   completed
calibration sky flat LBC-B/R r-r; i-z     good counts
-- FeliceCusano - 31 May 2019

INAF queue observing, 2019 May 31- June 01

Observer: F. Cusano
Telescope Operator: S. Allanson
Support Astronomer: O. Kuhn (on call)
Instrument: LBC

At the sunset the sky is clear. We start with LBC. For a moth in LBC-B we switched to LUCI at 5:20. The OSA performed some test on the stability of LUCI

Summary

Night duration (12 degree el twilight) 3:23 - 11:11 UT = 7 h 48m

Observing time: 5h 51min (75%)

Weather time loss: 0h 0min (0%)

technical time loss 1h *57min (25%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
calibration sky flat LBC-B/R g; z     good counts
Annibali R27 LBC-B/R g; r 0.33 in g, 0.66 in r /1h(bino)   red images are good, blue have a spot moving in the fov (maybe a moth?) to be checked
telluric HIP87643 LUCI1-2 G210 J 0.15/0.15h   Casasola
Casasola mask1 LUCI1-2 G210 J 2.22/5h    
Casasola mask1 LUCI1-2 imaging J 0.17/0.5h    
telluric HIP100448 LUCI1-2 G200 zJspec 0.15/0.15h   Cresci
Cresci PSO J308.04 LUCI1-2 G200 zJspec 2.16/2h   completed
Cresci PSO J308.04 LUCI1-2 imag J /0.07h   completed
calibration flat and arc LUCI1-2 G200 zJspec     for Cresci
calibration flat and arc LUCI1-2 G210 J     for Casasola
calibration flat LUCI1-2 imag J      

INAF queue observing, 2019 June 01 - 02

Observer: F. Cusano, A. Rossi
Telescope Operator: S. Allanson
Support Astronomer: O. Kuhn (on call)
Instrument: LBC

At the sunset the sky is clear. We start with LBC.

Summary

Night duration (12 degree el twilight) 3:23 - 11:11 UT = 7 h 48m

Observing time: 7h 28min (%)

Weather time loss: h min (%)

technical time loss h *20min (4%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
calibration dark LUCI       Casasola, Moretti, Cresci
Annibali R25 LBCblue+red g,r 1h/1h   completed
Annibali R27 LBCblue+red g,r 0.33h/1h   repeat last OB seeing too high
Annibali R42 LBCblue+red g,r 0.66/1h   last ob to be repeated for seeing>1.1
Prandoni TGSS1530 LBCblue+red g,i 0.5/1h in g ; 0.5/1.5h in i   g band completed
telluric HIP87643 LUCI1-2 G210 J 0.15/0.15h luci1.20190602.0044-47; luci2.20190602.0044-47 Casasola
Casasola mask1 LUCI1-2 G210 J 0.6/5h luci1.20190602.0052-60; luci2.20190602.0052-60 seeing variable, 1hour done but first 2x4 exposures not good

INAF queue observing, 2019 June 02 - 03

Observer: A. Rossi
Telescope Operator: S. Allanson
Support Astronomer: B. Rothberg (on call)
Instrument: LBC

At the sunset the sky is clear. We start with LBC.

Summary

Night duration (12 degree el twilight) 3:25 - 11:10 UT = 7 h 45m

Observing time: 6*h* 55min (90%)

Weather time loss: 0h 00min (0%)

technical time loss 0h *55min (10%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
calibration dark LUCI2       Bianchi
calibration skyflat LBC V, R      
Annibali R18 LBCb+r g,r 0,66/1h    
Annibali R27 LBCb+r g,r 0,33/1h   completed
Annibali R37 LBCb+r g,r 0,66/1h   completed
Annibali R42 LBCb+r g,r 0,33/1h   completed
Prandoni TGSS1530 LBCblue+red r,i 0.5/1h in r ; 0.5/1.5h in i    
Casasola telluric LUCI1+2 G210 J 0.15/0.15h luci1.20190603.0007-10; luci2.20190603.0017-20  
Casasola mask1 LUCI1+2 G210 J 0.5/5h luci1.20190603.0015-0023 completed
calibration flat LUCI1+2 z,H     Casasola

INAF queue observing, 2019 June 03 - 04

Observer: A. Rossi
Telescope Operator: S. Allanson
Support Astronomer: B. Rothberg (on call)
Instrument: LBC

At the sunset the sky is clear. We start with LBC.

