-- FeliceCusano - 19 Apr 2022

INAF queue observing, 2022 Apr 18 - Apr 19

Observer: A. Cardwell
Telescope Operator: S. Allanson
Astronomers from Italy: Felice Cusano, Simona Paiano (Ester Marini)
Instrument: LUCI

Summary

Due to the Covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F. Cusano, A. Rossi, S. Paiano and E. Marini) connected from Italy.

At the sunset the sky is cover by clouds. We start with bino LUCI and backup programs. We can not use PEPSI for maintenance.
LBCB is offline due to some problems.

Night duration (12 degree - twilight) 02:55 - 11:55 UT = 9 h 00 m
Observing time: 5 h 18 min (59%)*
Weather time loss: 3 h 42 min (41%)*
Technical time loss: 0 h 00 min (0%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calibration            
Palazzi HIP42853 LUCI1-2 zj-HK     telluric Palazzi
Palazzi SLSN2020abjc LUCI1-2 zJ 1.2h+1.2h   4 exp more for clouds, seeing~1"
Palazzi SLSN2020abjc LUCI1-2 Hk 1.3h+1.3h luci1.20220419.0050.fits-luci1.20220419.0091.fits /luci2.20220419.0050.fits-luci2.20220419.0091.fits seeing has been slowly degrading (up to 1.5"), 4 exp more for clouds
Palazzi SLSN2020abjc LUCI1-2 J, H imaging   luci1.20220419.0092.fits-luci1.20220419.0119.fits / luci2.20220419.0092.fits-luci2.20220419.0119.fits High cloudiness!!
Izzo SN2022gnz LUCI1-2 J, H imaging 0.35h+0.35h luci1.20220419.0120.fits-luci1.20220419.0144.fits / luci2.20220419.0120.fits-luci2.20220419.0144.fits (12 exp in J and 13 exp in H) seeing=1.5"-2"
Calibration   LUCI1-2 domeflat H+J fraternal      
Calib-Palazzi   MODS1-2 dual-arcs      
Calib-Palazzi   MODS1-2 dual-slitless      
Calib-Palazzi   LUCI1-2 flats-arcs HK200-1"-fraternal      
Calib-Palazzi   LUCI1-2 flats J H - fraternal      
Calib-Palazzi   MODS1-2 dual-flat 1.2"      
Calib-Piconcelli   LUCI1-2 flatarcs-zJ200-lambda1p17 fraternal      
Calib-Piconcelli   LUCI1-2 flatarcs-HK200-lambda1p93 fraternal      
Calib-Polletta   LUCI1-2 flatarcs- id963032 fraternal      
Calib-Mannucci   MODS1-2 flats 0.6"      

Detailed log by Andrew Cardwell at this link:

https://drive.google.com/file/d/1RpUVZNyZEMjSV9DEGCoaoz0-LwTJS2rG/view?usp=sharing

Notes

Topic revision: r6 - 26 Apr 2022, FeliceCusano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.