INAF queue observing, 2019 Dec 1 - Dec 2

Observer: F. Cusano, A. Gargiulo
Telescope Operator: S. Allanson
Support Astronomer: B. Rothberg (on call)
Instrument:

At the sunset the sky is clear.

Summary

Night duration (12 degree el twilight) 1:20 - 12:50 UT = 11 h 30m

Observing time: 11h 30min (100%)

Weather time loss: h min (0%)

technical time loss 0min (0%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calibration Di Criscienzo Dark LUCI1-2        
Calibration Di Criscienzo sky-flat LUCI1-2 J/Ks      
Di Criscienzo Peg_1, _2, _3, _4, _5, _6, _7, _8, _9, _10, _11, _12 LUCI1-2 J/Ks 0.15h each    
Gargiulo HIP10185 LUCI1-2 G200/zJ      
Gargiulo VAN003 LUCI1-2 G200/zJ 6/10h luci.0119-0154 luci2.0119-0154  
Belladitta HIP16652 LUCI1-2 G200/zJ      
Belladitta PSOJ03 LUCI1-2 G200/zJ 3/3h luci1.0166-0183 luci2.0166-0183 completed
Antoniucci HIP33723 LUCI1-2 G200/zJ-HK      
Antoniucci iPTF15afq LUCI1-2 G200/zJ 0.11/0.11h luci1.0196-0197 luci2.0196-0197 completed
Antoniucci iPTF15afq LUCI1-2 G200/HK 3.66/3.66m luci1.0198-0199 luci2.0198-0199 completed
Epifani RU152B LBC B-R U/B - V/R/I      
Epifani SA100 LBC B-R U/B - V/R/I      
Epifani Borisov LBC B-R U/B - V/R/I      
Calibration Epifani skyfalt LBC B-R B - I      

Details

Calibrations
  • Di Criscienzo darks luci1.20191202.001-010 luci2.20191202.001-010
  • Di Criscienzo J/Ks skyflat luci1.011-033 luci2.011-033

00:57 we slew to Di Criscienzo target
  • 00:58 we send Peg_1 script
  • 01:00 seeing on dimm 1.0"
  • 01:09 we send Peg_2 script
  • 01:21 we send Peg_3 script
  • 01:22 seeing on dimm 1.1"
  • 01:32 we send Peg_4 script
  • 01:41 seeing on dimm 0.9"
  • 01:45 we send Peg_5 script
  • 01:53 seein on dimm 0.9"
  • 01:54 we send Peg_6 script
  • 02:05 seeing on dimm 0.9"
  • 02:05 we send Peg_7 script
  • 02:16 seeing on dimm 0.9"
  • 02:16 we send Peg_8 script
  • 02:27 seeing on dimm 0.9"
  • 02:27 we send Peg_9 script
  • 02:38 seeing on dimm 1.0"
  • 02:40 we send Peg_10 script
  • 02:49 seeing on dimm 0.9"
  • 02:49 we send Peg_11 script
  • 03:00 seeing on dimm 1.1"
  • 03:00 we send Peg_12 script
  • 03:09 we lost guide star

3:13 we slew to Gargiulo target
  • 03:13 we send the HIP10185 script
  • 03:15 seeing on dimm 0.9"
  • acq luci1.0105-0107 luci2.0105-0107
  • sci luci1.0108-0109 luci2.0108-0109
  • acq luci1.0110-0112 luci2.0110-0112
  • sci luci1.0113-0114 luci2.0113-0114

  • 03:33 we send VAN003 script
  • 03:36 seeing on dimm 0.8"
  • acq luci1.0115-0118= ==luci2.0115-0118
  • 03:49 seeing on dimm 0.8"
  • 04:23 seeing on dimm 0.7"
  • 05:13 seeing on dimm 0.7"
  • 06:00 seeing jumps to 1.2"
  • 06:13 seeing on dimm 0.7"
  • 06:51 seeing on dimm 1.1"
  • 07:02 seeing on dimm 1.1"
  • sci luci1.0119-0154 luci2.0119-0154

07:08 we slew to Belladitta DDT
  • 07:09 we send HIP16652 script
  • 07:12 seeing on dimm 1.2"
  • acq luci1.0155-0157 luci2.0155-0157
  • sci luci1.0158-0161 luci2.0158-0161

  • 07:20 we send PSOJ030 script
  • 07:23 copointing check
  • 07:23 seeing on dimm 1.23"
  • 07:30 we send the script againg
  • acq luci1.0162-0165 luci2.0162-0165
  • 07:40 seeing on dimm 1.1"
  • 07:57 seeing on dimm 1.3"
  • 08:45 seeing on dimm 0.9"
  • 09:19 seeing on dimm 0.9"
  • sci luci1.0166-0183 luci2.0166-0183

09:21 we slew to Antoniucci target
  • 09:22 we send HIP33723 script
  • acq luci1.0184-0186 luci2.0184-0186
  • 09:29 seeing on dimm 0.8"
  • 09:30 science and acquisition have two different slits. This causes some delay (5 minutes) in starting the integration.
  • sci (zJ) luci1.0187-0189 luci2.0187-0189
  • sci (HK) luci1.0190-0192 luci2.0190-0192

  • 09:39 we slew to iPTF15afq target
  • 09:40 seeing 0.8"
  • acq luci1.0193-00195 luci2.0193-0195
  • sci (zJ) luci1.0196-0197 luci2.0196-0197
  • 09:59 seeing on dimm 0.7"
  • sci (HK) luci1.0198-0199 luci2.0198-0199

10:00 we move to LBC

10:20 we send RU152 co-pointing
  • 10:26 some problems with the primary mirror
  • 10:26 we send the co-pointing again
  • 10:28 we send the co-pointing again
  • 10:29 dohybrid
  • 10:41 we send RU152B script
  • 10:44 seeing on dimm 0.75"
lbcr.20191202.124846.fits SA100-267 1.238 2019-12-02T12:48:46.941 I-BESSEL

10:50 we send SA100
  • 11:10 dophia
  • 11:10 seeing on dimm 0.7"
  • 11:19 dophia

11:28 we send the Borisov script
  • 11:36 seeing on dimm 0.78"
  • 11:57 dophia
  • 12:00 seeing on dimm 0.9"
  • 12:04 we send the script again

12:36 we send the RU152 script

12:44 we send the SA100 script

12:55 we send the RU152 script

Calibrations
  • Epifani skyflat B - I
Topic revision: r9 - 29 Jun 2020, FeliceCusano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback