INAF queue observing, 2024 February 15 - February 16

Observer: Ester Marini, Felice Cusano, Adriana Gargiulo
Support: Justin Rupert
Telescope operator : Josh Williams
Instrument: MODS, PEPSI

Summary

These observations have been performed in part by Justin Rupert with the support of LBT-Italia-obs remotely and in part in remote from Bologna by Felice Cusano and Adriana Gargiulo.

At sunset the sky is clear. We opened at 1:10UT. At the beginning the SHARK-VIS team starts observations, they operated until 03.00UT, they stop earlier for bad seeing.
We start with MODS and observe two targets for Biazzo, but for high seeing (>2") we switch to PEPSI at 05:54.

Night duration (12 degree - twilight) 02:00 - 13:00 UT = * 11h* * 00m*
Observing time: 9h 43min (79.3%)*
Weather time loss: 0 h 00 min (%)*
Technical time loss: 1 h 17min (11.7%)*
Shark-VIS time loss: 1h 00 min (9%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Notes
Biazzo ID77 MODS1-2 dual grating 1h/1.3h completed 1+1 exp more for bad seeing
Biazzo ID71 MODS1-2 dual grating 1h/2h completed double total exp for bad seeing
Bellazzini Gaia DR3 3802597128565139584 PEPSI D300/CD3-CD6 36min+36min S/N 101 (1st exp) and 114 (2nd exp) on CD3; 120 (1st exp) and 126 (2nd exp) on CD 6
Bellazzini Gaia DR3 758353308779172096 PEPSI D300/CD3-CD6 26min+26min try to halve the exp time because the S/N of the previous target were double than requested. S/N ~ 75 on CD3 and CD6
Bellazzini Gaia DR3 3786469869966389248 PEPSI D300/CD3-CD6 40min+40min S/N ~ 110 on CD3 and CD6
Bellazzini Gaia DR3 757340452411702784 PEPSI D300/CD3-CD6 40min+40min S/N ~ 110 on CD3 and CD6
Bellazzini Gaia DR3 3977532795798604032 PEPSI D300/CD3-CD6 40min+40min S/N ~ 115 on CD3 and CD6
Bellazzini Gaia DR3 3910516630077055872 PEPSI D300/CD3-CD6 50min+50min S/N ~ 120 on CD3 and CD6
Bellazzini Gaia DR3 4005409023335384832 PEPSI D300/CD3-CD6 40min+40min S/N ~ 115 on CD3 and ~130 on CD6
Bellazzini Gaia DR3 858619938780211328 PEPSI D300/CD3-CD6 10min+10min we did only 1 exp of 10+10 mins because of high background, but S/N~140
Calib   MODS1-2 dual,red    
Calib   LUCI1-2 darks    

Further details in the log by LBT-Italia at this link: https://drive.google.com/file/d/1Qfj8atkCfR-ocdpBnWzMlZ36wIrIwNaO/view?usp=sharing

and log from Justin Rupert: https://drive.google.com/file/d/1JVoWo_8IzkOPBXuezgSoeFv20Oy7g7Bc/view?usp=sharing

Summary of MODS science files: https://drive.google.com/file/d/1eMKtD6eSEMv0TMMIf1jayNhEpY7EurLZ/view?usp=sharing

Summary of MODS calib files: https://drive.google.com/file/d/1SZC3hlvr4kCbQS70w2uGvAzOs4EeiIeM/view?usp=sharing

Summary of LUCI calib files: https://drive.google.com/file/d/1XmpcvCfsDE0P2MZOJwfpZzWUlOEJ_D03/view?usp=sharing
Topic revision: r6 - 19 Feb 2024, FeliceCusano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback