INAF queue observing, 2019 Oct 21- Oct 22

Observer: A. Rossi + R. Carini+ and M. Faccini from Rome
Telescope Operator: S. Allanson
Support Astronomer: D. Thompson
Instrument: LBC

At the sunset the sky is clear. LUCI2 is not available for spectroscopy due to masks-related problems.

Summary

Night duration (12 degree el twilight) 1:40 - 12:30 UT = 10 h 50m

Observing time: 10h * 50min* (100%)

Weather time loss: 0h 0min (0%)

technical time loss 0h 0min (0%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Garofalo Pegasus III LBC B, V 0.4h+0.4h   completed
Garofalo Pisces II LBC B, V 0.4h+0.4h   completed
Schmidt J2358+0125 LBC LBCb g, LBCr i, r i=0.30h r=0.13h g=0.47H   completed
Mannucci J011302 MODS1+MODS2 dual grating (0.33h + 0.33h)/0.84h mods1r.0005, 0017, 0031, 0045; mods1b.0002, 0005, 0008, 0011; mods2r.0005, 0017, 0029, 0041; mods2b.0002, 0005, 0008, 0011 only 4 spectra
Mannucci J034319 MODS1+MODS2 dual grating (0.42+0.42)h/0.84h mods1r.0009, 0022, 0035, 0052, 0061; mods1b.0003, 0006, 0009, 0012, 0014; mods2r.0009, 0021, 0033, 0047, 0055; mods2b.0003, 0006, 0009, 0012, 0014 completed
Mannucci J033205 MODS1+MODS2 dual grating (0.42+0.42)h/0.84h mods1r.0013, 0027, 0039, 0056, 0065; mods1b.0004, 0007, 0010, 0013, 0015; mods2r.0013, 0025, 0037, 0051, 0061; mods2b.0004, 0007, 0010, 0013, 0015 completed
ROSSI DDT Sn2018ibb MODS1+MODS2 dual grating +ima(ug+riz) (0.42+0.42)h/1.0h + 4m/4m mods1r.0070-0071, mods1b.0016-0017; mods2r.0066-0067,mods2b.0016-0017; mods1r.0072-0073, mods1b.0018-0019; mods2r.0068-0069,mods2b.0018-0019  
Belladitta PSOJ0944 MODS1+MODS2 red grating (0.22+0.22)h/2.6 h mods1r.0078, mods2r.0073  
Standard GD71 MODS1+2   mods1r.0082-0085; mods1b.0020-0021 mods2r.0077-0080; mods2b.0020-0021 for RossiDDT e Belladitta
sky flat   LBCb LBCr r,i    

LUCI Calibrations
  • LUCI darks 5sx12 lir int luci.20191022.0002-0006
  • LUCI darks 60.0x1 lir norm luci.20191022.00-0011
  • LUCI darks 30.0x2 lir int luci.20191022.0012-0016

LBC skyflats
  • LBCb Uspec PA 180 0 , LBCR V PA 180 0 are ok
  • LBCb g 180 0 , LBCR R PA 180 0 are ok
  • LBCR r PA 180 0 are ok

01:33 Slew to Garofalo Pegasus III
  • dohybrid
  • copointing
  • 01:48 blue not perfect dofpia again
  • 01:50 start Pegasus_1
  • seeing 1.1" on DIMM at 01:51
  • 01:55 start Pegasus_2
  • seeing 1.2 on image
  • 02:01 start Pegasus_3, DIMM 1.2"
  • 02:07 start Pegasus_4, DIMM 1.1", 1.1" on image
  • dofpia at 02:13
  • 02:17 start Pegasus_5, DIMM jump 1.5" !!! actually in the image I found later seeing 1.2" so ok
  • 02:21 DIMM 1" take again, seeing 1" on image
  • 02:26 start Pegasus_6, DIMM 1.2"
  • 02:33 start Pegasus_7, DIMM 1.2", seeing 1" on image
  • 02:39 start Pegasus_8, DIMM 1.3"

02:46 Slew to Garofalo Pisces II
  • dofpia
  • 02:51 Pisces_1, DIMM 1.1"
  • 02:57 Pisces_2, DIMM 1.1"
  • DIMM jump to 2" take again 0.9" on image
  • 03:08 Pisces_3, DIMM 1.2"
  • 03:13 Pisces_4 seeing 1.1" on image
  • dofpia
  • 03:23 Pisces_5
  • 03:28 Pisces_6
  • 03:33 Pisces_7 0.8" on image
  • 03:39 Pisces_8 DIMM 1"

03:44 Slew to Schmidt Program, J2358+0125
  • dofpia
  • copointing
  • 03:55 J2358+0125_g_i_1 seeing 0.7" on image image 035737 on LBCR not good readout problem?
  • dofpia
  • 04:15 J2358+0125_g_i_1 again DIMM 0.7" seeing 0.6" on image
  • 04:30 J2358+0125_g_i_2 last image elongated in LBCb. stop. We have enough g+i exposures
  • DIMM 1"
  • 04:40 dofpia
  • 04:47 J2358+0125_g_r seeing 0.9" on image

05:02 Switch to MODS

05:23 Slew to Mannucci's program, target J011302, PA=-20 degree
  • acq mods1r.0002.fits-mods1r.0004.fits; mods2r.0002.fits-mods2r.0004.fits
  • 05:35 sci mods1r.0005, mods1b.0002; mods2r.0005, mods2b.0002
  • dimm variable up to 1.5"

05:44 target J034319, PA=-45 degree * acq mods1r.0006-0008; mods2r.0006-0008 * sci mods1r.0009, mods1b.0003; mods2r.0009,mods2b.0003

06:09 target J033205 PA=-30 degree
  • acq mods1r.0010-0012; mods2r.0010-0012
  • 06:19 sci mods1r.0013, mods1b.0004; mods2r.0013,mods2b.0004
  • dimm 1.0"

06:28 target J011302, PA=0 degree
  • acq mods1r.0014-0016; mods2r.0014-0016
  • sci mods1r.0017, mods1b.0005; mods2r.0017,mods2b.0005
  • dimm 1.3"

06:53 target J034319, PA=-45 degree
  • acq mods1r.0018-0021; mods2r.0018-0020
  • 07:06 sci mods1r.0022, mods1b.0006; mods2r.0021,mods2b.0006
  • dimm 0.6"

07:15 target J033205 PA=-30 degree
  • acq mods1r.0023-0026; mods2r.0022-0024
  • 07:30 sci mods1r.0027, mods1b.0007; mods2r.0025,mods2b.0007
  • dimm 0.7"

07:40 target J011302, PA=0 degree
  • acq mods1r.0028-0030; mods2r.0026-0028
  • 07:54 sci mods1r.0031, mods1b.0008; mods2r.0029,mods2b.0008
  • dimm 0.6"

08:03 target J034319, PA=0 degree
  • acq mods1r.0032-0034; mods2r.0030-0032
  • 08:15 sci mods1r.0035, mods1b.0009; mods2r.0033,mods2b.0009
  • dimm 0.9"

8:24 target J033205 PA=0 degree
  • acq mods1r.0036-0038; mods2r.0034-0036
  • 08:35 sci mods1r.0039, mods1b.0010; mods2r.0037,mods2b.0010
  • dimm 0.9"

08:42 target J011302, PA=30 degree
  • acq mods1r.0040-0044; mods2r.0038-0040
  • 8:56 sci mods1r.0045, mods1b.0011; mods2r.0041,mods2b.0011
  • dimm 0.8"

09:06 target J034319, PA=0 degree
  • acq mods1r.0046-0047; mods2r.0042-0043
  • 09:09 problem with MODS2 guide, we stop the integration with MODS2
  • 09:14 start again the acquisition in both MODS mods1r.0048-0051; mods2r.0044-0046
  • 09:23 sci mods1r.0052, mods1b.0012; mods2r.0047,mods2b.0012
  • dimm 0.9"

09:35 target J033205 PA=30 degree
  • acq mods1r.0053-0055; mods2r.0048-0050
  • 09:46 sci mods1r.0056, mods1b.0013; mods2r.0051,mods2b.0013
  • dimm 0.8"

09:56 target J034319, PA=45 degree
  • acq mods1r.0057-0060; mods2r.0052-0056
  • 10:08 sci mods1r.0061, mods1b.0014; mods2r.0057,mods2b.0014
  • dimm 0.8"

10:20 target J033205 PA=30 degree
  • acq mods1r.0062-0064; mods2r.0058-0060
  • 09:46 sci mods1r.0065, mods1b.0015; mods2r.0061,mods2b.0015
  • dimm 0.8"

10:37 slew to Rossi's DDT
  • acq mods1r.0066-0069; mods2r.0062-0065 airmass 1.7, PA=10
  • 10:51 sci mods1r.0070-0071, mods1b.0016-0017; mods2r.0066-0067,mods2b.0016-0017
  • dimm 0.8"

11:24 imaging sci mods1r.0072-0073, mods1b.0018-0019; mods2r.0068-0069,mods2b.0018-0019

11:35 slew to Belladitta's program PSOJ0944
  • acq mods1r.0074-0077; mods2r.0070-0072
  • 11:47 sci mods1r.0078-0079, mods2r.0073-0074 the last images (mods1r.0079 mods2r.0074 are long only 2 minuts)
  • dimm 0.6"

12:10 slew to standard star, GD71
  • acq mods1r.0080-0081 mods2r.0075-0076
  • 12:17 dual + red grating sci mods1r.0082-0085; mods1b.0020-0021 mods2r.0077-0080; mods2b.0020-0021

12:37 switch to LBC to do some sky flats
  • LBCb r; LBCr i
Topic revision: r5 - 25 Oct 2019, AndreaRossi
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback