INAF queue observing, 2019 Sep 27-28

Observer: F. Cusano, A. Gargiulo
Telescope Operator: S. Allanson
Support Astronomer: O. Kuhn
Instrument:

Before sunset issues with MODS1-2 not coming up. At the sunset the sky is partially covered by clouds, humidity at 95%.
At 1:37 sky is clear, some low clouds all around, humidity at 63%. At 1:42 problem solved with MODS we can use them.

Summary

Night duration (12 degree el twilight) 2:00 - 12:20 UT = 10 h 20m

Observing time: 9h 55min (96%)

Weather time loss: 0h 0min (0%)

technical time loss 25*min (4%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Massi FS143 LUCI H2      
Massi G035.02 LUCI H2 2.2/2h   completed
Massi G035.02 LUCI Ks 0.16/0.16h   completed
Massi G180.20 LUCI H2 2/2h   completed
Massi G180.20 LUCI Ks 0.16/0.16h   completed
Nardini HD205840 LUCI G200/zj     completed
Nardini J223408 LUCI G200/zj 0.375/0.3h   completed
Massi FS151 LUCI H2      
Massi G097.53 LUCI H2 2/2h   completed
Massi G097.53 LUCI Ks 0.16/0.16h   completed
Nardini J0303 LUCI G200/zj 0.36/0.36h   completed
Nardini HIP13197 LUCI G200/zj     completed
Nardini J0304 LUCI G200/zj 0.46/0.46h   completed
Massi G176.25 LUCI H2 2/2h   completed
Massi G176.25 LUCI Ks 0.16/0.16h   completed
Massi FS122 LUCI H2      
Massi G168.06 LUCI Ks 0.16/0.16h   completed
Massi G168.06 LUCI H2 0.88/2h    
Massi flat LUCI H2, Ks      

Details

1:52 LUCI does not copy files in newdata directory

1:58 Problem solved

2:17 we slew to Massi program G035.02
  • 2:17 we send the script for Massi standard FS143
  • 2:20 seeing on dimm 1"

  • 2:29 we send the script for Massi target G035.02 (H2)
  • 2:30 seeing on dimm 0.9"
  • 2:50 seeing jumps to 1.6"
  • 2:53 seeing on images 0.8"
  • 3:03 seeing jumps to 1.4"
  • 3:06 seeing on guider 0.8"
  • 3:17 seeing on guider 0.8"
  • 3:33 seeing on guider 0.7"
  • 3:33 humidity rises to 90%
  • due to the variable seeing, we take two more exposures per arm
  • 3:48 humidity is 70%

  • 3:50 we send the script for Massi target G035.02 (Ks)
  • 3:51 seeing on dimm 1.0"
  • luci1.0030.fits is not good

4:03 we slew to Massi program G108.20
  • 4:03 we send the script for Massi target G108.20 (H2)
  • 4:04 seeing on dimm 0.8"
  • 4:23 seeing on dimm 0.7"
  • 4:32 humidity 54%
  • 4:49 seeing on dimm 0.83"
  • 4:45 seeing jumps to 1.4"
  • 4:58 seeing on dimm 0.98"
  • 5:18 seeing on dimm 1.10"

  • 5:20 we send the script for Massi target G108.20 (Ks)
  • 5:28 seeing on dimm 0.98"

5:29 we slew to Nardini program J223408
  • 5:30 we send the script for Nardini telluric HD205840
  • 5:32 MOS error on LUCI2
  • 5:45 MOS error solved
  • 5:45 seeing on dimm 0.85"
  • acq luci1.0060-0062 luci2.0061-0063
  • sci luci1.0063-0066 luci2.0064-0067

  • 5:52 we send the script for Nardini target J22340
  • 5:52 seeing on dimm 0.9"
  • acq luci1.0067-0070 luci2.0068-0071
  • 6:03 seeing on dimm 0.77"
  • 6:13 seeing on dimm 0.70"
  • sci luci1.0071-0075 luci2.0072-0076

6:18 we slew to Massi program G097.53
  • 6:18 we send the script for Massi standard FS151
  • 6:18 MOS error on LUCI2
  • 6:37 MOS error still persists. Dave suggested to go on with just LUCI1
  • 6:40 we send again the script just for LUCI1 we changed the script in a hurry, so PARTNER and PI_NAME keywords are wrong
  • 6:44 seeing on dimm 0.72"

  • 6:51 we send the script for Massi target G097.53 (H2)
  • 7:14 seeing on dimm 0.70"
  • 7:15 Dave puts the mask back in storage, and gives us the authorization to use LUCI2, but just for imaging. we have acquired 6 images with LUCI1 ==luci.0086-0091==
  • 7:20 we send the script again in bino mode
  • 7:24 seeing on dimm 0.72"
  • 7:38 seeing on dimm 0.76"
  • 7:55 seeing on dimm 0.67"
  • 8:10 seeing on dimm 0.70"

  • 8:20 we send the script for Massi target G097.53 (Ks)
  • 8:21 check pointing
  • 8:24 we send the script again
  • 8:34 seeing on dimm 0.70"

8:35 we slew to Nardini program J0303
  • for spectroscopy we can use just LUCI1

  • 8:37 we send the script for Nardini target J0303
  • 8:45 seeing on dimm 0.70"
  • acq luci1.0114-0117
  • 9:01 seeing on dimm 0.72"
  • 9:10 seeing on dimm 0.73"
  • sci luci1.0118-0125

  • 9:16 we send the script for Nardini telluric HP13917
  • acq luci1.0126-0128
  • sci luci1.0129-0132

9:22 we slew to Nardini program J0304
  • 9:22 seeing on dimm 0.75"
  • acq luci1.0133-0136
  • 9:32 seeing on dimm 0.85"
  • 9:45 seeing on dimm 0.76"
  • 9:59 seeing on dimm 0.75"
  • sci luci1.0137-0148

10:05 we slew to Massi program G176.25
  • 10:06 we send the script for Massi target G176.25 (H2)
  • 10:38 seeing on dimm 0.73"
  • 10:47 seeing on dimm 0.82"
  • 11:14 seeing on dimm 0.72"
  • 11:21 seeing on dimm 0.69"

  • 11:25 we send the script for Massi target G176.25 (Ks)
  • 11:33 seeing on dimm 0.85"

  • 11:33 we send the script for Massi standard FS122 (H2)
  • 11:45 seeing on dimm 0.69"

11:45 we slew to Massi program G168.06
  • 11:45 we send the script for Massi target G168.06 (Ks)
  • 11:57 we send the script for Massi target G168.06 (H2)
  • 11:57 seeing on dimm 0.87
  • 12:17 seeing on dimm 0.65

Calibration
  • dome H2/Ks flat for Massi
Topic revision: r9 - 07 Oct 2019, FeliceCusano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.