-- SimonaPaiano - 03 Apr 2022

INAF queue observing, 2022 Apr 02 - Apr 03

Observer: A. Cardwell
Telescope Operator: S. Allanson
Astronomers from Italy: Simona Paiano, Ester Marini, Andrea Rossi
Instrument: MODS, LBC

Summary

Due to the Covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F. Cusano, A. Rossi, S. Paiano and E. Marini) connected from Italy.

Night duration (12 degree - twilight) 02:35 - 12:10 UT = 9 h 35 m
Observing time: 9h 25min (98%)*
Weather time loss: 0h 0min (0%)*
Technical time loss: 0h 10min (2%)*

At the sunset the sky is clear.
Starting with MODS seeing 1" at 02:09 UT.

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
CALIBRATION BIAS LBC1-2 BIAS      
CALIBRATION FLAT MODS1-2 slitflat red grating 5arcsec     for Saracco
CALIBRATION FLAT MODS1-2 slitless red grating     for Saracco
CALIBRATION ARCS MODS1-2 arcs red grating     for Saracco
Standard Feige34 MODS1-2 red grating, dual grating     for Saracco, seeing ~1"
Saracco RDCS0910 MODS1-2 red grating 6.5/11h mods[1-2]r.20220403.0026-0038 seeing 0.7"- exp11,12: ~0.5mag extinction, took 1 more
Bellazzini G759379595509109632 PEPSI1-2 CD3-6 25/15min each side   SNR 165 on CD6; cirrus
Bellazzini G1580291233258597888 PEPSI1-2 CD3-6 30/15min each side   SNR 152 on CD6; cirrus
Bellazzini G1565515721127340928 PEPSI1-2 CD3-6 20/15min each side   SNR 142 on CD6; thin clouds
Bellazzini G1677649895521907200 PEPSI1-2 CD3-6 20/15min each side   SNR 94 on CD6; thin clouds
Bellazzini G1156158780372565120 PEPSI1-2 CD3-6 40/15min each side   SNR 131 on CD6; thin clouds
Bellazzini G4453220730438373504 PEPSI1-2 CD3-6 40/15min each side   SNR 150 on CD6; thin clouds
Rainer Kepler-14 PEPSI1-2 CD1-4 20/7min each side   SNR 160 on CD5; clouds
Rainer Kepler-14 PEPSI1-2 CD2-5 25/7min each side   SNR 240; thin clouds
Rainer Kepler-14 PEPSI1-2 CD3-6 25/7min each side   SNR~120 clouds
CALIBRATION FLAT MODS1-2 MOS flat red grating     for Saracco
CALIBRATION   PEPSI1-2        
CALIBRATION BIAS MODS1-2 3x3,8x3      

Detailed log by Andrew Cardwell at this link: https://drive.google.com/file/d/1Ne2ufXcSUvasQzUaAJ6-8DJ9rghJT2Ou/view?usp=sharing