-- EsterMarini - 21 Oct 2022

INAF queue observing, 2022 Oct 20 - Oct 21

Observer: Alexander Becker
Telescope Operator: Josh Williams
Astronomers from Italy: Ester Marini and Simona Paiano
Instrument: PEPSI - MODS

Summary

Due to the Covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers connected from Italy.

At sunset the sky is clear, Temp 5.2C, Humidity 74%, Wind ~6.5m/s@200, we open.

Night duration (12 degree - twilight) 02:09 - 12:15 UT = * 10h* * 30m*
Observing time: 9 h 43 min (96%)*
Weather time loss: 0 h 00 min (0%)*
Technical time loss: 0 h 23 min (4%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Bellazzini GAIA DR3 4469752128283177728 PEPSI-PFU CD3-6 0.67hr   S/N~150 in the red, ~105 in the blue
Bellazzini GAIA DR3 2091117463580583808 PEPSI-PFU CD3-6 0.83hr   S/N~150 in the red, ~105 in the blue
Bellazzini GAIA RD3 4209725148797054592 PEPSI-PFU CD3-6 0.67hr   S/N~140 on the red, ~115 on the blue
Bellazzini GAIA RD3 4245522468554091904 PEPSI-PFU CD3-6 1hr   S/N~130 in the red, ~90 in the blue, we have been off target for 8 minutes, we took 8 minutes more
Bellazzini GAIA RD3 1879225011511631232 PEPSI-PFU CD3-6 0.83hr   S/N~130 on the red, ~115 on the blue
Bellazzini GAIA RD3 2626971670917198080 PEPSI-PFU CD3-6 0.67hr   S/N~150 on the red, ~110 on the blue
Bellazzini GAIA RD3 2652780576075420544 PEPSI-PFU CD3-6 0.67hr   S/N~150 on the red, ~120 on the blue
STD Feige110 MODS blue grating   mods1-2b.20221021.0005-0007.fits for Pentericci
Pentericci UDS2 MODS-MOS blue grating 2h + 2h mods1-2b.20221021.0011-0016.fits UDS2-4 done, seeing~0.6" at the beginning, USD2-5 done, see~0.5", stable during the obs.
Pentericci UDS1 MODS-MOS blue grating 2h + 2h mods1-2b.20221021.0020-0025.fits UDS1-1 done , seeing~0.6", UDS1-2 seeing~0.7" , last exposure some issues with the guiding, probably to reject!!
Severgnini Mrk365 MODS-LS dual grating 0.16h + 0.16h mods1-2b.20221021.0026-0027.fits , mods1-2r.20221021.0006-0007.fits seeing~0.8
Severgnini MCG-06 MODS-LS dual grating 0.16h + 0.16h mods1-2b.20221021.0028-0029.fits , mods1-2r.20221021.0011-0012.fits seeing~0.9
Severgnini GD71 Std star MODS-LS dual grating   mods1-2b.20221021.0030-0032.fits , mods1-2r.20221021.0015-0017.fits  
De Carli GD71 Std star MODS-LS red grating   mods1-2r.20221021.0018-0020.fits  
Detailed log by Alexander Becker at this link:

https://drive.google.com/file/d/1oeLm5_bMtb5rKmCHIVpuX8yy0LY-sQzI/view?usp=sharing