-- EsterMarini - 03 Jan 2024

INAF queue observing, 2024 January 02 - January 03

Observer: Ester Marini, Simona Paiano
Support: Andrew Cardwell
Telescope operator : Riccardo Ansaldi
Instrument: PEPSI

Summary

These observations have been performed by Andrew Cardwell with the support of LBT-Italia-obs remotely.

At sunset the sky is clear, but there is ice and snow on the dx shutter door, we can use SX only tonight. We also have pointing restrictions due to wind. The allSky camera is currently down and it was not possible to recover it for tonight. We open at 01:03 UT, but we close again for bad weather at 02:30UT and we re-open at 03:51UT.

Night duration (12 degree - twilight) 01:22 - 13:24 UT = * 12h* * 02m*
Observing time: 6 h 32 min (54%)*
Weather time loss: 5 h 00 min (42%)*
Technical time loss: 0 h 30 min (4%)*
Shark-VIS time loss: 0 h 00 min (0%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Notes
Bragaglia Gaia DR3 3451217539026976768 PEPSI MONO D300/CDIII-CDV 12mins S/N=109 on CD3 and 214 on CD5, exp time increased due to bad weather
Bragaglia Gaia DR3 3451182045417801216 PEPSI MONO D300/CDIII-CDV 12mins S/N=105 on CD3 and 200 on CD5, exp time increased due to bad weather
Bragaglia Gaia DR3 3451181323863324800 PEPSI MONO D300/CDIII-CDV 15mins S/N=150 on CD3 and 270 on CD5, exp time increased due to bad weather
Bragaglia Gaia DR3 3451201974065974400 PEPSI MONO D300/CDIII-CDV 16mins S/N=124 on CD3 and 213 on CD5, exp time increased due to bad weather
Bragaglia Gaia DR3 3451204718546726784 PEPSI MONO D300/CDIII-CDV 16mins S/N=152 on CD3 and 193 on CD5, exp time increased due to bad weather
Bragaglia Gaia DR3 3451206887508541184 PEPSI MONO D300/CDIII-CDV 25mins S/N=99 on CD3 and 142 on CD5, exp time increased due to bad weather
Bragaglia Gaia DR3 3451175512767145088 PEPSI MONO D300/CDIII-CDV 15mins exp time increased due to bad weather
Pino 55 cnc PEPSI MONO D300/CDI-CDIV   The observations started about 20 mins before the start of the transit.
Bellazzini Gaia DR3 3761587028476253824 PEPSI MONO D300/CDIII-CDVI 30 mins S/N=78 on CD3 and 114 on CD6
Detailed log at this link: https://drive.google.com/file/d/1Bds7fr6uGa23ELcL3kG2IoxAdZB1M76j/view?usp=sharing

Further details in the Log by Andrew Cardwell at this link: https://drive.google.com/file/d/1nH5aUsTjmivxns4Zk13NMt1FiLLf4iQS/view?usp=sharing

Summary of LUCI calib files: https://drive.google.com/file/d/1vjo72eIc7-0uO4t0OHK6LjsLcfQUq0XH/view?usp=sharing

Summary of MODS calib files: https://drive.google.com/file/d/1xMTuqsgLWbF6PTDVHZ1_5ksPCxClCAn4/view?usp=sharing