INAF queue observing, 2018 May 08-09

Observer: F. Cusano, A. Gargiulo
Telescope Operator: S. Allanson
Support Astronomer: O. Kuhn
Instrument:MODS, LUCI

Summary

At the sunset sky is clear
instruments: MODS2 red grating is not available all the other instruments are fine
Night duration (12\xB0 el twilight) 3:30- 11:00 UT = 7 h 30m

Observing time: 5h 40m (75%)

Weather time loss: 0h 30 (7%)

technical time loss 1h 20m (18%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
sky flat   LBC-R Y, i-sloan      
Gilli Mask 22 MODS1+LBC-R dual grating, i- sloan 2/4 h mods1r.20180509.0004-9, mods1b.20180509.0001-0006 1.3h of i images
Standard Feige 34 MODS1 dual grating, red grating      
Severgnini J1431 LUCI2 AO - K band 0.5 /0.6 h   target completed FWHM ~0.15", no psf star, check log
Prandoni USS202 LUCI1+2 Ks, J,z 0.9/0.9h, 1/1h, /1.7h   z images wih clouds, to be checked
Mods Call mask22 MODS1 dual grating     arc, flat Gilli
Luci cal flat LUCI2 AO - K band     Severgnini cal
LBC cal bino bias LBC-B-R       bias
Luci cal flat LUCI1+2 Ks, J, z     Prandoni cal
Mods Call ls MODS1 dual grating, red grating     arc, flat lfor s and standard

INAF queue observing, 2018 May 09-10

Observer: F. Cusano, A. Gargiulo
Telescope Operator: S. Allanson
Support Astronomer: O. Kuhn
Instrument: MODS

Summary

At the sunset sky is clear
instruments: MODS2 red grating is not available all the other instruments are fine
Night duration (12\xB0 el twilight) 3:30- 11:00 UT = 7 h 30m

Observing time: 7h 30m (100%)

Weather time loss: h (0%)

technical time loss * *(0%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
sky flat   LBC-R        
Luci cal darks Severgnini LUCI2     dit=5s, ndit=12, integ, lir
sky flat   LBC-R r     some z flats but count are low
Gilli mask 22 MODS1 +LBC-R dual grating, i 2/4h mods1r.20180510.0005-0010, mods1rb20180510.0002-0007 MODS completed ; i, z imaging completed for this field
Annibali R16 LBCs g, r 1/1h   NGC4068 completed
Annibali R30 LBCs g, r 0.66/1h   2 obs done
Dalessandro pal14 LBCs U, V, I 1.6/1.6h   completed; 1-2 LBC-B images are not good
Annibali R44 LBCs g, r /1h   1 ob done; images are good but sky bg is high for twilight, check
sky flat   LBC-bino g, SDT_U; V, I      
Luci cal darks LUCI1+2       darks for Prandoni imaging K, J, z

INAF queue observing, 2018 May 10-11

Observer: F. Cusano, A. Gargiulo
Telescope Operator: S. Allanson
Support Astronomer: O. Kuhn (on call)
Instrument: MODS

Summary

At the sunset there are some cirrus and thick clouds over the horizon. The wind is high, with gusts up to 17 m/s
instruments: MODS2 red grating is not available all the other instruments are fine
Night duration (12\xB0 el twilight) 3:30- 11:00 UT = 7 h 30m

Observing time: 4h 00m (53%)

Weather time loss: 3h 30m*(47%)*

technical time loss 0 (0%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Standard Feige 34 MODS1 dual grating, red grating      
Gilli mask36 MODS1+LBC-R dual grating + r 0.33/4h mods1r.20180511.0013, mods1b.20180511.0005 clouds, integrations stopped at 4:06
Spiniello KIDS1406 MODS1 dual grating 40 min mods1r.20180511.0019-0022, mods1b.20180511.0006-0009 completed; clouds during integration r.0019 and b.0006 do not use
Caccianiga GB6J162956 _095959 MODS1 red grating 1.8/1.8h mods1r.20180511.0026-0031 completed
Spiniello KIDS1453 MODS1 dual grating 24 min mods1r.20180511.0037&40, mods1b.20180511.0010-11 airmass > 1.5, some clouds
MODs cal slit flat 1.2" MODS1 dual grating     for Spiniello

INAF queue observing, 2018 May 11-12

Observer: F. Cusano, A. Gargiulo
Telescope Operator: S. Allanson
Support Astronomer: O. Kuhn (on call)
Instrument: MODS

Summary

At the sunset there are some cirrus. The wind is high, with gusts up to 35 m/s. The dome stay closed
instruments: MODS2 red grating is not available, LUCI2 can not be used for problem during day testing
Night duration (12\xB0 el twilight) 3:30- 11:00 UT = 7 h 30m

Observing time: 0h 45m (10%)

Weather time loss: 6h 45m (90%)*

technical time loss 0 (0%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
MODS call mask36 MODS1 dual grating     flat and arc
Caccianiga GB6J182917 MODS1 red grating 0.4/2.6 mods1r.20180512.0015 in twilight

INAF queue observing, 2018 May 12-13

Observer: F. Cusano, A. Gargiulo
Telescope Operator: S. Allanson
Support Astronomer: B. Rothberg (on call)
Instrument: LBC

Summary

At the sunset the sky is clear . The wind is at the limit, with gusts up to 20 m/s. We have restriction in pointing the telescope, e.g we can not point targets at south.
We start with LBC because Gilli target is on the south, with LBC we have more target in different directions
instruments: MODS2 red grating is not available, LUCI2 can be used today
Night duration (12\xB0 el twilight) 3:30- 11:00 UT = 7 h 30m

Observing time: 4h m (53%)

Weather time loss: 3h 30m (47%)

technical time loss 0 (0%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Palazzi 31 GRB1805 LBC Binocular 20/20m   completed
Annibali R30 LBC Binocular 0.33/1h   completed
Annibali R35 LBC Binocular 1/1h   completed
Annibali R29 LBC Binocular 0.4/1h    

INAF queue observing, 2018 May 13-14

Observer: F. Cusano, A. Gargiulo
Telescope Operator: S. Allanson
Support Astronomer: B. Rothberg (on call)
Instrument: LBC

Summary

At the sunset the sky is cloudy . The wind is above the limit, with gusts up to 23 m/s. The dome stay closed.
The weather condition improved, we open the dome at 6:00
instruments: MODS2 red grating is not available
Night duration (12\xB0 el twilight) 3:30- 11:00 UT = 7 h 30m

Observing time: 4h 00m (47%)

Weather time loss: 3h 30m (53%)

technical time loss 0 (0%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Spiniello KIDS1409 MODS1 dual grating 0.6/0.6h mods1r.20180514.0005-0007, mods1b.20180514.0002-0004 completed
Spiniello KIDS1421 MODS1 dual grating 0.2/0.6h mods1r.20180514.0011, mods1b.20180514.0005 script aborted for high wind
Caccianiga GB6J18291 MODS1 red grating 2.6/2.6h   completed
Topic revision: r4 - 04 Jul 2018, FeliceCusano