Summary

  • This night is shared with SOUL commissioning

Night duration (12 degree el twilight) 3:25 - 07:08 UT = 3 h 43m.

Observing time: 3h 40min (100%)

Weather time loss: 0h 0min (0%)

technical time loss 0h *0min (0%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
calibration dark LUCI2       Bianchi
calibration skyflat LBC r, r      
Annibali R18 LBCb+r g,r 0.33/1.0h   completed
Annibali R28 LBCb+r g,r 1.0/1.0h   completed
Prandoni TGSS1530 LBCb+r r,i 0.5/1.0h   completed

INAF queue observing, 2019 June 04 - 05

Observer: A. Rossi
Telescope Operator: D. Gonzalez-Huerta
Support Astronomer: B. Rothberg (on call)
Instrument: LBC

At the sunset the sky is cloudy. We start with MODS. We stay closed for clouds

Summary

  • This night is shared with SOUL commissioning

Night duration (12 degree el twilight) 3:25 - 07:07 UT = 3 h 42m.

Observing time: h min (0%)

Weather time loss: 3h 42min (100%)

technical time loss h *min (0%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
calibration slitflat MODS1+2 1as redgrating   ==mods1r.20190605.0002-07 ; mods1r.20190605.0002-07 Moretti
calibration bias MODS1+2 bias3k+8k   mods1r.0008-0017, mods1b.0001-11; mods2r.0008-0017, mods2b.0001-0011 Moretti
calibration slitless flat MODS1+2 redgrating   mods1r.0018-22 ; mods2r.0018-22 Moretti
calibration arcs MODS1+2 redgrating   mods1r.0023-0025;==mods2r.0023-0025== Moretti
calibration slitflat MODS1+2 5as redgrating   mods1r.0026-29, mods1b.0012-14; mods2r.0026-29, mods2b.0012-14 Moretti std
calibration slitflat MODS1+2 0.8as dualgrating   mods1r.0030-34, mods1b.0015-17; mods2r.0030-34, mods2b.0015-17 Antoniucci
calibration slitflat MODS1+2 5as dualgrating   mods1r.0035-37, mods1b.0018-23; mods2r.0035-37, mods2b.0018-23 Antoniucci

INAF queue observing, 2019 June 05 - 06

Observer: A. Rossi
Telescope Operator: D. Gonzalez-Huerta
Support Astronomer: B. Rothberg (on call)
Instrument: LBC

At the sunset the sky is clear. We start with LBC.

Summary

  • This night is shared with SOUL commissioning

Night duration (12 degree el twilight) 3:25 - 07:07 UT = 3 h 42m.

Observing time: 2h 42min (73%)

Weather time loss: h min (0%)

technical time loss 1h *0min (27%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Annibali R31 LBCblue+red g,r 1/1h   completed
Annibali R41 LBCblue+red g,r 0,33/1h    

INAF queue observing, 2019 June 06 - 07

Observer: A. Rossi
Telescope Operator: D. Gonzalez-Huerta
Support Astronomer: B. Rothberg (on call)
Instrument: LBC

At the sunset the sky has some passing cirrus. We start with LBC.

Summary

  • This night is shared with SOUL commissioning

Night duration (12 degree el twilight) 3:29 - 07:07 UT = 3 h 38m.

Observing time: 2h 38min (71%)

Weather time loss: h min (0%)

technical time loss 1h *0min (29%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calibration Bias LBC b+r        
Calibration arcs MODS1+2 dual      
Moretti PS0J14 MODS1+2 red grating 2.4/2.4h   completed
standard BD33 MODS1+2 red grating     for Moretti
Moretti FKJ1312+13 MODS1+2 red grating      
Topic revision: r1 - 07 Jun 2019, FeliceCusano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback