INAF queue observing, 2019 Oct 20- Oct 21

Observer: A. Rossi + R. Carini+ and M. Faccini from Rome
Telescope Operator: S. Allanson
Support Astronomer: D. Thompson
Instrument: MODS

At the sunset the sky is clear. LBTO staff working on a leak in the chiller before sunset. LUCI2 is not available for spectroscopy due to masks-related problems.

Summary

Night duration (12 degree el twilight) 1:40 - 12:30 UT = 10 h 50m

Observing time: 10h 35 min (98%)

Weather time loss: 0h min (0%)

technical time loss 0h 15min (2%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Mannucci J165923 MODS1+2 dualgrating 10m mods1r.0005,mods1b.0002 mods2r.20191020.0061,mods2b.20191021.0002 note the mods2r not updated name
Garofalo Pegasus III MODS1+2 dualgrating 40m/2h mods1r.0009-0010,mods1b.20191021.0003-0004 mods2r.20191021.0004-0005,mods2b.20191021.0003-0004 I forgot to do -y 25 in mods Align but can see spectra of target
Mannucci J165923 MODS1+2 dualgrating 10m mods1r.0014,mods1b.0005 mods2r.0009,mods2b.0005  
Garofalo Pegasus III MODS1+2 dualgrating 20m/2h mods1r.0019,mods1b.0006 mods2r.0013,mods2b.0006 seeing is better during this exposure! and I did modsAlign -y 25 !
Mannucci J165923 MODS1+2 dualgrating 10m mods1r.0024,mods1b.0007 mods2r.0018,mods2b.0007 completed
Garofalo Pegasus III MODS1+2 dualgrating 20m/2h mods1r.0029,mods1b.0008 mods2r.0022,mods2b.0008 seeing is better during this exposure! and I did modsAlign -y 25 ! completed
Cassarà VIPB1 LUCI1 zJ mos 0.66/2h luci1.0009-0020 luci1.0032-0035 seeing jumps above 1.5" check
Telluric HIP13917 LUCI1 zJ     for Cassarà VIPB1
Telluric HIP16652 LUCI1 zj, HK     Antoniucci AGL31
Antoniucci AGL31 LUCI1 zj , HKK 0.8/0.8h luci1.0051-0062 completed
Telluric HIP24342 LUCI1 zj Hk   luci1.0066-0073  
Antoniucci V1118 Ori LUCI1 zj 0.4 luci1.0078-0081  
Telluric HD46106 LUCI1 K   luci1.0086-0089 for Giannini
Giannini IRAS06297 LUCI1 K 0.5/0.5 h luci1.0094-0123 completed
Giannini V912 Mon LUCI1 K 0.5/0.5h luci1.0128-0157 completed
Telluric HD46106 LUCI1 K   luci1.0162-0165 for Giannini
Giannini V899 Mon LUCI1 K 0.5/0.5 h luci1.0170-0199 completed
Sky flat blue: B; red: I, V (angle=0)   LBC        

Details

01:26 Slew to Mannucci J165923 PA-70
  • acq mods1r.20191021.0002-0004== mods2r.20191020.0058-60 MODS setup updated only blue and not red date!
  • 01:35 seeing 1" on DIMM and guiding
  • 01:36 sci mods1r.0005,mods1b.0002 mods2r.20191020.0061,mods2b.20191021.0002 note the mods2r not updated name!!

01:47 Slew to Garofalo longslit Pegasus III
  • 01:51 seeing
  • acq mods1r.20191021.0006-0008== mods2r.20191021.0001-03
  • 02:00 seeing 1.1" on DIMM
  • 01:59 sci mods1r.0009-0010,mods1b.20191021.0003-0004 mods2r.20191021.0004-0005,mods2b.20191021.0003-0004
  • 02:03 seeing 1.5" on DIMM 1.3 on guider!
  • 02:06 DIIM down to 1.3", 1.2" on guider
  • 02:16 DIIM down to 1.2", 1.0" on guider
  • IMPORTANT: I forgot to do -y 25 in mods Align, just the usal modsALign -y 11 and -y 9 . But we can see the spectra very well in both MODS, b and r!

01:26 Slew to Mannucci J165923 PA-70
  • acq mods1r.0011-0013== mods2r.0006-0008
  • seeing 1.4" on guider
  • sci mods1r.0014,mods1b.0005 mods2r.0009,mods2b.0005

02:48 Slew to Garofalo longslit Pegasus III
  • 02:50 seeing 1.2" on DIMM , 1" on guider
  • seeing is better during this exposure! and I did modsAlign -y 25 !
  • acq mods1r.0015-0018== mods2r.0010-0013 adjusted offset manually
  • 03:03 sci mods1r.0019,mods1b.0006 mods2r.0013,mods2b.0006
  • 03:05 seeing 1.2" on DIMM , 1" on guider

03:20 Slew to Mannucci J165923 PA-100
  • acq mods1r.0020-0023== mods2r.0014-0017 adjusted offset manually
  • 03:37 sci mods1r.0024,mods1b.0007 mods2r.0018,mods2b.0007
  • seeing 0.9" on DIMM, 1.5" on guider

03:46 Slew to Garofalo longslit Pegasus III
  • acq mods1r.0025-0028== mods2r.0019-0021 adjusted offset manually
  • seeing 1.2" on DIMM, 1.0" on guider
  • sci mods1r.0029,mods1b.0008 mods2r.0022,mods2b.0008
  • 04:07 seeing 1.1" on DIMM, 0.9" on guider

04:16 Switch to LUCI

04:35 Seeing 1.2 on DIMM, Slew to Cassarà VIPB1
  • had to do AFC correction, start again, 5min loss
  • acq luci1.0005-0008 wonderfull allignement nothing to correct, congratulations to Letizia and Jenny for new MOS allignement software
  • DIMM 1.3" at 05:04 UT
  • sci luci1.0009-0020 wonderfull allignement nothing to correct, congratulations to Letizia and Jenny for new MOS allignement software
  • I can see the spectra in the top and bottom science slits after subtracting the first 2 exposures smile
  • NOTE: the guiding star is not 12.5, it is more likely 15 mag. the bright R band in catalog is probably due to Halpha. Better to use another guiding star
  • 05:10-05:20 seeing up to 2"
  • 05:23 DIMM 1.3"
  • 05:30 seeing up to 1.5"
  • 05:45 DIMM seeing to 2" stop integration after 40min of exposure time (12x200s)

04:46 Stop and go to telluric field HIP13917
  • acq luci1.0021-0023
  • sci luci1.0024-0028
  • 05:58 DIMM 2"

06:03 seeing down to 1" Slew to Cassarà VIPB1
  • acq luci1.0029-0031
  • sci luci1.0032-0035
  • DIMM 1.1", 1.1" on guider
  • 06:20 seeing variable up to 2"

06:32 seeing is to high, we slew to Antoniucci's program, telluric for AGL31, HIP16652
  • acq luci1.0036-0038
  • sci luci1.0039-0046
  • dimm 1.6"

06:52 target AGl31
  • acq luci1.0047-0050
  • sci luci1.0051-0062
  • dimm 2.4"
  • 07:27 dimm 1.7"
  • 07:45 dimm 1.3"
  • 08:04 dimm 1.5"

08:10 telluric HIP24342 for the target V1118 Ori
  • acq luci1.0063-0065
  • sci luci1.0066-0073
  • dimm 2.00"

08:26 target V1118 Ori
  • acq luci1.0074-0077
  • sci luci1.0078-0081
  • dimm variable up to 1.6"

08:53 slew to Giannini's program, telluric HD46106
  • acq luci1.0082-0085, dimm 1.4"
  • sci luci1.0086-0089

09:15 target IRAS06297
  • acq luci1.0090-0093 the guide star probably is a double star, for now it is ok, but we could have some problems
  • dimm 1.6"
  • sci luci1.0094-0123
  • 09:37 dimm 1.5"
  • 09:48 dimm 1.2"
  • 10:00 dimm 1.1"

10:12 target V912 Mon
  • acq luci1.0124-0127 dimm 1.0"
  • 10:18 rtd subtruction very slow
  • 10:27 sci luci1.0128-0157
  • 10:36 dimm 1.0"-1.1"
  • 10:53 dimm 1,0"-1.1"
  • 11:08 dimm 1.1"-1.2"

11:14 telluric HD46106
  • acq luci1.0158-0161
  • sci luci1.0162-0165
  • dimm 1.2"-1.5"

11:30 target V899 Mon
  • acq luci1.0166-0169
  • sci luci1.0170-0199
  • 11:34 dimm 1.3"
  • 11:58 dimm 1.0"
  • 12:13 dimm 1.3-1.4"

12:30 switch to LBC to do sky flat

12:50 sky flat, B and I, U spec and V
  • 12:03 error in LBC blue
  • 12:07 error in blue channel : one or more systems failed
  • 12:13 start again the sky flat