INAF queue observing, 2018 December 09-10

Observer: R. Carini, A. Rossi
Telescope Operator: J. Williams
Support Astronomer: D. Thompson
Instrument: LBC

Summary

Night duration (12\xB0 el twilight) 1:15-13:15 UT = 12h 00m

Observing time: h min (88%) 1.5 hor loss because we could not guide with LBC on Annibali R19, According to Olga email 2019/01/10 was a telescope problem.

Weather time loss: 0h m (0%) technical time loss 1h 30m (12%)

Data Summary

At the sunset the sky is mostly clear, some cirrus on the horizone

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Cusano NW1,2,3 LBC B (blue), V (red) 1.98/3.15   pass some cirrus during the first hour. Done 22...27, but NW3_27 NOT OK: lost guiding
Fabrizio photcal LBC Ug (blue),ri (red) 0.08/0.08 h   completed
Fabrizio TriII _bright LBC Ug (blue),ri (red) 0.06*2/0.06*2 h   completed
Fabrizio TriII LBC U (blue),r (red) 0.42*2/0.42*2 h   completed
DeCarli SDSSJ0842+1218 LBC z (red) 0.7/2h   also got 0.7h in blure r band. Check last 17 images on red, from 08:45 maybe too bad,
Annibali R19 LBC g (blue), r (red)     maybe, the guiding star is not good, maybe , please try again
Annibali R20 LBC g (blue), r (red) 1h/1h   completed

INAF queue observing, 2018 December 11-12

Observer: R. Carini, A. Rossi <br />
Telescope Operator: S. Allenson <br />
Support Astronomer: D. Thompson <br />
Instrument: LBC

Summary

Night duration (12\xB0 el twilight) 1:15-13:15 UT = 12h 00m Observing time: 5h 35min (47%)
Weather time loss: 6h10m(51%)

technical time loss 0h 15m (2%)

Data Summary

At the sunset the sky is cloudy

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
standard star Feige 110 MODS1,2 dual and red grating, red prism      
Antoniucci Ves263 MODS1,2 dual grating 20m mods1r.0015-0018, mods1b.0004-0007; mods2r.0015-0018, mods2b.0004-0007 completed
Moretti A12_new PSO351 MODS1,2 red grating 2.67/2 mods1r.0023-0026; ==mods2r.0022-0025 completed, we have taken one more image due to bad seeing and clouds at the beginning of the esxposure
Moretti A6 PSO315 MODS1,2 red grating 0.67/1.6 mods1r.0030; mods2r.0029  
Antoniucci D75b (ASASSN-V J054621 MODS 1,2 dual grating 0.5/0.5 mods1r.0061-0064, mods1b.0028-0031; mods2r.0065-0068, mods2b.0029-0032 completed
calibrations luci 1,2 dark        
calibration luci 1,2 flat+arc      
calibration mods 1,2 flat, bias, arc        

INAF queue observing, 2018 December 12-13

Observer: R. Carini, A. Rossi <br />
Telescope Operator: S. Allanson <br />
Support Astronomer: D. Thompson <br />
Instrument: LBC

Summary

Night duration (12\xB0 el twilight) 1:15-13:15 UT = 12h 00m Observing time: h min (%)

Weather time loss: 12h m (0%) technical time loss 0h m (0%)

Data Summary

At the sunset the sky is clear but windy. we are closed

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
arc flat MODS Mancini, Gilli, De Carli        
arc flat LUCI CassarĂ¡, Severgnini, Nardini, Rossi, Pinna

INAF queue observing, 2018 December 13-14

Observer: R. Carini, A. Rossi <br />
Telescope Operator: S. Allanson <br />
Support Astronomer: B. Rothberg <br />
Instrument: LBC

Summary

Night duration (12\xB0 el twilight) 1:15-13:15 UT = 12h 00m

Observing time: 11h 40min (97%)
Weather time loss: 0hm(0%)

technical time loss 0h 20m (3%)

Data Summary

At the sunset the sky is clear.
Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Nisini telluric Field 3 LUCI1,2 K   luci1.20181214.0069-0072==; luci2.20181214.0016-0019; luci1.20181214.0073-0076; luci2.20181214.0020-0023 lambda=2.22 micron and lambda=2.20 micron respectively
Moretti A6 PSO315 MODS 1,2 red grating 20m/60m mods1r.20181214.0006*; *mods2r.20181214.0006  
Mancini HATP 48 MODS 1,2 dual grating 6h/5.7h mods1r.0010-0141,mods1b.0002-0118*; *mods2r.0010-0238,mods2b.0002-0138 completed
Gilli mask 44 MODS1,2 dual grating (4+x)h/4h mods1r.0145-0154,mods1b0.0119-0125*; mods2r.0242-0251,mods2b.0139-0145 *completed, images mods1r.0147, mods1b.0121, mods1r.0244, mods2b.0142 are not completed
Gilli mask 31 MODS1,2 dual grating 1.33h/4h mods1r.0158-0159, mods1b-0126-0127*; *mods2r.0255-0256, mods2b.0146-0147  
STD Feige 34 MODS1,2 dual grating     Gilli
CALIBRATION BIAS MODS1,2 2x2 bin     Mancini
Note from Olga: As part of the MODS2R checkout and for a later D night, the standard G191-B2B was observed in red-grating mode. The files are:
  • For 20181204 --- from the SX guide plot, looks like it was clear:
  • mods1r.20181204.0006-08; mods2r.20181204.00-08 G191-B2B red grating STD starting at 2018-12-04T08:00
  • From 20181129 --- the SX guide flux looks pretty stable during the time of this observation:
  • mods1r.20181129.0008-10; mods2r.20181129.0107-109 G191-B2B red grating STD starting at 2018-11-29T08:55

  • The star was observed also in dual grating mode on 20181204 and in dual grating and other modes on 20181129,

INAF queue observing, 2018 December 14-15

Observer: R. Carini, A. Rossi <br />
Telescope Operator: S. Allanson <br />
Support Astronomer: B. Rothberg <br />
Instrument: LBC

Summary

Night duration (12\xB0 el twilight) 1:15-13:15 UT = 12h 00m

Observing time: 8h 0min (67%)

Weather time loss: 4h 00m (33%)

technical time loss 0h 0m (0%)

Data Summary

At the sunset the sky is completely covered.

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
CALIBRATIONS arcflats MODS1,2 mask 31 dual grating     Gilli mask 31
telluric Nisini field 4 HIP16652 luci1,2 MOS G210 HiRes H J K (lambda 2.2) K (2.22)   luci1.0017-0032, luci2.0020-0035  
Nisini Field 4 luci1, 2 MOS G210 HiRes H J K 2h/3h luci1.0040-0055, luci2.0042-0057 we take more images due to clouds, completed
telluric field2 HIP17971 Luci1,2 MOS G210 HiRes H J K (lambda 2.2) K (2.22)   luci1.0059-0074, luci2-0061-0076  
Nisini Field 2 luci1, 2 MOS G210 HiRes K,J 1h/3h luci1.0081-0097, luci2.0085-0100 passing cirrus, to be checked
telluric Marziani HIP52192 luci1, 2       useless
telluric Nardini q6 luci1, 2     luci1.0102-0107 passing cirrus
Nardini q6 luci1 150 K 0.25/0.67 luci1.0113-0116 passing cirrus check please
CALIBRATIONS   Nisini field 4, 2, 3 arcflats