INAF queue observing, 2017 Sep 25-26

Observer: A. Rossi, R. Carini
Telescope Operator: G. Bechetti
Support Astronomer: O. Kuhn
Instrument: LBC

Summary

At the sunset the sky is clear. .

Night duration (12\xB0 el twilight) 2:00am- 12:20pm UT = 10 h 20m

Observing time: 10 hrs (97%)

Weather time loss: * *hrs (0%)

technical time loss 20 m (3%)

Data Summary

Project_RUN Objects Instrument Filter ExpTime Notes
Skayflats      
PHOT STD S113 LBC BVgr; VRrIiz   airmass about 1.4
Annibali R43 NGC6503 LBC g (blue channel), r ( red channel) 1 h completed
Cusano NW 1 LBC B (blue channel), V (channel) 42 m 6 obs done
Cusano NW 2 LBC B (blue channel), V (channel) 42 m 6 obs done
Cusano NW3 LBC B (blue channel), V (channel) 42 m 6 obs done
PHOT STD Galadi LBC BVgr (blue), Vrzi (red)   airmass about 1.1
Annibali R4 KK16 LBC g (blue channel), r ( red channel) 30 m completed
Annibali R5 KK17 LBC g (blue channel), r ( red channel) 40 m ob 1 and 2 done
PHOT STD SA95 LBC BVgr (blue), Vrzi (red)   airmass about 1.26
Skyflats          

INAF queue observing, 2017 Sep 26-27

Observer: A. Rossi, R. Carini
Telescope Operator: G. Bechetti
Support Astronomer: O. Kuhn
Instrument: LUCI1, LUCI2

Summary

At the sunset the sky is partially cloudy. At 11:10 (UT) the sky is totally covered, we stop the acquisition and close the dome

Night duration (12\xB0 el twilight) 2:00am- 12:20pm UT = 10 h 20m

Observing time: * *7.6hrs (73%)

Weather time loss: * *0.7h (7%)

technical time loss * *2h (20%)

Data Summary

Project_RUN Objects Instrument Filter ExpTime Notes
bias   LBC      
dark   LUCI1,2      
telluric A12 HIP106817 LUCI1,2 HKspec 2m no other telluric of Piconcelli visible
Piconcelli A11 1633+3629 LUCI1,2 HKspec 0.3 completed
new telluric A11 HIP87643 LUCI1,2 HKspec   much closer to A11, GOOD only for LUCI2
Piconcelli A12 2238-0808 LUCI1,2 HKspec 0.8 completed
telluric A12 HIP106817 LUCI1,2 2m HKspec 0.2  
Rossi GRB170714A too LUCI1,2 H 30+30min completed
Cusano NW1 LBC B (blue channel), V (red channel) 14min the second ob is not good
Cusano NW2 LBC B (blue channel), V (red channel) 14min the second ob is not good
Cusano NW3 LBC B (blue channel), V (red channel) 7min ob 7
Dotto 2004TK10 LBC BVg (blue), BzRI (red) 4m 30s repeated twice. sky cloudy and seeing bad
Calibration Piconcelli   LUCI HKspec    

INAF queue observing, 2017 Sep 27-28

Observer: A. Rossi, R. Carini
Telescope Operator: G. Bechetti
Support Astronomer: D. Thomson
Instrument: LUCI1, LUCI2

Summary

At the sunset the sky is cloudy and rainy.

Night duration (12\xB0 el twilight) 2:00am- 12:20pm UT = 10 h 20m

Observing time: * *1.66hrs (16%)

Weather time loss: * *h (81%)

technical time loss * *0.35h (3%)

Data Summary

Project_RUN Objects Instrument Filter ExpTime Notes
dark   LUCI1,2      
Antoniucci HIP 116229 LUCI1,2     telluric for V733 useless

INAF queue observing, 2017 Sep 28-29

Observer: A. Rossi, R. Carini
Telescope Operator: G. Bechetti
Support Astronomer: O. Kuhn
Instrument: LUCI1, LUCI2

Summary

At the sunset the sky is almost clear but the humidity is about 85%.

Night duration (12\xB0 el twilight) 2:00am- 12:20pm UT = 10 h 20m

Observing time: 1 hrs 20 m (13%)

Weather time loss: 9 h (87%)

technical time loss * *h (0%)

Data Summary

Project_RUN Objects Instrument Filter ExpTime Notes
Antoniucci8 V733 telluric LUCI zJ+HK   ok
Antoniucci8 V733 LUCI zJ+HK 80x4 in zJ, 30x4 in HK completed
Antoniucci8 V733 LUCI J 25s completed

INAF queue observing, 2017 Sep 29-30

Observer: A. Rossi, R. Carini
Telescope Operator: G. Bechetti
Support Astronomer: D. Thomson
Instrument: LUCI1, LUCI2

Summary

At the sunset the sky is partially clear, but high humidity

Night duration (12\xB0 el twilight) 2:00am- 12:20pm UT = 10 h 20m

Observing time: 0 hrs (%)

Weather time loss: 10 h 20 m (100%)

technical time loss * *h (%)

Data Summary

Project_RUN Objects Instrument Filter ExpTime Notes
DARKS   LUCI     Antoniucci V733, Moscadelli, Nisini, Massi, Antoniucci Ao, Vanzella
flats + arc   LUCI     Moscadelli, Nisini, Massi, Antoniucci Ao, Vanzella

INAF queue observing, 2017 Sep 30-Oct 1

Observer: A. Rossi, R. Carini
Telescope Operator: G. Bechetti
Support Astronomer: D. Thomson
Instrument: LUCI1, LUCI2

Summary

At the sunset the sky is clear. Wind from south (wind speed rear about 10-15 m/s)

Night duration (12\xB0 el twilight) 2:00am- 12:20pm UT = 10 h 20m

Observing time: 9 hrs 45 m (94%)

Weather time loss: * *h (%)

technical time loss 35 m (6%)

Data Summary

Project_RUN Objects Instrument Filter ExpTime Notes
DARKS   LUCI     Antoniucci
Moscadelli G100.3873 LUCI1,LUCI2 H2, Ks 1h + 10 m completed
standard F151 LUCI H2, K    
Massi B G092 LUCI1 AO H2, Ks 1h + 10 m completed
standard F151 LUCI1 H2    
Massi A G111 LUC1 AO H2, Ks 0.6h COMPLETED
Antoniucci_11 F Haro 6-10 LUCI1 AO FeII, H2, OH1060+z 1.2h completed
PSF standard GSC 01833-00704 LUCI1 AO FeII, H2    
telluric HIP 24266 LUCI1, LUCI2 HKspec    
Piconcelli A1 0415+0609 LUCI1,LUCI2 HKspec 0.5h completed
skyflat   LUCI1, LUCI2 Ks, H2   In LUCI2 misalignment, the flats are good for target at the center of FOV
-- %USERSIG{RobertaCarini - 2017-09-28}%

Comments

 
Topic revision: r5 - 17 May 2018, AndreaRossi
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback