-- AndreaRossi - 11 Mar 2021

INAF queue observing, 2021 Mar 10 - Mar 11

Observer: J. Power
Telescope Operator: J. Williams
Astronomers from Italy: A. Rossi, F. Cusano
Instrument: LBC

Summary

Due to the covid-19 pandemic situation these observations have been performed by LBTO personel
through the indications of LBT Italian observers (A. Rossi and F. Cusano) connected from Italy.

At the sunset the sky is clear, we start with LBC.

Night duration (12 degree el twilight) 02:20 - 12:40 UT = 10 h 20m
Observing time: 8h 25min (80%)
Weather time loss: 1h 45min (18%)
technical time loss 0h 10min (2%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calibration darks         for Annibali AO, Saracco, Antoniucci: 120s,50s,30s 300s (good for Polletta too)
Nonino COSMOS LBCb+LBCr 0.5h+0.5h OB8 bad seeing
Rossi GRB 210306A LBCb+LBCr r+z 0.3h+0.3h    
Schmidt J0823+3427 LBCb+LBCr r+z 0.25h+0.25h   OB4 seeing ~1.1"
Rossi GRB 190530A LBCb+LBCr r+z 0.3h+0.3h    
Nonino EGS LBCb+LBCr 0.5h+0.5h OB 7 bad seeing
Vito J164121+375520 LBCb+LBCr r+z 10m   seeing ~1.5"
telluric AOV 55182 LUCI bino HKspec     for Polletta
Polletta PLCK_G124 LUCI bino MOS HKspec 1.33h+1.33h   seeing >1.5"
Calibration arc+flats LUCI bino MOS HKspec,200     for Polletta
Calibration arc+flats LUCI bino zJ-HKspec,200     for Antoniucci
Calibration flats LUCI bino J ima N375     for Antoniucci
Calibration flats LUCI1 J,H ima N30     for Annibali
Detailed log of the nigh by J. Power at this link: https://drive.google.com/file/d/15K0a2DDskyMnLHCKQeEZpdcFfYtstcTK/view?usp=sharing
Topic revision: r5 - 13 Mar 2021, FeliceCusano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback