INAF queue observing, 2023 Mar 28 - Mar 29

Observer: Olga Kuhn
Telescope Operator: D. Gonzalez Huerta
Astronomers from Italy: Felice Cusano, Ester Marini, Andrea Rossi and Simona Paiano
Instrument: LUCI

Summary

These observations have been performed by LBT Italian observers connected from Italy with the support of LBTO personnel.
At the sunset the sky is clear we can open, At about 08:30 we had to switch to MODS because the wind prevented us to observe
most of the LUCI high priority targets. We closed at 11:20 for high wind.

Night duration (12 degree - twilight) 02:40 - 12:10 UT = * 09h* * 30m*
Observing time: 7 h 0 min (73%)*
Weather time loss: 1 h 0 min (11%)*
Technical time loss: 1 h 30 min (16%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calibrations   MODS1+2        
Calibrations   LUCI1+2        
Gilli QSO LUCI1+AO Ks 1.5h   seeing 1", stop for high wind facing the target
Standard HD75555 LUCI1-2 G210-K and H     for La Barber; but we can not go to science target for the wind
Telluric HIP65599 LUCI1-2 G200-HKspec     for Piconcelli
Piconcelli J1359 LUCI1-2 G200-HKspec 1.25h   seeing 0.9", stop for high wind facing the target
Standard Hz44 MODS1-2 dual and red grating      
Severgnini Mrk799 MODS1-2 dual grating 0.33h   completed
Severgnini Mrk66 MODS1-2 dual grating 0.33h   only done acq_1 e sci_1, stopped for high wind
Detailed log by Felice and Andrea at this link: https://drive.google.com/file/d/13OLH8IvSanF-_ElParnbxMcMe8lo4rYB/view?usp=sharing

Detailed log by O. Khun at this link: https://drive.google.com/file/d/1X2EVzVlJpNC6pfWiKyyyxoa-fvEN1HKr/view?usp=sharing

Summary of LUCI science files: https://drive.google.com/file/d/19DI7KF1i_JNzQ7Wk05rw9yqEcyUozMkx/view?usp=sharing

Summary of MODS science files: https://drive.google.com/file/d/17xui9ryCv8Hu5vbbCVGAelsHapRTUlyp/view?usp=sharing

Summary of LUCI calibration files: (note La Barbera calibration are not good, see next night) https://drive.google.com/file/d/11HUrujhAFrUUDrOWuLlaH0teFGM7CNiz/view?usp=sharing

Summary of MODS calibrations files: (note the files taken at the end of the night after UT 13 are not good) https://drive.google.com/file/d/1wuDZ_G3Ad_yOIS0y35f6W1hykmUSgdCt/view?usp=sharing
Topic revision: r11 - 03 Apr 2023, FeliceCusano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.