-- AndreaRossi - 10 Jan 2024

INAF queue observing, 2024 January 09 - January 10

Observer: Andrea Rossi, Ester Marini
Support: Justin Rupert
Telescope operator : Steve Allanson
Instrument: SHARK, MODS, PEPSI

Summary

These observations have been performed by Justin Rupert with the support of LBT-Italia-obs remotely.

At sunset the sky is clear, we can open. SHARK took the first 3 hours of the night. We started observing with MODS at ~5 UT with clear sky and good seeing.

Night duration (12 degree - twilight) 01:22 - 13:24 UT = * 12h* * 02m*
Observing time: 7h 52min (65.4%)*
Weather time loss: 1h 10min (9.7%)*
Technical time loss: 0h 0min (0%)*
Shark-VIS time loss: 3h 0min (24.9%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Notes
Biazzo GD 71 MODS Bino dual grating    
Biazzo Sh2-284 MODS Bino dual grating 0.66h+0.66h LS_2 ID 23; DIMM <1.2"
Biazzo Sh2-284 MODS Bino dual grating 0.83h+0.83h LS_3 ID 30, we took 2 additional images due to flux loss (up to 3mag) during 2/3 of the script
Giannini Gaia22dbd MODS Bino imaging ugriz    
Giannini Gaia22dbd MODS Bino dual grating   seeing ~ 1-1.5", done with LUCI on 9Jan
Giannini Gaia21ebu MODS Bino imaging ugriz    
Giannini Gaia21ebu MODS Bino dual grating   variable seeing, 1"-1.8", done with LUCI on 9Jan
Bragaglia Gaia DR3 3451009727031458560 PEPSI BINO D300/CDIII-CDVI 500sec+500sec S/N=93 on CD3, 115 on CD5
Bellazzini Gaia DR3 3761587028476253824 PEPSI BINO D300/CDIII-CDVI 19 mins+19 mins S/N on CD3=88, increased exp time from 15 mins to 19mins due to variable seeing, DIMM up to 2.5"
Bellazzini Gaia DR3 Gaia DR3 723721338204385792 PEPSI BINO D300/CDIII-CDVI 20+20mins S/N on CD3=89
Bellazzini Gaia DR3 Gaia DR3 790338754868062208 PEPSI BINO D300/CDIII-CDVI 15+15mins stopped the exp 4 minutes earlier since we closed for the high wind, but the S/N on CD3 is 78 (requested was 40) so the spectra are ok
Detailed log at this link: https://drive.google.com/file/d/14XhE93nT_8GY0u5auc-zLmCY_VTYNDhQ/view?usp=sharing

Further details in the Log by Justin Rupert at this link: https://drive.google.com/file/d/1ZUlErGi4z8nmubbzkrjVOr6KykOeExkC/view?usp=sharing

Summary of MODS science files: https://drive.google.com/file/d/1WI_py56TcBLzybKBhsC0yxQzHRxdmdTs/view?usp=sharing

Summary of MODS calib files: https://drive.google.com/file/d/1aXd5xo5zqd9pCsXs-g3Oz2Z-iMb0anPs/view?usp=sharing
Topic revision: r6 - 11 Jan 2024, FeliceCusano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback