-- FeliceCusano - 01 Oct 2019

INAF queue observing, 2019 Oct 01- Oct 02

Observer: F. Cusano, A. Gargiulo
Telescope Operator: S. Allanson
Support Astronomer: O. Kuhn
Instrument:

At the sunset the sky is clear. LUCI2 is not available for spectroscopy due to masks-related problems.

Summary

Night duration (12 degree el twilight) 2:00 - 12:20 UT = 10 h 20m

Observing time: 10h 10min (98%)

Weather time loss: 0h 0min (0%)

technical time loss 10min (2%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Calibrations Rossi, Di Criscienzo skyflat J LUCI1-2        
Epifani HIP83489 LUCI1 G200 zJ-HK   luci1.0045-0048 (zJ) luci1.0049-0052 (HK)  
Epifani 2015KZ120 LUCI1 G200 zJ 1h/2h luci1.0057-0068 to be checked! Very high seeing in the last 4/5 images
Epifani 2015KZ120 LUCI1 G200 HK 0.33/2h luci1.0069-0072 to be checked! Probably no good due to the high seeing
Antoniucci V350Cep MODS1-2 Dual Grating 0.33/0.33h mods1b.0001-0004 mods1r.0002-0005 mods2b.0001-0004 mods2r.0004-0007 completed
Antoniucci Feige 110 MODS1-2 Dual Grating      
Belladitta PSOJ030 MODS1-2 Red Grating 3/3h mods1r.0014-0018 mods2r.0016-0021 complete
Gargiulo HIP10185 LUCI1 G200 zJ      
Gargiulo VAN001 LUCI1 G200 zJ 2h/10h luci1.0080-0107  
Giannini HD37397 LUCI1 G210 K      
Giannini V2775Ori LUCI1 G210 K 0.5/0.5h luci1.0115-0144 completed
Calibrations Epifani flat&arc Luci1 G200 HK      
Calibrations Antoniucci flat 0.8" MODS1-2 Dual      

Details

1:25 Calibrations
  • skyflats in J band for Rossi and Di Crisicenzo luci1.0021-0030 luci2.0016-0025

1:43 we slew to Epifani program
  • 1:56 we send the script for the Epifani telluric HIP83489 (zJ, HK)
  • acq luci1.0038-0042
  • 2:05 seeing on dimm 1.16
  • sci luci1.0045-0048 (zJ)
  • sci luci1.0049-0052 (HK)

  • 2:17 we send the script for the Epifani target 2015KZ120 (zJ, HK)
  • acq luci1.0053-0056
  • 2:28 seeing on dimm 1.13"
  • 3:00 seeing on dimm 1.3"
  • 3:19 seeing on dimm 2.5"
  • 3:20 we pause the script
  • 3:27 seeing 1.4" we re-start to integrate
  • sci luci1.0057-0068 (zJ)
  • 3:40 seeing on dimm 2.0"
  • 3:51 seeing on dimm 2.0"
  • sci luci1.0069-0072 (HK)

4:06 we switch to MODS. The seeing is no good for this program or for any other LUCI program, so we switch to MODS where we have more backup programs.
  • 4:27 seeing on dimm 2.33"

4:37 we slew to the Antoniucci program V350Cep
  • 4:38 we send the script for Antoniucci target V350Cep
  • 4:38 seeing on dimm 1.95"
  • acq mods1r.20191001.0025-20191002.0001 mods2r.20191002.0001-0003
  • 4:48 seeing 1.56"
  • sci mods1b.0001-0004 mods1r.0002-0005 mods2b.0001-0004 mods2r.0004-0007

  • we send the script for the Antoniucci telluric Feige 110
  • acq mods1r.0006-0007 mods2r.0008-0009
  • sci mods1b.0005-0007 mods1r.0008-0010 mods2b.0005-0007 mods2r.0010-0012

5:48 we slew to Belladitta program PSOJ030
  • 5:50 seeing on images 1.1"
  • 5:49 seeing on dimm 0.82"
  • acq mods1r.0011-0013 mods2r.0013-0015
  • 6:10 seeing on dimm 0.84"
  • 6:23 seeing on dimm 0.90"
  • 7:08 seeing on dimm 1.31"
  • sci mods1r.0014-0018 mods2r.0016-0021

7:25 on avergae, the seeing is good. We switch to LUCI.
  • 8:02 problems with check pointing

8:18 we slew to Gargiulo program VAN001
  • 8:18 we send the script for the Gargiulo telluric HIP 10185
  • 8:24 seeing on dimm 1.14"
  • acq luci1.0073-0075
  • sci luci1.0076-0079

  • 8:29 we send the script for the Gargiulo target VAN001
  • 8:30 seeing 1.4"
  • acq luci1.0080-0083
  • 8:40 seeing on dimm 0.91". We start the integration
  • 9:01 seeing on dimm 0.95"
  • 9:16 seeing on dimm 0.73"
  • 9:33 seeing on dimm 0.65"
  • 9:42 seeing on dimm 0.64"
  • 9:46 we send the script again
  • 10:14 seeing on dimm 0.65
  • 10:34 seeing on dimm 0.93"
  • 10:38 seeing on dimm 1.17"
  • 10:42 seeing on dimm 1.14"
  • 10:46 seeing jumps from 1.1 to 1.6. check the last two images.
  • sci luci1.0084-107

10:52 we slew to Giannini program V2775Ori
  • we send the script of Giannini Telluric HD37397
  • 10:57 seein on dimm 1.44"
  • for some not clear reasons the telluric alignement is not successuful. We repeat it twice, then we decide to skip to the target and in the meanwhile fix the problem with the telluric

  • 11:05 we send the script of the Giannini target V2775Ori
  • 11:07 seeing on dimm 1.32"
  • acq luci1.0111-0114
  • 11:13 seeing on dimm 1.19"
  • 11:21 seeing on dimm 1.04"
  • 11:35 seeing on dimm 1.11"
  • 11:50 seeing on dimm 0.87"
  • sci luci1.0115-0144

  • 12:02 we send the Telluric again
  • acq luci1.0148-0150
  • 12:19 seeing on dimm 0.93"
  • sci luci1.0151-0154

Calibrations
  • Flat for Epifani G200 HK slit 1" luci1.0155-0164
  • Arc for Epifani G200 HK slit 1" luci1.0165-0170
  • Flat for Antoniucci slit 0.8" mods1b.0008-0013 mods1r.0020-0025 mods2b.0008-0013 mods2r.0022-0027
Topic revision: r7 - 27 Nov 2019, FeliceCusano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback