INAF queue observing, 2016 May 02-03

Observer: R. Carini, M. Di Criscienzo
Telescope Operator: G. Bechetti
Support Astronomer: O. Kuhn
Instrument: LBC, MODS, LUCI

Summary

At the sunset the sky is clear.

Night duration (12\xB0 el twilight) 20:30-4:30 ( 03:30-11.30 UT) = 8 h 00m

Observing time: * 8h* (100%)

Weather time loss: * 0h* (0%)

technical time loss * h* (00%)

Data Summary

Project_RUN Objects Filter ExpTime Notes
Raimondo Uma II blue : Us, B, red : rsloan 22 m just the blue images are good
Photometric standard S104 blue: Us B V g, red: I r Vz R    
Photomeric standard GD153 blue:Us, B,V,g red:V z r I R    
Giallongo Virgo field 2 dual grating, r sloan 30 m mods lbc: 60sec0deg, 10sec0deg
Giallongo Virgo field 1 dual grating, r sloan 58 m 3 x900 sec and 1 x 760 sec (image no completed), lbc:60sec0deg,10sec0deg, 180sec0deg
standard feige 67 dual grating    
Beltran A4 G24.78+0.08 H2, Ks 1.6 h completed, at the bottom of the field is present a strange obscuration
standard FS-142 H2,Ks    
Flat field Giallongo    
bias LBC      
flat LUCI        

INAF queue observing, 2016 May 03-04

Observer: R. Carini, M. Di Criscienzo
Telescope Operator: D. Gonzalo-Huerta
Support Astronomer: O. Kuhn
Instrument: LBC, MODS

Summary

At the sunset the sky is clear. At the midnight the wind grows up At 8.15 the TO closes the dome

Night duration (12\xB0 el twilight) 20:30-4:30 ( 03:30-11.30 UT) = 8 h 00m

Observing time: * 4h 45m* (59%)

Weather time loss: * 3h 15m* (41%)

technical time loss * h* (00%)

Data Summary

Project_RUN Objects Filter ExpTime Notes
FLAT LBC   r, R, I in the red channel    
Giallongo Virgo field 2 dual grating, r sloan, 2h 15m the ob in LBC virgo_rsloan_180s_90deg.ob is not completed
Giallongo Virgo field 1 dual grating, r sloan 1 h the blue images are not good, in the red the spectra are visible
DARK LUCI        
MODS CALIB flat and arc for standard, bias dual grating    

INAF queue observing, 2016 May 04-05

Observer: R. Carini, M. Di Criscienzo
Telescope Operator: D. Gonzalo-Huerta
Support Astronomer: B. Rothberg on call
Instrument: LBC, MODS, LUCI

Summary

At the sunset the sky is clear. wind velocity 10m/s During the flat fields the wind is increasing At 5.10 the TO closes the dome, the wind rear is 22 m/s At 8:00 the wind decreased, the TO opens the dome

Night duration (12\xB0 el twilight) 20:30-4:30 ( 03:30-11.30 UT) = 8 h

Observing time: * 5 h 10 m* (64%)

Weather time loss: * 2h 50m* (36%)

technical time loss * h* (00%)

Data Summary

Project_RUN Objects Filter ExpTime Notes
FLAT LBC   I,z in the red channel    
Giallongo Virgo field 2 dual grating, rsloan 15 minutes completed the mods obs 3 and lbc ob 60s_90deg, seeing out of spec
mods bias        
standard S875-C_H2 H2,Ks        
Beltran A5 G28.87+0.07 H2, Ks 2h 15m completed

INAF queue observing, 2016 May 05-06

Observer: R. Carini, M. Di Criscienzo
Telescope Operator: D. Gonzalo-Huerta
Support Astronomer: O Kuhn on call
Instrument: LBC, MODS, LUCI

Summary

At the sunset there are some clouds and the wind is very strong, with gusts up to 21 m/s The dome is closed.

Night duration (12\xB0 el twilight) 20:30-4:30 ( 03:30-11.30 UT) = 8h 30m

Observing time: *0 * (%)

Weather time loss: * 8h* (100%)

technical time loss * h* (00%)

Data Summary

Project_RUN Objects Filter ExpTime Notes

-- %USERSIG{RobertaCarini - 2016-05-03}%

Comments

 
Topic revision: r4 - 25 May 2016, RobertaCarini
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.