-- EsterMarini - 29 May 2023

INAF queue observing, 2023 May 28 - May 29

Observer: Ester Marini, Felice Cusano
Telescope Operator: Steve Allanson
SA : Jennifer Power
Instrument: MODS

Summary

These observations have been performed by Ester Marini and Felice Cusano from the summit of the LBT.
At sunset the sky is clear and we can open. A problem occurred in initializing the camera in LUCI1, with the camera stuck in N30 position. Dave and Jenny tried to solve it but without success, LUCI cannot be used tonight. We used MODS for the whole night.

Night duration (12 degree - twilight) 03:40 - 11:10 UT = * 7h* * 30m*
Observing time: 7h 30min ( 100%)*
Weather time loss: 0h 0min ( 0%)*
Technical time loss: 0h 0min ( 0%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calibration dual imag flats MODS1-2        
Severgnini Mrk147 dual grating MODS1-2 0.41/0.33hr   *_1, *_2 done, we took 1 more exp of *_1 since we started very early in the night, seeing ~0.8"
Severgnini Mrk22 dual grating MODS1-2 1.33/1.33.hr   seeing ~ 0.8-1.1"
Vietri J1421 red+blue grating MODS1-2 0.25hr   seeing ~ 0.7" , we did the 1/4 exp that we missed yesterday night
Severgnini Mrk153 dual grating MODS1-2 0.5/0.5hr   *_1, *_2, *_3 done, average seeing ~1.1"
Vietri J1538 red+blue grating MODS1-2 0.25hr   seeing ~ 0.8-1.1", we did the 1/4 exp that we missed yesterday night
Ighina PSJ1321 red grating MODS1-2 2/2hr   variable seeing ~ 1-1.5", done with the 1" slit
Giannini Gaia23bab MODS1-2 dual ima - ugriz 0.05/0.05hr   seeing ~ 1"
STD BD+33 MODS1-2 red-blue grating     for Vietri
STD BD+33 MODS1-2 dual grating      
Giannini Gaia20cwd MODS1-2 dual grating 0.5/0.5hr   average seeing ~ 1.2"
Giannini Gaia20cwd MODS1-2 dual ima - ugriz 0.1/0.1hr   seeing ~ 0.8-1"
Severgnini Mrk306 dual grating MODS1-2 0.75/0.75hr   average seeing ~ 1", with 1.3" during the first exp, but we could not take additional exp because we were pointing to te east
CALIB flat ima LUCI2 KS     for Gilli_AO
CALIB flat ima LUCI2 K     for Severgnini_AO
CALIB flat ima LUCI2 H2,H,J     for Caratti_DDT AO
CALIB flat ima LUCI2 JH     for Palazzi
CALIB flat arc LUCI2 G210 - K     for Caratti_AO
Detailed log by Felice and Ester at this link: https://drive.google.com/file/d/122GfpGj9wfFvdFmlHsPL9RSllGOD3PUm/view?usp=sharing

Summary of MODS science files: https://drive.google.com/file/d/11GzbOLKRl3hLD28AvHjWDdvsDufHpzb9/view?usp=sharing

Summary of LUCI calib files: https://drive.google.com/file/d/1e9077fUMuMjPKV9DR2sOh_DHrEWnPAFY/view?usp=sharing
Topic revision: r7 - 04 Jun 2023, FeliceCusano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback