INAF queue observing, 2020 Jan 31 - Feb 01

Observers: A. Rossi, S. Paiano & Telescope Operator: S. Allanson & Support Astronomer: D. Thompson & Instrument: MODS1-2

At sunset the sky is partly cloudy and windy

MODS: both ok

LBC:
  • LBC Red ok; LBC blue is available although is just following the guiding of LBCred.

LUCI:
  • LUCI1: not available all week
  • LUCI2: not mounted

Temperature = -1 Humidity = 15 Wind guts >15

Summary

Night duration (12 degree - twilight) 1:30 - 13:30 UT = 12h 00m = 43200 seconds
Observing time: 12h min (100%)

Weather time loss min (0%) sec

Technical time loss: min (0%) sec

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calibration flat MODS1-2 dual slitflat 0.6"     per Mannucci
Calibration flat MODS1-2 dual slitflat 0.8"     per Antoniucci - to check the quality of the frames

Antoniucci V1118Ori MODS1-2 dual grating 0.8" 20 mins mods1b.0022-25 ,mods1r.0026-29 - mods2b.0022-25, mods2r.0026-29 completed
Antoniucci AGLL192 MODS1-2 dual grating 0.8" 20 mins mods1b.0026-29 ,mods1r.0033-36 - mods2b.0026-29, mods2r.0034-37 completed
Antoniucci AGLL96 MODS1-2 dual grating 0.8" 20 mins mods1b.0030-33 ,mods1r.0040-43 - mods2b.0030-33, mods2r.0041-44 completed
Antoniucci AGLL129 MODS1-2 dual grating 0.8" 20 mins mods1b.0034-37 ,mods1r.0049-52 - mods2b.0034-37, mods2r.0049-52 completed
Mannucci J104524+4144 MODS1-2 dual grating 0.6"   mods1b.0038-39 43-44 ,mods1r.0056-57 66-67 - mods2b.0038-39 43-44, mods2r.0056-57 68-69 completed
STD GD191 MODS1-2 dual grating 5"   mods1b.0040-42 ,mods1r.0060-62 - mods2b.0040-42, mods2r.0062-64  
Antoniucci FuOri MODS1-2 dual grating 0.8" 16 mins mods1b.0045-48, mods1r.0071-74 - mods2b.0045-48, mods2r.0073-76 completed
Mannucci J111501-1242 MODS1-2 dual grating 0.6"     completed
Mannucci J130646+1522 MODS1-2 dual grating 0.6"     completed
Mannucci J151338+5739 MODS1-2 dual grating 0.6"     4 times completed

Details

CALIBRATION MODS

01:41 We start with Antoniucci's program pointing V1118Ori with MODS1-2.
  • Seeing 1.2" - Weather is fine, except for the wind around 14 m/s.
  • Acq mods1r.2020201.0023-0024-25, mods2r.0023-0024-25 No problems during the acquisition
  • Sci mods1b.0022-25 ,mods1r.0026-29 - mods2b.0022-25, mods2r.0026-29

02:32 We continue with Antoniucci's program pointing AGLL192 with MODS1-2.
  • Seeing 1.25" - Weather is fine, except for the wind around 16 m/s.
  • Acq mods1r.20200201.0030-32 mods2r.0030-33 No problems during the acquisition
  • Sci mods1b.0026-29 ,mods1r.0033-36 - mods2b.0026-29, mods2r.0034-37

03:20 We continue with Antoniucci's program pointing AGLL96 with MODS1-2.
  • Seeing 1.4" - Weather is fine, wind trend is decreasing (now ~14 m/s).
  • Acq mods1r.20200201.0037-39 mods2r.0038-40 No problems during the acquisition
  • Sci mods1b.0030-33 ,mods1r.0040-43 - mods2b.0030-33, mods2r.0041-44

04:04 Antoniucci's program pointing AGLL129 with MODS1-2.
  • Seeing 2.3" - Some clouds and we are close to the moon. Wind is 17 m/s
  • Acq mods1r.20200201.0044-48 mods2r.0045-48 Seeing variable during the acquisition
  • Seeing = 1.5" on DIMM
  • Sci mods1b.0034-37 ,mods1r.0049-52 - mods2b.0034-37, mods2r.0049-52

04:50 We change source and we are pointing J104524+4144 of the Mannucci's program .
  • Seeing 1.1-1.3" on DIMM
  • Acq mods1r.20200201.0053-55 mods2r.0053-55
  • Sci mods1b.0038-39 ,mods1r.0056-57 - mods2b.0038-39, mods2r.0056-57

5:25 We are taking a Standard star spectrum (GD191).
  • Seeing 1.15" on DIMM
  • Acq mods1r.20200201.0058-59 mods2r.0058-60
  • Sci mods1b.0040-42 ,mods1r.0060-62 - mods2b.0040-42, mods2r.0062-64

05:55 We again point J104524+4144 of the Mannucci's program .
  • Seeing 1.1-1.3" on DIMM
  • Acq mods1r.20200201.0063-65 mods2r.0065-67
  • Seeing highly variable up to 2.0"
  • Sci mods1b.0043-44, mods1r.0066-67 - mods2b.0043-44, mods2r.0068-69

06:32 We move to the Antoniucci program and we observe the FuOri source
  • Acq mods1r.20200201.0068-70 mods2r.0070-72
  • Seeing up to 2.5" on DIMM
  • Sci =mods1b.0045-48, mods1r.0071-74 - mods2b.0045-48, mods2r.0073-76 =

07:09 We observe J1115-1242 of Mannucci PA=-20
  • Seeing 1.9" on DIMM
  • Acq mods1r.20200201.0075-78 mods2r.0077-80
  • Seeing 1.3"-1.9" on DIMM
  • Sci mods1b.0049-50, mods1r.0079-80 - mods2b.0049-50, mods2r.0081-82

07:59 We observe J130646+15 of Mannucci PA=120
  • Seeing 1.4" on DIMM
  • Acq mods1r.20200201.0081-83 mods2r.0083-85
  • Seeing 1.4"-2.0" on DIMM
  • Sci =mods1b.0051-52, mods1r.0084-85- - mods2b.0051-52, mods2r.0086-87 =

08:34 We observe J1115-1242 of Mannucci PA=-20
  • Seeing 1.7" on DIMM
  • Acq mods1r.20200201.0086-88 mods2r.0088-90
  • Seeing 1.4"-1.7" on DIMM
  • Sci =mods1b.0053, mods1r.0089 - mods2b.0053, mods2r.0091 =

08:59 We observe J1513+57 of Mannucci PA=270
  • Seeing 1.7" on DIMM
  • Acq mods1r.20200201.0090-92 mods2r.0092-94
  • Seeing 1.6" on DIMM
  • Sci =mods1b.0054-55, mods1r.0093-94 - mods2b.0054-55, mods2r.0095-96 =

09:32 We observe J130646+15 of Mannucci PA=120
  • Seeing 1.9 on DIMM
  • Acq mods1r.20200201.0095-97 mods2r.0097-99
  • Seeing 1.3 on DIMM
  • Sci =mods1b.0056-57, mods1r.0098-99 - mods2b.0056-57, mods2r.0100-0101 =

10:08 We observe J1115-1242 of Mannucci PA=10
  • Seeing 1.7" on DIMM
  • Acq mods1r.20200201.0100-0103 mods2r.0102-104
  • Sci =mods1b.0058, mods1r.0103 - mods2b.0058, mods2r.0105 =

10:36 We observe J1513+57 of Mannucci PA=245
  • Seeing 2.1" on DIMM
  • Acq mods1r.20200201.0104-107 mods2r.0106-0109 The acq image of mods1b is strange but usable
  • Seeing 1.9" on DIMM
  • Sci =mods1b.0059-0060, mods1r.0108-0109 - mods2b.0059-0060, mods2r.0110-0111 =

11:13 We observe J1115-1242 of Mannucci PA=30
  • Seeing 1.8" on DIMM
  • Acq mods1r.20200201.0110-0113 mods2r.0112-114
  • Seeing 1.4" on DIMM
  • Sci =mods1b.0061-0062, mods1r.0114-0115 - mods2b.0061-0062, mods2r.0115-0116 =

11:47 We observe J1513+57 of Mannucci PA=245
  • Seeing 1.3" on DIMM
  • Acq mods1r.202001.0116-0119 mods2r.0117-0119 The acq image of mods1b is strange but usable
  • Seeing 1.2" on DIMM
  • Sci =mods1b.0063, mods1r.0120 - mods2b.0063, mods2r.0120 =

12:32 We observe J130646+15 of Mannucci PA=60
  • (lost 20 min because we lost guiding and had to change guide star - poor guide star selection)
  • Seeing 1.3" on DIMM
  • Acq mods1r.202001.0123-0125 mods2r.0123-0125
  • Sci =mods1b.0064, mods1r.0126 - mods2b.0064, mods2r.0126 =

12:54 We observe J1513+57 of Mannucci PA=205
  • Acq mods1r.202001.0127-0129 mods2r.0127-0129
  • Seeing 1.0" on DIMM
  • Sci =mods1b.0065, mods1r.0130 - mods2b.0065, mods2r.0130 =

13:18 We observe J130646+15 of Mannucci PA=60
  • Acq mods1r.202001.0131-0 mods2r.0131-0
  • Seeing 1.2" on DIMM

FIN
Topic revision: r7 - 07 Feb 2020, AndreaRossi