-- RobertaCarini - 11 Nov 2018

INAF queue observing, 2018 November 05-06

Observer: R. Carini, M. Faccini
Telescope Operator: S. Allenson
Support Astronomer: B. Rothberg
Instrument: LUCI1 (LS mode), LUCI2 stops working at 03:14 UT, we can not do MOS programs, MODS1

Summary

Night duration (12\xB0 el twilight) 1:15-12:45 UT = 11h 30m

Observing time: 10h 45min (94%)

Weather time loss: h m (0%)

technical time loss 0h 45m (6%)

Data Summary

At the sunset the sky is clear, wind about 10 m/s, humidity about 43%

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
dark Antoniucci Ves 691 + tell Luci1+luci2     luci1.0001-0015, luci2.0001-0015  
dark Polletta PLCK073 +tell luci1+luci2     luci1.0016-0025, luci2.0016-0025  
dark Nardini q2 J030449 +tell luci1+luci2     luci1.0026-0035, luci2.0026-0035  
Antoniucci telluric (Ves 691) HD 216532 luci1+luci2 ls 0.75, G200LoRes, zjSpec,HKspec   luci1.0039-0046, luci2.0046-0053  
Antoniucci Ves 691 luci11+luci2 ls 0.75, G200LoRes, zjSpec,HKspec 3m +3m luci1.0052-0059, luci2.0059-0066 completed
Antoniucci telluric (IRAS 02276+7225) HD 18326 luci1+luci2 ls 0.75, G200LoRes, zjSpec,HKspec   luci1.0063-0068, luci2.0070-0075  
Antoniucci IRAS 02276+7225 luci1+luci2 ls 0.75, G200LoRes, zjSpec,HKspec 6m +6m luci1.0073-0080, luci2.0080-0087 completed
Antoniucci telluric (V1180 Cas) HIP10024 luci1+luci2 ls 0.75, G200LoRes, zjSpec,HKspec   luci1.0084-0087  
Antoniucci V1180 Cas luci1 ls 0.75, G200LoRes, zjSpec,HKspec 0.7h luci1.0092-0099 completed
Antoniucci Agll354 luci1 ls 0.75, G200LoRes, zjSpec,HKspec 0.5h luci1.0104-111 completed
Antoniucci telluric ( Agll 354, D75b ) HIP 25410 luci1 ls 0.75, G200LoRes, zjSpec,HKspec   luci1.0117-0124  
Antoniucci D75b luci1 ls 0.75, G200LoRes, zjSpec,HKspec 0.7h luci1.0129-0136 completed
Nardini telluric (q5) HIP 13917 luci1 ls 1.0, G150Ks, Ks   luci1.0142-0143  
Nardini q5 SDSS J0303 luci1 ls 1.0, G150Ks, Ks 0.67h luci1.0148-0171 completed
Moretti A14 FKJ0355+00 mods1 red grating 3600 s mods1.0005-0007 completed (we take one more image due to variable seeing)
Antoniucci V900 mon mods1 dual grating 20 m mods1r.0015-0018, mods1b.0002-0005 completed
Antoniucci V899 mon mods1 dual grating 20 m mods1r.0022-0025, mods1b.0006-0009 completed
standard GD 71 mods1 dual grating; red grating   mods1r.0028-0032, mods1b.0010-0012; mods1r.0031-0032  
Calibration Moretti MODS slitflat (1,0", 5.0"), slitless flat, lamp (0.6", 1,0") red grating  
Calibrations Antoniucci MODS slitflat (0.8"), slitless flat, lamp (0.6") dual grating  
Calibration Antoniucci LUCI flat and arc    

INAF queue observing, 2018 November 06-07

Observer: R. Carini, M. Faccini
Telescope Operator: D. Gonzal-Huerta
Support Astronomer: B. Rothberg
Instrument: LUCI1 (LS mode), LUCI2, LUCI1, MODS1

Summary

Night duration (12\xB0 el twilight) 1:15-12:45 UT = 11h 30m

Observing time: 10h 50min (94%)

Weather time loss: h m (0%)

technical time loss 0h 40m (6%)

Data Summary

At the sunset the sky is clear, wind about 10 m/s, humidity about 60%

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
calibration MODS1 standard mods1 dual grating, flat with slit 5.0"   mods1r.20181106.0068-0070-,mods1b.20181106.0037  
Polletta Telluric HIP106817 luci2 G200 Lores, zjspec   luci2.0011-0014 seeing high
Polletta PLCKG073 luci2 G200 Lores, zjspec 1.23 h luci2.0020-0056 seeing variable, sometimes out of spec
Polletta Telluric HIP106817 luci2 G200 Lores, zjspec   luci2.0060-0063 seeing better
Nardini telluric hip 13917 luci1 G150 Ks, Ks   luci1.0005-0008  
Nardini q2 LBQS 03020019 luci1 G150Ks, Ks 0.72 h luci1.0014-0037 completed
Perna Telluric HIP16111 luci2 G200 LoRes, HKspec, zjspect   luci2.0067-0075  
Perna RCSGA327 luci2 G200LoRes; HKspec, zjspec 0.16 h, 1.12 h luci2.0080-0083, luci2.0084-0111 HKspec completed. seeing variable sometimes out of spec
Prandoni USS1 mods1 red grating, slit 2.4" 0.5 h mods1.0010-0012 seeing variable, sometimes out of spec
standard Feige 34 mods1 red grating   mods1r.0016-0019  
Calibration Prandoni   mods1 flat 2.4"   mods1r.0020-0025  
Calibration Perna   luci2 arc+ flat HKspec,zjspec luci2.0117-0127; luci1.0132-0155  
Calibration Polletta   luci2 arc+flat luci2.0147-0155  
Calibration Severgnini luci2 arc+flat luci2.0161-0165  

INAF queue observing, 2018 November 07-08

Observer: R. Carini, M. Faccini
Telescope Operator: D. Gonzal-Huerta
Support Astronomer: B. Rothberg
Instrument: LUCI1 (LS mode), LUCI2

Summary

Night duration (12\xB0 el twilight) 1:15-12:45 UT = 11h 30m

Observing time: 9h 40min (84%)

Weather time loss: h m (0%)

technical time loss 1h 50m (16%)

Data Summary

At the sunset the sky is clear, wind speed about 10 m/s, humidity about 50%

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Dark   luci1 and luci2        
Pinna LO Peg Luci2 AO N30; FeII, P-beta, Ks, H2 30/30 m luci2.0029-0076 completed but some images have the star elongated
Pinna HD16760 LUCI2 AO N30; FeII, P-beta, Ks, H2 30/30 m luci1.0078-0124 seeing variable and high, to be repeated
Perna telluric HIP16111 luci2 mos G200LoRes; zjspec   luci1.0128-0131  
Perna RCSGA327 luci2 mos G200LoRes; zjspec 1.2/3h luci2.0160-00188 the last 4 images have seeing very high, to be repeated
Nisini telluric HIP17971 luci2 mos G210Hires; J,H,K luci2.0194-0205  
Nisini field 3 luci2 mos J,H,K 1.5/3h luci2.0210-0233  
Nardini telluric HIP50459 luci1 ls G150Ks; Ks   luci1.0019-0022  
Nardini q3 SDSS J0945 luci1 ls G150Ks; Ks 0.67/1.33 h luci1.0028-0043 last image in twilight but should be good

INAF queue observing, 2018 November 08-09

Observer: R. Carini, M. Faccini
Telescope Operator: D. Gonzal-Huerta
Support Astronomer: B. Rothberg
Instrument: LUCI1 (LS mode), LUCI2

Summary

Night duration (12\xB0 el twilight) 1:15-12:45 UT = 11h 30m

Observing time: 10h 58min (94%)

Weather time loss: h m (0%)

technical time loss 0h 42m (6%)

Data Summary

At the sunset the sky is clear, wind between 5 - 15 m/s (front - rear) , humidity about 48%

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
calibration LUCI 1 & 2 DARK LUCI     luci1.20181109.0004-0028; luci2.20181109.0006-0030  
Polletta telluric HIP106817 luci2 mos _   luci2.00-00  
Polletta PLCK G73.4-57.5 luci2 mos G200 LoRes, zJspec 0.5/4 h mean seeng 0.6" COMPLETED
Cresci telluric HIP 6159 luci1 ls G200 LoRes, zJspec   luci1.0029-0031  
Cresci A1 QSO J0129 luci1 + luci2 G200 LoRes, zJspec 2h/2h luci1.0037-0044, luci1.0051-0071,luci2.0067-0087 completed
Cresci A1 ima QSO J0129 luci1 + luci2 J 800sec/800sec luci1.0072-0079,luci2.0088-0096 completed
Cresci telluric HIP6159 luci2 ls G200 LoRes, zJspec   luci2.0100-0102  
Pinna V577 Per luci2 AO N30, FeII, Ks, P-beta, H2 0.5/0.5 luci2.0104-0152 completed
Perna RCSGA327 luci2 ls G200 LoRes, zjspec 0.3/3h luci2.0157-0164  
Perna telluric HIP19053 lusi2 ls G200 LoRes, zjspec   luci2.0168-0171  
Severgnini psf UCAC 589-042207 luci2 AO N30, K 180s/180s luci2.0172-0174  
Severgnini A5 sdssj075223 luci2 AO N30, K 0.25/0.5h luci2.0179-0193  
Severgnini psf UCAC 589-042207 luci2 AO N30, K 180s/180s luci2.0194-196  
Nardini telluric HIP50 459 luci1 ls G150Ks, Ks   luci1.0083-0086  
Nardini q3   luci1 ls G150Ks, Ks 0.67/1.33h luci.0091-0105 completed

INAF queue observing, 2018 November 09-10

Observer: R. Carini, M. Faccini
Telescope Operator: D. Gonzal-Huerta
Support Astronomer: O. Kuhn
Instrument: MODS1, LUCI2

Summary

Night duration (12\xB0 el twilight) 1:15-12:45 UT = 11h 30m

Observing time: 8h 0min (70%)

Weather time loss: 3h 0m (26%)

technical time loss 0h 30m (4%)

Data Summary

At the sunset the sky is mostly clear, wind between 5 - 10 m/s (front - rear) , humidity about 60%

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Testa A   MODS 1 ls dual grating 0.97/3 h mods1r.0005-0007,mods1b.0001-0003 the second and third images have seeing out of specific
Antoniucci V733 Cep mods1 ls dual grating 0.5/0.5 mods1r.0011-0014, mods1b.0004-0007 completed
standard BD+28 mods1 ls red and dual grating   mods1r.0020-0022,mods1b.0008-0010  
Fabrizio shall1 Tri II mods1 mos dual grating 0.5/0.5 mods1r.0026,mods1b.0011 completed
Fabrizio shall2 Tri II mods1 mos dual grating 0.5/0.5 mods1r.0030,mods1b.0012 completed
Perna telluric HIP16111 luci2 mos   zjspec luci2.0029-0032  
Perna RCSGA327 luci2 mos zjspec 0.6/3.0 h luci2.0039-0053 completed
Nisini field 3 luci2 ima J, H, Ks 0.1 luci2.0054-0079 completed
Pinna field3 HD16760 luci2 AO Ks luci2.0080-0088  

INAF queue observing, 2018 November 10-11

Observer: R. Carini, M. Faccini
Telescope Operator: D. Gonzal-Huerta
Support Astronomer: O. Kuhn (on call)
Instruments: MODS1, LUCI2

Summary

Night duration (12\xB0 el twilight) 1:15-12:45 UT = 11h 30m

Observing time: 11h 00min (96%)

Weather time loss: h m (%)

technical time loss 0h 30m (4%)

Data Summary

At the sunset the sky is mostly clear, wind between 5 - 10 m/s (front - rear) , humidity about 60%

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
dark Severgnini,Pinna,Nisini, Cresci AO, AO, ima, ima      
Testa A   MODS1 ls dual grating 1h/3h mods1r.20181111.0004-0006, mod1b.20181111.0001-0003 completed
standard standard BD 28 MODS1 dual grating   mods1r.20181111.0009-0011, mod1b.20181111.0004-0006  
Fabrizio Deep2 Tri II MODS1 mos dual grating 2h/4h mods1r.20181111.0016-0019, mod1b.20181111.0007-0010  
standard G191   mods1 dual grating   mods1r.0027-0029,mods1b.0011-0013  
Fabrizio deep2 1h Tri II MODS1 mos dual grating 1h/4h mods1r.0033-0034, mods1b.0014-0016  
telluric Nisini   Luci2 mos G210; J H K   luci2.20181111.0053-0076  
Nisini field 3 Luci2 mos G210; J H K 1.5h/3h luci2.20181111.0053-0076= completed
Nardini q4   luci1 ls G150Ks, Ks 0.45h/0.45h luci.0007-0021 completed, some images have bad seeing
telluric Nardini HIP39540 Luci1 ls G10Ks, Ks   luci1.0025-0028  

INAF queue observing, 2018 November 11-12

Observer: R. Carini, M. Faccini
Telescope Operator: D. Gonzal-Huerta
Support Astronomer: O. Kuhn
Instrument: LUCI1 (LS mode), LUCI2

Summary

Night duration (12\xB0 el twilight) 1:15-12:45 UT = 11h 30m

Observing time: 10h 45min (93%)

Weather time loss: h 45m (7%)

technical time loss 0h m (%)

Data Summary

At the sunset the sky is mostly clear, wind with gusts around 20 m/s, humidity about 20.5%

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calibration Cresci a1, Saracco Luci1==2, luci2      
Mancini Hat-P-47 Mods1 + MOds2 dual grating, blue grating 4.8/5.3 mods1r.0004-0220, mods1b.0001-0143 mods2b.0004-0179 completed, some images are not recovered during the transit.
Moretti A6 Mods1 red grating   mods1r.0025 no good, acquisition wrong
Nisini telluric HIP16652 luci2 mos G210 HiRes, K,J,H   luci2.0032-0043  
Nisini field 4 luci2 mos G210 HiRes, K,J,H 1.18/3h luci2.0048-0068== K, J done, H to be completed, some images have airmass aout of spec  
Antoniucci V900Mon luci2 ls HKspec 8m (120 s each ima) luci2.0074-0077 filter completed
tell Antoniucci HIP33836 luci2 ls HKspec   luci2.0081-0082  
Calibration mods Mancini        
Calibration luci Nisini field4          
Topic revision: r5 - 15 Dec 2018, RobertaCarini
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback