INAF queue observing, 2018 June 24-25

Observer: A. Rossi
Telescope Operator: S. Allanson
Support Astronomer: O. Kuhn (on call)
Instrument: MODS

Summary

This night is shared with LN team. We take second half of the night, starting at ~00:20 local At the sunset the sky is clear
instruments: MODS2 red grating is not working well
Night duration (12° el twilight) 3:35- 11:10 UT = 7 h 35m

Observing time: 7h 25m (98%)

Weather time loss: h m (0%)

technical time loss 10m (2%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
STD BD28 MODS1 red grating     for Caccianiga
Caccianiga GB6J2212 MODS1 red grating 4800/4800s mods1r.20180625.0013-0018 completed
Rossi 49 GRB 180624A MODS1 dual grating 1200/1200 mods1r.20180625.0022-0025, mods1b.20180625.0002-0004 completed, another exposure taken in twilight
STD Feige110 MODS1 dual grating   mods1r.20180625.0029-0031, mods1b.20180625.0005-0007 for Rossi 49 GRB 180624A
Calibrations   MODS1       bias for grating
Calibrations   MODS1       arcs,slitflats,slitless for dual grating
Calibrations   MODS1       arcs red grating

INAF queue observing, 2018 June 25-26

Observer: A. Rossi
Telescope Operator: S. Allanson
Support Astronomer: O. Kuhn (on call)
Instrument: LUCI

Summary

We gave 2 hrs at the beginning of the night to LBTO to solve AGW problems: loosing on large offsets, some software problem At the sunset the sky is clear
instruments: MODS2 red grating is not working well
Night duration (12° el twilight) 3:35- 11:10 UT = 7 h 35m

Important : guiding with LUCI1 needs to abort the pause for collimation when the TiO says collimation is ok.
  • This happens for every active preset, i.e. beginning of a script. You do this on telsvc gui

Observing time: h m (%)

Weather time loss: h m (%)

technical time loss * *(9%) but if we count for 50% LUCI1 images useless, it is another 10%

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
STD BRI2202 LUCI1+2 ima,H2,Ks     per Moscadelli
Moscadelli G01268 LUCI1+2 ima,H2,Ks     we toke more images, because 50% of LUCI1 and 10% on LUCI2 look not well collimated, show elongated or double stars, check but should be completed
Caccianiga GB6J001307 +205335 MODS1 red grating 2400/3600 mods1r.20180626.0005-0008 completed PI confirmed
STD Feige110 MODS1 red grating   mods1r.20180626.0014-0016 per Caccianiga
CALIBRATIONS MODS1 red grating Caccianiga
CALIBRATIONS MODS1 dualgrating imaging flats, maybe useful
CALIBRATIONS Dome Flats LUCI1+2 H2, Ks Per Moscadelli

INAF queue observing, 2018 June 26-27

Observer: A. Rossi
Telescope Operator: G. Bechetti
Support Astronomer: B. Rothberg (on call)
Instrument: MODS1 and LUCI2

Summary

At the sunset the sky is clear
instruments: MODS2 red grating is not working well
Night duration (12° el twilight) 3:35- 11:10 UT = 7 h 35m

Observing time: 7h (94%)

Weather time loss: h m (%)

technical time loss 30*m *(6%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
CALIBRATIONS Darks LUCI1+2 5NDIT*30DIT, int,lir     Per Moscadelli 1268
CALIBRATIONS Darks LUCI1+2 10NDIT*3DIT, int,lir     Per Moscadelli 1268
CALIBRATIONS Darks LUCI2 15rNDIT*6DIT     Per Giannetti AO Agalo22 e 25
CALIBRATIONS Darks LUCI2 10NDIT*5DIT     Per Giannetti AO Agalo22 e 25
STD BD33 MODS1 red grating     Per Piconcelli DDT
Piconcelli DDT J1538 MODS1 red grating 2700/2700s mods1r.20180627.0012-0015 completed
Rossi 49 ATLAS18cow MODS1 dualgrating 600/600s mods1r.20180627.0020-0021, mods1b.20180627.002-003 completed
STD BD33 MODS1 dual grating     per Rossi Atlas18cow
STD   LUCI2 H,Ks imaging     Per Giannetti, twice: beginning and end CHECK ALLIGNEMENT!
Giannetti AGALO22 LUCI2 H,Ks AO imaging 1h/1h completed CHECK ALLIGNEMENT!
Giannetti AGALO25 LUCI2 Ks AO imaging 1h/1h   Ks completed, missing H CHECK ALLIGNEMENT!
Rossi 47 GRB 071021 LUCI2 Ks ESM imaging 30m/1h    
CALIB   MODS1 red grating for Piconcelli DDT sliflats 1"
CALIB SKYFLATS LUCI2 H Ks     For Rossi 47 ESM and Moscadelli
CALIB arcs+slitflats LUCI1+2 H, zJ, 1"slit 1.65 and 1.17     For Rossi 49 GRB130907A

