INAF queue observing, 2021 June 5 - June 6

Observer: D. Thompson
Telescope Operator: J. Williams
Astronomers from Italy: Felice Cusano, Simona Paiano and Andrea Rossi
Instrument: LUCI

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (F. Cusano, A. Rossi and S. Paiano) connected from Italy.

At the sunset the sky is covered by clear, wind at the limit, but we can open.
After 20 minutes from the opening we close for high fraction of 25 micron particles detected in the air. There is a big wild fire 24 mph from the telescope.
We open again at 3:47 UT. Very bad seeing at the beginning of the nigth

Night duration (12 degree - twilight) 04:25 - 11:10 UT = 6 h 45m
Observing time: * 4h 50min (72%)*
Weather time loss: * 1h 30min (22%)*
technical time loss: 0 h 25 min (6%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calibrations darks LUCI BINO       for Epifani and Cassara' C4
Rossi_18 GRB210312B LUCI BINO Ks+J,H     dimm seeing ~2"
Palazzi_strategic GRB210410A LUCI BINO Ks+H     dimm seeing ~2-3"
Massi G049 LUCI BINO H2+Ks     completed
STD FS144 LUCI BINO H2+Ks     for Massi
telluric HD 228448 LUCI BINO zJ+HK200+K210     for Antoniucci V1057
Antoniucci V1057Cyg LUCI BINO zJ+HK200+K210      
telluric HD 160233 LUCI BINO zJ+HK200     for Antoniucci AGLL999
Antoniucci AGLL999 LUCI BINO zJ200 only      
Calibrations flat arcs LUCI BINO zJ+HK200+K210 0.75"     for Antoniucci
Detailed log by D. Thompson at this link: https://drive.google.com/file/d/1_qknfO9vIJtwolMadEG2cglLuPoZ2wiy/view?usp=sharing