INAF queue observing, 2023 Apr 20 - Apr 21

Observer: Olga Kuhn
Telescope Operator: David Gonzales Huerta
Astronomers from Italy: Felice Cusano, Ester Marini, Andrea Rossi, Simona Paiano
Instrument: MODS-BINO, LBC

Summary

These observations have been performed by Olga Kuhn from LBTO, Andrea Rossi and then Felice Cusano connected from Italy with the support of Ester Marini and Simona Paiano and other LBTO personnel.
At sunset the sky is clear and wind is from NW but within constraints. We start with MODS1+2.
We switch to LBC to complete Belladitta, but conditions were not good enough for this program, so we had to go back to MODS.

Night duration (12 degree - twilight) 02:50 - 11:50 UT = * 9h* * 00m*
Observing time: 9 h 0 min (100 %)*
Weather time loss: 0 h 0 min (0 %)*
Technical time loss: 0 h 0 min (0 %)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
STD Feige34 MODS1+2 red grating     for Ighina and Decarli
STD Feige34 MODS1+2 dual grating     for Mazzolari and Severgnini
Mazzolari ID774 MODS1+2 dual grating 2.5h/2h   this was done for the problem occurred on MODS1. We took one more exposure due to bad seeing during the first and second one
Belladitta_LBTB J1037 LBC-BINO   0.6h   has to be done again, FWHM on image ~2"
D'Onofrio NGC4307 LBC-BINO   0.5h/1.5h   done NGC4307_g_r_1.xml with fwhm=1", second obs stopped for high seeing
Decarli PSO0234.55 MODS1+2 red grating 2X(0.16h+0.16h)   Seeing~1.3" double exp time for variable seeing completed
Decarli PSO0250.58 MODS1+2 red grating (0.25h+0.25h)   Seeing~1"
Decarli PSO0262.67 MODS1+2 red grating (0.25h+0.25h)   Seeing~1"
Ighina PSJ1614 MODS1+2 red grating (0.6h+0.6h)   Used slit = 1" , Seeing~1" completed
calibration   MODS1+2 dual grating     slit 1.2"
calibration Bias LBC-Bino        
Detailed log by Andrea, Ester, Felice and Simona at this link: https://drive.google.com/file/d/1BEHfNokHN3HgdMEhtsHT391WrVeySt_e/view?usp=sharing

Detailed log by Olga Kuhn at this link: https://drive.google.com/file/d/1l9xv5NoCNtALmDGOYTXAvuq0iKOnaXQl/view?usp=sharing

Summary of MODS science files: https://drive.google.com/file/d/1s1sRwl4JPHBTLIhGLbG9RDAX33pR_rcw/view?usp=sharing
Summary of MODS calib files: https://drive.google.com/file/d/1ixHtY8Ve_WdfMrSCQIOXFlFYVdyyHVl5/view?usp=sharing

Summary of LBC science files: https://drive.google.com/file/d/1dS2EJxOUEz0fr6jMIL7RcB6CfkA9tUjB/view?usp=sharing
Summary of LBC calib files: https://drive.google.com/file/d/1pVMR39j_x9o3K35okTqJdQHxdlPkx55Q/view?usp=sharing
Topic revision: r16 - 28 May 2023, FeliceCusano