INAF queue observing, 2018 June 27-28

Observer: A. Rossi
Telescope Operator: G. Bechetti
Support Astronomer: B. Rothberg (on call)
Instrument: LUCI1 and LUCI2

Summary

At the sunset the sky is with cirrus
instruments: MODS2 red grating is not working well
Night duration (12° el twilight) 3:35- 11:10 UT = 7 h 35m

Observing time: 5h 30m (73%)

Weather time loss: h 5m (1%)

technical time loss 2h (26%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
CALIB arcs+slitflats LUCI2 HK, zJ, 0.75"slit 1.93 and 1.2     For Rossi 47 ESM
STD HIP87643 luci1.20180628.0004-0011, luci2.20180628.0034-0041 for Antoniucci V371Ser
Antoniucci 8 V371Ser LUCI1+LUCI2 zJ,HK spec 1920/1920s luci1.20180628.0015-0023, luci2.20180628.0045-0053 longslit completed
STD HIP71172 LUCI1+LUCI2 H+zJ   luci1.20180628.0027-0034, luci2.20180628.0057-0064 for Rossi 49
Rossi49 GRB130907A LUCI1+LUCI2 H G210, 1"slit 2h/2h luci1.20180628.0062-0087, luci2.20180628.0092-0117 completed H band
Giannetti AGALO25 LUCI2 H AO imaging 1h/1h   H completed
STD   LUCI2 H imaging     For Giannetti
Rossi 47 GRB 071021 LUCI2 Ks ESM imaging 30m/1h   completed
CALB DOMEFLATS LUCI2 N30 H Ks Per Giannetti

INAF queue observing, 2018 June 28-29

Observer: A. Rossi
Telescope Operator: G. Bechetti
Support Astronomer: D. Thompson (on call)
Instrument: LUCI1 and LUCI2

Summary

At the sunset the sky is half covered with clouds
instruments: MODS2 red grating is not working well
Night duration (12° el twilight) 3:35- 11:10 UT = 7 h 35m

Observing time: h m (%)

Weather time loss: h m (%)

technical time loss h (%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
CALIB DARKS LUCI1+LUCI2 H spectra     For Rossi 49
CALIB DARKS LUCI2 HK,zJ spectra     For Rossi 47
CALIB DARKS LUCI2 imaging     For Rossi 47
CALIB DARKS LUCI2 HK,zJ spectra     For Antoniucci V371Ser and V2492Cyg +telluric
STD HIP 102074   zJ HK   luci1.20180629.0024-0032, luci2.20180629.0042-0048 For Antoniucci V2492Cyg
Antoniucci 8 V2492Cyg LUCI1+LUCI2 zJ HK 1920/1920s luci1.20180629.0037-0044, luci2.20180629.0054-0061 long slit completed
STD   LUCI1+LUCI2     luci1.20180629.0048-0051, luci2.20180629.0065-68 telluric Polletta Phz1119
Polletta Phz1119 LUCI1+LUCI2 HKspec 4800/14400s luci1.20180629.0056-0075, luci2.20180629.0073-0092  
Rossi47 GRB 071021 LUCI2 HKonly 0.5/2h luci2.20180629.0101-0108 to be checked seeing jumping +cirrus
STD HIP111538 LUCI2 HK   luci2.20180629.0112-0115 for ROssi47 GRB071021
CALIB arc flats LUCI1+LUCI2 zJ HKspec     for Antoniucci V2492Cyg and V371Ser
CALIB DOME FLATS LUCI2 N30, H Ks     for Giannetti AO

INAF queue observing, 2018 June 29-30

Observer: F. Cusano, R. Speziali
Telescope Operator: G. Bechetti
Support Astronomer: D. Thompson (on call)
Instrument: LUCI

Summary

At the sunset the sky is covered by clouds and it is raining heavily
At Night duration (12° el twilight) 4:10- 10:35 UT = 6 h 25m

Observing time: 1h 50min (28%)

Weather time loss: 4h 10m (66%)

technical time loss 25*m *(6%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Moscadelli G016.58 LUCI 1+2 Ks, H2 5min, 25 min   luci1 image 007 is not good, problem in collimation
Rossi 47 071021 LUCI 2 esm G200+HKspec, zJspec 28min, 18 min luci2.20180630.0013-0020,21-24  
Telluric HIp111538 LUCI2 G200+HKspec, zJspec   34-36, 37- 41  
Calibration Polletta phz1119 LUCI 1 +2 G200HKspec   luci2.42-62, luci1.9-24  

INAF queue observing, 2018 June 30-July 01

Observer: F. Cusano, R. Speziali
Telescope Operator: G. Bechetti
Support Astronomer: D. Thompson (on call)
Instrument: LUCI

Summary

At the sunset the sky is clear

Night duration (12\xB0 el twilight) 4:10- 10:35 UT = 6 h 25m

Observing time: 5h 05min (74%)

Weather time loss: h m (%)

technical time loss 1h 20m*(26%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calibration phz1119 LUCI 1+2 dark NDIT=1, DIT=120.0 MER, NORM   dark for Polletta phz1119
Calibration telluric LUCI 1+2 dark NDIT=6, DIT=5.0 LIR INT   dark for Polletta telluric
Calibration G016.58 LUCI 1+2 dark NDIT=30, DIT=10.0 LIR INT   dark for Moscadelli H2
Calibration G016.58 LUCI 1+2 dark NDIT=10, DIT=3.0 LIR INT   dark for Moscadelli Ks
Moscadelli G016.58 LUCI 1 H2 1.1h   completed
Standard FS 140 LUCI 1 H2, Ks      
Moscadelli G012.91 LUCI 1 H2, Ks 1.25h, 10min?    
Caccianiga gb6j2357 MODS 1 red grating 1.5h   completed
Standard Feige 110 MODS 1 red grating      

INAF queue observing, 2018 July 01-02

Observer: F. Cusano, R. Speziali
Telescope Operator: G. Bechetti
Support Astronomer: D. Thompson (on call)
Instrument: LUCI

Summary

At the sunset the sky is clear. We stop observtions at 5:20 for clouds.

Night duration (12\xB0 el twilight) 4:10- 10:35 UT = 6 h 25m

Observing time: 3h 10min (49%)

Weather time loss: 3h 15m (51%)

technical time loss *m *(%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Standard hz44 MODS 1 red grating      
Caccianiga gb6j1634 MODS 1 red grating 1h/1.5h mods1r.20180702.0010-0013  
Pancino Pandas 53 MODS 1 dual grating 20 min/20min mods1r.20180702.0022-24, mods1b.20180702.0002-0004 completed
Calibration slit flat 0.6" MODS 1 dual grating   mods1r.20180702.0025-0030, mods1b.20180702.0005-0010  

INAF queue observing, 2018 July 03-04

Observer: F. Cusano
Telescope Operator: D. Gonzal-Huerta
Support Astronomer: B. Rothberg (on call)
Instrument: MODS

Summary

At the sunset there are some clouds and high cirrus, from satellite we see more clouds coming in, we decide to start with MODS

Night duration (12\xB0 el twilight) 4:10- 10:35 UT = 6 h 25m

Observing time: 2h 10min (36%)

Weather time loss: 3h 30m (54%)

technical time loss 40m *(10%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Spiniello KIDS1453 MODS1 dual grating 0.38h/ 0.58h mods1r.20180704.0010-0011, mods1b.20180704.0002-0003 completed
Spiniello KIDS1421 MODS1 dual grating 0.58h/ 0.58h mods1r.20180704.0015-0017, mods1b.20180704.0004-0006 variable seeing 1.5-2.2" and clouds at the end
Antoniucci v2493cyg MODS1 dual grating 20min/20min mods1r.20180704.0021-0024, mods1b.20180704.0007-0010 variable seeing 1.2-1.6" , some clouds, completed
Antoniucci v1057 cyg MODS1 dual grating 15min/20min mods1r.20180704.0028-0030, mods1b.20180704.0011-0013 variable seeing 1.0-1.6" , clouds
Calibration slit flat MODS1 dual grating   slit 0.8"  
Calibration slit flat MODS1 dual grating   slit 1.2"  
Calibration arc MODS1 dual grating   slit 0.6"  

INAF queue observing, 2018 July 04-05

Observer: F. Cusano
Telescope Operator: D. Gonzal-Huerta
Support Astronomer: B. Rothberg (on call)
Instrument: MODS

Summary

At the sunset the sky is completely covered by clouds. Starting from 5:00 sky looks better, no thick clouds some thin cirrus, we open.

Night duration (12\xB0 el twilight) 4:10- 10:35 UT = 6 h 25m

Observing time: 4h 25min (69%)

Weather time loss: 2h m (31%)

technical time loss m *(0%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Spiniello KIDS1420 MODS1 dual grating 0.42h/0.42h mods1r.20180705.0005-0007 , mods1b.20180705.0002-0004  
Caccianiga GB6J163400 +321111 MODS1 red grating 0.5h/1.5h mods1r.20180705.0011-0012 completed
Caccianiga GB6J164104 +141546 MODS1 red grating 1.3h/1.3h mods1r.20180705.0016-0021 completed
Pancino Pandas 6 MODS1 dual grating 0.5h/0.5h mods1r.20180705.0025-0027 , mods1b.20180705.0005-0007 completed
Standard Feige 110 MODS1 dual grating, red grating      
Pancino Pandas 16 MODS1 dual grating 0.5h/0.5h   completed some clouds at the end