INAF queue observing, 2023 May 27 - May 28

Observer: Ester Marini, Felice Cusano
Telescope Operator: Steve Allanson
SA : Jennifer Power
Instrument: MODS

Summary

These observations have been performed by Ester Marini and Felice Cusano from the summit of the LBT.
At sunset the sky is clear and wind is below the limit. We start with MODS.
It was a good night with no clouds. Some parts of the night were affected by variable seeing

Night duration (12 degree - twilight) 03:40 - 11:10 UT = * 7h* * 30m*
Observing time: 7h 30min ( 100%)*
Weather time loss: 0h 0min ( 0%)*
Technical time loss: 0h 0min ( 0%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calibration slitflat MODS1-2 dual     1.2" slit flat
La Franca B2 0917+23 MODS1-2 dual grating 0.5/0.4hr   1 more exp due to variable seeing and the less efficiency of MODS1
STD Feige 34 MODS1-2 dual grating     for La Franca
Severgnini Mrk147 MODS1-2 dual grating     *_1, to be done again to due high seeing
Vietri J1421 MODS1-2 red+blue grating 1/1hr   seeing ~0.9-1.2", 1/4 of the spec is not usable because the target fell in the gap of the slit (see log for details)
STD Hz44 MODS1-2 red+blue grating     for Vietri
STD Hz44 MODS1-2 red grating     for Decarli
Vietri J1538 MODS1-2 red+blue grating 1/1hr   seeing ~0.9-1.2", 1/4 of the spec is not usable because the target fell in the gap of the slit (see log for details)
Ighina PSJ1638 MODS1-2 red grating 1.7/1.7hr   seeing ~0.9-1.2"
Decarli PSO009.61 MODS1-2 red grating 0.33/0.33hr   seeing ~1.5"
Decarli PSO331.93 MODS1-2 red grating 0.33/0.33hr   seeing ~1.5-1.2"
Giannini Gaia23bab MODS1-2 dual grating 0.5/0.5hr   seeing ~0.7"
Giannini Gaia23bab MODS1-2 dual ima- ugriz 0.05/0.05hr   seeing ~0.7"
Calibration slitflat MODS1-2 dual     0.8" slit flat
Calibration slitflat MODS1-2 red     0.6" slit flat
Calibration slitflat MODS1-2 blue     0.6" slit flat
Calibration slitflat MODS1-2 red     1.2" slit flat
Calibration slitflat MODS1-2 red     1.0" slit flat
Detailed log by Felice and Ester at this link: https://drive.google.com/file/d/1M39MMoPidaEjfQd4dLh0O1dNDT4ORyy9/view?usp=sharing

Summary of MODS science files: https://drive.google.com/file/d/1At7gkt7lnc-bNjlg89RT9dWGfIMjvJXv/view?usp=sharing
Summary of MODS calib files: https://drive.google.com/file/d/1RgCDktfmZq7YGx6piDXd74c8bK5Do2zl/view?usp=sharing
more MODS calib made by Jenny before our run: https://docs.google.com/document/d/1xjnbeHl876A9J2PPJKz76bryVFW_JP9q3K_dCzZTwN8/edit?usp=sharing
Topic revision: r9 - 04 Jun 2023, FeliceCusano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.