INAF queue observing, 2022 Dec 16 - Dec 17

Observer: Jenny Power
Telescope Operator: David Gonzalez Huerta
Astronomers from Italy: Andrea Rossi and Ester Marini
Instrument: MODS

Summary

Due to the Covid-19 pandemic situation these observations have been performed by LBTO personnel
through the indications of LBT Italian observers connected from Italy.

Dense passing cirrus at sunset. After several IT technical issues, we start with MODS at ~3UT and with clear sky.

Night duration (12 degree - twilight) 01:20 - 13:20 UT = * 12h* * 00m*
half night Observing time: 8h 30min (70.8%)*
Weather time loss: 0h 0min (0%)*
Technical time loss: 3h 30min (29.2%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
STD Feige110 MODS1+2 dualgrating    
Grazian_16 Q1137257 MODS1+2 dualgrating, slit 1.2" 0.25hrs  
Giannini Gaia21csu MODS1+2 dualgrating, slit 0.8" 0.5hrs  
Grazian_16 Q119922839 MODS1+2 dualgrating, slit 1.2" 0.25hrs  
Marini IRAS 06556+1623 PEPSI-PFU CD3-CD6   seeing ~240 on CD6 and ~145 on CD3
Bellazzini GAIA DR3 3141565377831217792 PEPSI-PFU CD3-CD6   S/N ~60 on CD3 and ~135 on CD6
Bellazzini GAIA DR3 706235083234715648 PEPSI-PFU CD3-CD6   S/N ~65 on CD3 and ~140 on CD6
Bellazzini GAIA DR3 699104612889183488 PEPSI-PFU CD3-CD6   S/N ~60 on CD3 and ~130 on CD6
Bellazzini GAIA DR3 935181372963296896 PEPSI-PFU CD3-CD6   S/N ~70 on CD3 and ~150 on CD6
Bellazzini GAIA DR3 950636967397629568 PEPSI-PFU CD3-CD6   S/N ~70 on CD3 and ~140 on CD6
Bellazzini GAIA DR3 5763923768536566656 PEPSI-PFU CD3-CD6   S/N ~65 on CD3 and ~130 on CD6
Bellazzini GAIA DR3 38391655109152738 PEPSI-PFU CD3-CD6   S/N ~70 on CD3 and ~140 on CD6
Bellazzini GAIA DR3 589663073749934208 PEPSI-PFU CD3-CD6   S/N ~75 on CD3 and ~140 on CD6
Decarli PSO105.78 MODS1-2 red grating   seeing ~1", no visible spectrum on mods2!!
STD Feige 34 MODS1-2 red grating   for Decarli, 1 exp: trace 7 times higher that background; 2 exp: still a decent trace, 3 exp: trace 2 times higher than background on both mods1-2
Detailed log by Jenny at this link:

https://drive.google.com/file/d/1BTGPuTRaDJzvqoK3SS8mXUmkHfCOWP41/view?usp=sharing

summary of MODS science files: https://drive.google.com/file/d/1QRIdeLrPa7AorfxxCA_y-TmQSmOcjX0p/view?usp=sharing
summary of MODS calib files: https://drive.google.com/file/d/1QjYmiO63VmP2b1N0Gx_PU-omHOGf5WLO/view?usp=sharing
Topic revision: r10 - 21 Jan 2023, FeliceCusano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.