-- EsterMarini - 11 Nov 2022

INAF queue observing, 2022 Nov 11 - Nov 12

Observer: Andrew Cardwell
Telescope Operator: Josh Williams
Astronomers from Italy: Ester Marini and Felice Cusano
Instrument: LUCI and PEPSI

Summary

Due to the Covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers connected from Italy.

At sunset the sky is partly cloudy and satellite shows that more clouds are coming. We open at 00:28UT.

Night duration (12 degree - twilight) 01:20 - 12:50 UT = * 11h* * 30m*
Observing time: 5 h 40 min (50%)*
Weather time loss: 3 h 50 min (33%)*
Technical time loss: 2 h 00 min (17%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calib           see log
Rossi DDT GRB221009A LUCI1+2 KK imaging 0.33h/0.33h   IQ~0.5"
Marini Hen1-5(IRAS 20097+2010) PEPSI-PFU CD3-6 0.33h/0.1h   S/N~97 on CD6, ~60 on CD3. we increased the exp time from 3 to 10 due to clouds, but S/N still under requirement
Bellazzini Gaia DR3 2633862890108653696 PEPSI-PFU CD3-6     S/N~100 on CD6, ~80 on CD3 in the first exposure. We did 2x30min due to clouds.
Bellazzini Gaia DR3 1920638357490522752 PEPSI-PFU CD3-6     S/N~100 on CD6 and ~85 on CD3 on the first exposure
Bellazzini Gaia DR3 2547150425277019008 PEPSI-PFU CD3-6     S/N ~90 on CD 6 and ~75 on CD3 on the first exposure
Bellazzini Gaia DR3 2540596442621813760 PEPSI-PFU CD3-6     S/N
Tozzi_DDT lens LUCI1-2 G210-K 0.83h/2h   only 5 exp done, then close for humidiy, no telluric observed, but the point source in the slit can be use as a reference

Detailed log by Andrew at this link:

https://drive.google.com/file/d/1Ar_7Zt3OTMYslGQ3P2qsmDBXm1hhtJYG/view?usp=sharing
Topic revision: r5 - 14 Nov 2022, FeliceCusano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback