Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F. Cusano, A. Rossi, S. Paiano and E. Marini) connected from Italy.

At the sunset the sky is clear and conditions are good, we open the dome.

Night duration (12 degree - twilight) 01:45 - 12:30 UT = 10 h 45m
Observing time: 10h 15min (95%)*
Weather time loss: h 6 min (1%)*
Technical time loss: h 24 min (4%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Izzo SN2021ymj LUCI1+2 J H ima 0.05+0.1h luci1.20211016.0001-0014,luci2.20211016.0001-0014 DIMM~1"
Giannini gaia20cwd LUCI1+2 J+H+Ks ima 0.1+0.1+0.1h luci1.0015-0029,luci2.0015-0029 DIMM1.5"
Giannini gaia20cwd LUCI1+2 zJ+HK G200 0.75" 0.5+0.5h luci1.0034-0041,luci2.0034-0041 DIMM1.5-2"
Telluric HD189411 LUCI1+2 zJ+HK G200 0.75"   luci1.0045-0052,luci2.0045-0052 for Giannini
Giannini gaia18dvy LUCI1+2 zJ+HK G200 0.75" 0.5+0.5h luci1.0057-0064,luci2.0057-0064 DIMM1.5-2"
Giannini gaia18dvy LUCI1+2 J+H+Ks ima 0.1+0.1+0.1h luci1.0065-0079,luci2.0065-0079 DIMM ~2-3"
Izzo SN2021zfw LUCI1+2 J H ima 0.05+0.1h luci1.0080-0097,luci2.0080-0097 1.5-2"
Giannini gaia21bkw LUCI1+2 J+H+Ks ima 0.1+0.1+0.1h luci1.0098-0112,luci2.0098-0112 DIMM ~2-3"
Giannini gaia21bkw LUCI1+2 zJ+HK G200 0.75" 0.5+0.5h luci1.0117-00124,luci2.0117-0124 DIMM ~ 5" (GS~2.5")
Telluric HD22859 LUCI1+2 zJ+HK G200 0.75"   luci1.0128-0135,luci2.0128-0135 for Giannini
Telluric BD+493793 LUCI1+2 zJ+HK G200 0.75"   luci1.0139-0146,luci2.0139-0146 for Giannini
Giannini Gaia19bpg LUCI1+2 zJ+HK G200 0.75" 0.19+0.42h luci1.0152-0163,luci2.0152-0163 Saturated emission line in the spectrum. We adjusted the script but this does not help. See log for details. DIMM ~ 2.5-3"
Paiano 4FGLJ0055.7+4507 MODS1+2 dual grating 1.3+1.3h mods1/2b.0002-009 ; mods1/2r.0005-0012 started with seeing=1.7 and improved during the observation down to 1.2". Taken two exposures of 10mins more
Standard G191-B2 MODS1+2 dual grating   mods1/2b.0010-0012 ; mods1/2r.0015-0017 for Paiano
Paiano 4FGLJ0302.5+3354 MODS1+2 dual grating 0.75+0.75h mods1/2b.0013-0015 ; mods1/2r.0021-0023 Seeing ~ 0.8-1" (GS)
Rossi GRB210919A MODS1+2 dual grating 0.5+0.5h mods1/2b.0016-0017 ; mods1/2r.0027-0028 Seeing ~ 0.9" (GS)
Standard GD71 MODS1+2 dual grating 0.15+0.15h mods1/2b.0018-0020 ; mods1/2r.0031-0033 for Rossi