-- EsterMarini - 17 Sep 2023

INAF queue observing, 2023 September 16 - September 17

Observer: Ester Marini, Andrea Rossi
Support: Alex Becker
Telescope operator : David Gonzalez Huerta
Instrument: PEPSI

Summary

These observations have been performed for the first half of the night by LBTO personell under the supervision of Ester Marini of the LBT Italia observers, and for the second half by...

At sunset the sky is cloudy, but we can open. We start with PEPSI. Clouds, bad seeing and high humidity prevented us to be open all night. See logs for details

Night duration (12 degree - twilight) 02:15 - 12:15 UT = * 10h* * 00m*
Observing time: 05 h 10 min (52%)*
Weather time loss: 04 h 50 min (48%)*
Technical time loss: 00 h 00 min (0%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Marini IRAS 18062+2410 PEPSI CDI-CDIV 25+25min   S/N~90 on CDI, ~170 on CD IV
Marini IRAS 18062+2410 PEPSI CDIII-CDVI 12+12min   S/N~110 on CDIII, ~100 on CD VI, increased exp time from 8 to 12mins due to clouds
Marini IRAS 19200++3457 PEPSI CDI-CDIV 2+2hr   S/N~350 on CDI, ~790 on CD IV, exp time increased from 1hr23min to 2hr due heavy mag extinction
Marini IRAS 19200++3457 PEPSI CDIII-CDVI 11+11min   S/N~221 on CDIII, ~175 on CD VI
Marini IRAS 19343-2926 PEPSI CDI-CDIV 33+33min   S/N ~70 on CD1, ~240 on CDIV, maybe blue bad for jump in seeing+humidity to be repeated
Marini IRAS 19343-2926 PEPSI CDII-CDV 26+26min   S/N ~120 on CDII, ~250 on CDV, exp time from 21 to 26mins for humidity+highseeing
Marini IRAS 19343-2926 PEPSI CDIII-CDVI 14+14min   S/N ~120 on CDIII , ~150 on CDVI, exp time from 11 to 14mins for humidity+highseeing
Marini IRAS 20462+3416 PEPSI CDI-CDIV 25+25min   S/N 120 on CDI, 320 on CDIV, exp time from 17 too 25 for clouds
Marini IRAS 20572+4919 PEPSI CDI-CDIV 5+5 min   S/N 50 on CDI, 70 on CDIV, stopped , we had to close, to be repeated
Calib   MODS dual grating     dual grating arcs+flats, 0.8", 1.2",5" slits and slitless
Detailed log at this link: https://drive.google.com/file/d/1x21mYIyNgR6drXxPfqkMMHCWLqNV8adf/view?usp=sharing

Further details in the Log by Alex Backer at this link: https://drive.google.com/file/d/13kr9TMw1_1VJknl8eyocMiY0keWCzsyF/view?usp=sharing

Summary of MODS calib files: https://drive.google.com/file/d/1S-Q4xr2Pdz0rPnEbuLsooufSYbDL-8b_/view?usp=sharing

Summary of PEPSI science files: https://drive.google.com/file/d/139Q22Wo7Xv2RRzwRV8O79Wd1Hk_zWyhP/view?usp=sharing
Topic revision: r13 - 21 Sep 2023, FeliceCusano