-- AndreaRossi - 18 Oct 2019

INAF queue observing, 2019 Oct 18- Oct 19

Observer: A. Rossi + M. Faccini and A. Giunta from Rome
Telescope Operator: S. Allanson
Support Astronomer: B. Rothberg
Instrument: LUCI

At the sunset is clear. LUCI2 is not mounted

Summary

Night duration (12 degree el twilight) 1:40 - 12:30 UT = 10 h 50m

Observing time: 10h 20min (94%)

Weather time loss: h min (0%)

technical time loss h 40min (6%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calibrations darks LUCI1       per Giannini IRAS, FUOri, V912
Calibrations darks LUCI1       per Gargiulo
Telluric HIP93727 LUCI1 zJ 200 1" 1.17   luci1.0036-0039 per Nardini
Nardini J1712+57 LUCI1 zJ 200 1" 1.17 0.27h luci1.0048-0055 completed
Di Criescenzo AndVII LUCI1 J imaging 0.07h   for AndVII J1 completed
Di Criescenzo AndVII LUCI1 Ks imaging 0.3h   for AndVII Ks1 completed
Telluric HIP115428 LUCI1     luci1.0131-0134 for Feruglio. NOTE: first attempt acquisition saturated
Feruglio S82X _2058 LUCI1 H/G210 1"slit 3h luci1.0140-0184 seeing limited seeing <1"
Telluric Rossi Hip 20379 LUCI1 zJ 200 1"   luci1.0194-0198 DDT Rossi
DDT Rossi SN2018ibb LUCI1 zJ 200 1" 1.0h luci1.0264-0282 DDT Rossi
Standard Epifani Sa95-275 LBC UB/VRI 0.2h   DDT Epifani
DDT Epifani 1/I Borisov LBC UB/VRI 0.8h   DDT Epifani
Standard Epifani Sa95-275 LBC UB/VRI 0.2h   DDT Epifani
Calibrations Sky Flats LBC-R V_Bessel (PA=0)     DDT Epifani
Calibrations Bias LBC       DDT Epifani

Details

00:00 Calibrations
  • darks for Giannini IRAS 60.0sx1 LIR,norm luci1.0003-0007
  • darks for Giannini FUOri 5.0sx6 LIR,int luci1.0008-0012
  • darks for Giannini V912 30.0sx2 LIR,int luci1.0013-0017
  • darks for Giannini telluric 12.0s x5 LIR,int luci1.0018-0022
  • darks for Gargiulo 300.0s x5 MER norm luci1.0023-0027
  • darks for Gargiulo telluric 3.0s x5 LIR int luci1.0028-0032

01:23 Slew to telluric HIP93727 for Nardini J1712+57
  • acq luci1.0033-0035 seeing 1". Note used HeI +J filters! changed script and OT for future use
  • sci luci1.0036-0039

01:35 Slew to Nardini J1712+57
  • acq luci1.0040-0047 take three more truslit after adjusting offset
  • seeing 1.1" on guider at 01:54 0.9" on acquisition images
  • sci luci1.0048-0055
  • seeing 0.9" at 02:12 on DIMM, 0.8" on guider

02:14 Slew to Di Criscienzo AndVII J1 and Ks1
  • seeing 1" at 02:20 on DIMM
  • sci luci1.0056-0065 AND 1
  • seeing 1" at 02:30 on DIMM
  • 02:27 sci luci1.0066-0075 AND 2
  • 02:37 sci luci1.0076-0085 AND 3
  • seeing 1" on camera, 0.8" on images at 02:38
  • 02:46 sci luci1.0086-0095 AND 4
  • seeing 1.2" on DIMM, 0.8" on guiding at 02:48
  • seeing 0.6" on images, 0.8" on guiding at 02:52
  • 02:57 sci luci1.0096-0105 AND 5
  • seeing 0.6" on images, 0.8" on guiding at 03:03
  • 03:07 sci luci1.0106-0115 AND 6 image 108 with some elongation due to guiding problem
  • seeing 0.8" on guiding at 03:09

03:19 Seeing 1" on DIMM Slew to Feruglio telluric HIP115428
  • this telluric is too bright in acquisition with OH+z saturates! change script and DO AGAIN
  • acq luci1.0125-0130
  • sci luci1.0131-0134

03:58 Seeing 0.9" on DIMM Slew to Feruglio S82X _2058
  • acq luci1.0135-0139 took other tru slit after adjusting allignement
  • seeing 0.8" on DIMM at 04:10
  • sci luci1.0140-0184
  • seeing 0.6" on DIMM, 0.6" on guider at 04:25
  • RTD Aladin is slow and subtraction gets stuck half of the times. I often need to stop and start Aladin
  • seeing 0.7" on DIMM, 0.6" on guider at 04:45
  • 05:20 execute a second time
  • seeing 1" on guider at 05:20 - 1.1" on DIMM
  • seeing 0.7" on guider at 05:40 - 0.6" on DIMM
  • seeing 0.6" on guider at 06:03 - 0.5" on DIMM
  • 6:20 LUCI GUI stopped abruptly
  • 6:24 start again but another error has occurred during the execution of image 168
  • 6:30 start again
  • seeing 1.0" on DIMM, 0.7" on guider at 06:38
  • seeing 1.0" on DIMM, 0.9" on guider at 07:24

07:42 Slew to Telluric of Rossi (Hip 20379)
  • seeing 0.9" on DIMM, 1" on guider at 07:51
  • acq luci1.0185-0187
  • sci luci1.0188-0191

07:55 Slew to DDT Rossi SN2018ibb TOO EARLY take telluric again!
  • acq luci1.0192-0193
  • sci luci1.0194-0198

08:15 Slew to DDT Rossi SN2018ibb
  • error in script BUUUU wrong readout
  • acq luci1.0259-0263
  • sci luci1.0264-0272
  • not sure object is in field, added offset y -25 arcsec. Lately I checked and everything is fine.
  • seeing 1.1" on DIMM, 1.3" on guider at 08:49
  • 9:21 start again science (same script)
  • sci luci1.0273-0282
  • seeing 1.3" on guider at 09:38
  • sometimes RTD doesn't work (can not subract images)
  • seeing 0.8" on DIMM at 09:56

9:58 Change of instrument, switch to LBC

10:15 Slew to STD SA95-275 of DDT Epifani (2I/Borisov)
  • 10:20 technical problem with the ADsec
  • 10:49 technical problem resolved
  • 10:50 to STD SA95-275
  • 10:51 collimation and copointing
  • 11:03 re do collimation and copointing
  • 11:15 start acquisition on SA95-275
  • seeing 1.2" on DIMM at 11:15
  • 11:22 slew to STD SA100-267
  • 11:25 start acquisition on SA100-267

11:31 slew to 2I/Borisov (DDT Epifani)
  • 11:32 collimation
  • 11:36 start acquisition on target (U-VRI sequence 1)
  • 11:45 start acquisition on target (U-VRI sequence 2)
  • 11:53 start acquisition on target (U-VRI sequence 3)
  • seeing 1.0" on DIMM at 11:55
  • 12:01 start acquisition on target (B-VRI sequence 1)
  • 12:07 start acquisition on target (B-VRI sequence 2)
  • 12:13 start acquisition on target (B-VRI sequence 3)

12:20 slew to STD SA95-275 (DDT Epifani) * 11:22 collimation and copointing * 12:28 start acquisition on SA95-275

12:47 sky flats LBC-R V_Bessel (PA=0)
Topic revision: r7 - 25 Oct 2019, AndreaRossi
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback