-- EsterMarini - 18 Apr 2023

INAF queue observing, 2023 Apr 17 - Apr 18

Observer: Felice Cusano and Olga Kuhn
Telescope Operator: Steve Allanson
Astronomers from Italy: Felice Cusano, Ester Marini, Andrea Rossi, Simona Paiano
Instrument: LUCI-BINO

Summary

These observations have been performed by Felice Cusano connected from Italy with the support of Ester Marini, Simona Paiano and the LBTO personnel.
At sunset the sky is clear and the wind is well below the limit. We open.

Night duration (12 degree - twilight) 02:50 - 11:50 UT = * 9h* * 00m*
Observing time: 8 h 30 min (94.4 %)*
Weather time loss: 0 h 30 min (5.6 %)*
Technical time loss: 0 h 0 min (0 %)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
STD HD106038 LUCI1+2 G210+K     for La Barbera
STD HD106038 LUCI1+2 G210+H     for La Barbera
STD HD106038 LUCI1+2 G200+zJ     for La Barbera
Telluric HIP62745 LUCI1+2 G210+K     for La Barbera
La Barbera M87 LUCI1+2 G210+K 1.45/1.45h   seeing ~ 0.8-1" , K band completed
Telluric HIP62745 LUCI1+2 G210+K     for La Barbera
Telluric HIP62745 LUCI1+2 G210+H     for La Barbera
La Barbera M87 LUCI1+2 G210+H 1.45h/1.45h   seeing ~1" , H band completed
Telluric HIP62745 LUCI1+2 G210+H     for La Barbera
Telluric HIP71172 LUCI1+2 G200+zJ     for Bisogni
Bisogni W5 LUCI1+2 G200+zJ 1.66/1.33h   seeing ~1", we took 2 exp more (first of them is not useful) since we had the LUCI1/AGw patrol field issue
Severgnini Mrk219 MODS1+2 dual grating 0.33/0.66h   only *_1 done. Seeing is to high for this program ~1.1-1.5"
STD HZ44 MODS1+2 dual grating     only 2/3 exposures done, since we close for high particle counts
STD HZ44 MODS1+2 red grating     for Ighina and Decarli
Decarli PSO254.74 MODS1+2 red grating     seeing ~1.2"
Ighina PSJ1645 MODS1+2 red grating 1.5/2h   done with 1" slit, seeing variable see the log for details. Took 3 out of 4 exps for high background
calib arc and flat LUCI1+2 G200+zJ     slit 1"
calib arc and flat LUCI1+2 G210+H and K     slit 0.5"
calib imag flat LUCI1+2 H and K      
calib arc, flat and slitless MODS1+2 dual, red     do not use mods1r.20230418.0042-43-44, saturated
Detailed log by Ester and Felice at this link:

https://drive.google.com/file/d/11A3hCByxqJRCebYcFvF4xMG8teKCRcFh/view?usp=sharing

Detailed log by Olga Kuhn at this link:

https://drive.google.com/file/d/12pZwZtHXGgaZnpVeXMdfOKE_aZZA7IFs/view?usp=sharing

Summary of LUCI science files: https://drive.google.com/file/d/1FXyxBCFb5fxhMmLi_OzRzBLDqVzz8CCM/view?usp=sharing
Summary of LUCI calib files: https://drive.google.com/file/d/1b23BSya0zvTHd6YdP5dnWUFQdWBSlK5M/view?usp=sharing

Summary of MODS science files: https://drive.google.com/file/d/1pcuOXNRnALmnmLPyN8vtvOlK24_5uVuL/view?usp=sharing
Summary of MODS calib files: https://drive.google.com/file/d/1V7vDpJrEg7u8Ku0Lq9-fvI3vweGxZxgu/view?usp=sharing