-- SimonaPaiano - 12 Oct 2021

INAF queue observing, 2021 October 11 - October 12

Observer: A. Cardwell
Telescope Operator: J. Williams
Astronomers from Italy: Simona Paiano, Andrea Rossi
Instrument: PEPSI, LUCI

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F. Cusano, A. Rossi, S. Paiano and E. Marini) connected from Italy.

At the sunset the sky seems clear, but the wind is over shutdown limit. For this reason, we remain closed. High wind also at the 12 deg twilight.

Night duration (12 degree - twilight) 01:45 - 12:30 UT = 10 h 45m
Observing time: 0h 0 min ( 0%)*
Weather time loss: 10h 45 min (100%)*
Technical time loss: 0h 0 min (0%)*

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
CALIB Dark-bino LUCI1-2     luci[1,2].20211012.0001-0020 Giannini_12
CALIB Dark-bino LUCI1-2     luci[1,2].20211012.0021-0025 Rossi_18
CALIB Dark-mono LUCI1     luci1.0026-0400 LaBarbera _17
CALIB Dark-mono LUCI1 18NDIT+24NDITx2p51   luci1.0026-0400 probably not necessary Izzo_20
CALIB Dark-bino LUCI1-2 18NDIT+24NDITx2p51   luci1.0051-0060, luci2.0026-0035. Izzo_20
CALIB Dark-mono LUCI1 24x2p51   luci1.0061-0065 probably not necessary Izzo_20
CALIB flats and arcs LUCI1-2 zJ_G200   luci1.0089-0106, luci2.0059-0076 Giannini
CALIB flats LUCI1-2 ima J,H,K   luci1.0107-0136, luci2.0077-0106 Giannini
CALIB flats and arcs LUCI1-2 G210 H,0.5"   luci1.0137-0154 La Barbera
CALIB flats LUCI1-2 ima J   luci1.0155-0164, luci2.0107-0116 Rossi
CALIB flats LUCI1-2 ima J+H   luci1.0170-0184, luci2.0122-0136 Izzo
CALIB Bias MODS1-2     mods[1,2][b,r].20211012.0003-0022 bias for all
CALIB arcs MODS1-2 dualgrating   mods[1,2]r.0023-0025, mods[1,2]b.0023-0025 Paiano , Mannucci, Giannini, Severgnini
CALIB slitflat MODS1-2 dualgrating 0.6"   mods[1,2]r.0026-0031, mods[1,2]b.0026-0031 Mannucci
CALIB slitflat MODS1-2 dualgrating 0.8"   mods[1,2]r.0032-0037, mods[1,2]b.0032-0037 Giannini, Severgnini
CALIB slitflat MODS1-2 dualgrating 1.2"   mods[1,2]r.0044-0049, mods[1,2]b.0044-0049 Paiano
CALIB slitflat MODS1-2 dualgrating 5"   mods[1,2]r.0056-0058, mods[1,2]b.0056-0061 STD
CALIB slitless MODS1-2 dualgrating   mods[1,2]r.0059-0063, mods[1,2]b.0062-0071 Paiano , Mannucci, Giannini, Severgnini
CALIB flat MODS1-2 dual ima r,i   mods[1,2]r.0064-0073  
CALIB arcs+flat MODS1-2 MOS ID 560500   mods[1,2]r.0079-0087 Saracco
CALIB arcs+flat MODS1-2 MOS ID 565554   mods[1,2]r.0088-0096 Saracco
CALIB slitflat MODS1-2 redgrating 5"   mods[1,2]r.0097-00100 Saracco
CALIB slitless MODS1-2 redgrating   mods1r.0105-00109, mods2r.0103-00107 Saracco
CALIB flat MODS1-2 red ima r,i   mods[1,2]r.0108-0119 Paiano
CALIB arcs+flat MODS1-2 mos_503108   mods[1,2]b.0082-090, Mods[1,2]r.0120-0128 Biazzo
CALIB arcs+flat MODS1-2 mos_503312   mods[1,2]b.0091-099, mods[1,2]r.0129-0137 Biazzo
CALIB arcs+flat MODS1-2 mos_503450   mods[1,2]b.0100-108, mods[1,2]r.0138-0146 Biazzo
             
Detailed log by A. Cardwell at this link:

https://drive.google.com/file/d/1hMQMMptQQ4wpcQ3Ybge2vSBFE8o0oh7j/view?usp=sharing

Other note

Topic revision: r11 - 13 Oct 2021, SimonaPaiano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.