-- AndreaRossi - 03 Jun 2019

INAF queue observing, 2019 June 02 - 03

Observer: A. Rossi
Telescope Operator: S. Allanson
Support Astronomer: B. Rothberg (on call)
Instrument: LBC

At the sunset the sky is clear. We start with LBC.

Summary

Night duration (12 degree el twilight) 3:25 - 11:10 UT = 7 h 45m

Observing time: 6*h* 55min (90%)

Weather time loss: 0h 00min (0%)

technical time loss 0h *55min (10%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
calibration dark LUCI2       Bianchi
calibration skyflat LBC V, R      
Annibali R18 LBCb+r g,r 0,66/1h    
Annibali R27 LBCb+r g,r 0,33/1h   completed
Annibali R37 LBCb+r g,r 0,66/1h   completed
Annibali R42 LBCb+r g,r 0,33/1h   completed
Prandoni TGSS1530 LBCblue+red r,i 0.5/1h in r ; 0.5/1.5h in i    
Casasola telluric LUCI1+2 G210 J 0.15/0.15h luci1.20190603.0007-10; luci2.20190603.0017-20  
Casasola mask1 LUCI1+2 G210 J 0.5/5h luci1.20190603.0015-0023 completed
calibration flat LUCI1+2 z,H     Casasola

Details

1:50 starting LUCI dark for Bianchi NGC4701, 200s MER x 5
  • luci2.20190603.0002-06 200s MER x 5
  • luci2.20190603.0007-11 20sx3, LIR INT ok anche per 2XMMi

02:50 starting sky flat V R

03:05 slew to Annibali program R18 30 min loss because of several issues with collimation, 10 min loss for wrong target
  • dohybrid not enough stars in the field. create a new co-point OB
  • 03:16 dohybrid again
  • 03:30 background too high, wait more, then clear up configuration
  • 03:35 dohybrid again
  • 03:42 copointing new version.. blue looks elongated
  • 03:50not correcting for z22 on bluie, try disconnect e reconnect LBC,run dohybrid again
  • 04:02 NGC3077_1
  • 04:05 dimm 0.9", 0.8" on LBCred
  • 04:14 0.9" on LBCred
  • 04:15 andrea realize that target name is wrong and the real target is another, anyway blue is elongated, z22 does not correct.
  • 04:15 copointing on real target
  • 04:30 dofpia does not work, must use dohybrid every time
  • 04:40 lbccontrol gui crashed, connection is very slow
  • 04:41 copointing
  • 04:45 UGC8091_1
  • 04:46 seeing 0.7" on LBCred, 0.8" on LBCblue
  • 05:01 seeing 0.6" on LBCred, 0.8" on LBCblue
  • 05:13 UGC8091_2 stars are round in both channels
  • 05:19 circa, bright lines just exactly on the galaxy, asteroid or whatever,image 051420 and 051415
  • 05:20 seeing 0.6" on LBCred, 0.8" on LBCblue
  • 05:40 seeing 0.6" on LBCred, 0.7" on LBCblue

05:42 slew to Annibali program R27 OB3
  • 05:43 dofpia
  • 05:50 sending UGCA276_3
  • 05:58 seeing 0.6" on LBCred, 0.8" on LBCblue
  • 06:11 seeing 0.7" on LBCred, 0.9" on LBCblue

06:16 slew to Annibali program R37 UGC8638 OB3
  • 06:20 dofpia, first time aborted not enough star, then on a copointing field
  • 06:37 send UGC8638_3, dimm 0.8"
  • 06:40 seeing 0.6" on LBCred, 0.8" on LBCblue
  • 07:05 send UGC8638_2
  • 07:15 seeing 0.5" on LBCred, 0.8" on LBCblue
  • 07:20 circa, bright lines just exactly on the galaxy, asteroid or whatever,image 071949 and 071943. Twice in a night! this is odd

07:36 slew to Annibali program R42 UGC9240 OB3
  • 07:40 dofpia
  • 07:43 sending UGC9240_3
  • 07:47 seeing 0.6" on LBCred, 0.8" on LBCblue
  • 08:04 seeing 0.7" on LBCred, 0.9" on LBCblue

08:11 slewing to Prandoni TGSS1530
  • 08:13 dofpia
  • 08:18 sending TGSS1530_r_i_1
  • 08:22 seeing 0.6" on LBCred, 0.7" on LBCblue
  • 08:34 seeing 0.5" on LBCred, 0.7" on LBCblue
  • 08:57 seeing 0.6" on LBCred, 0.7" on LBCblue
  • 09:12 seeing 0.8" on LBCred, 0.9" on LBCblue

09:14 Switch to LUCI

09:40 slewing to Casasola telluric HIP87643
  • 09:41 15min loss LUCI2 MOS error
  • 09:56 send again
  • dimm seeing 0.9"
  • 10:05 do again acq wrong slit (the first is the one at the center! unusual?)
  • acq luci1.20190603.0004-06; luci2.20190603.0014-16
  • spec luci1.20190603.0007-10; luci2.20190603.0017-20

10:23 slewing to Casasola mask1 filter J
  • 10:25 dimm seeing 0.8"
  • 10:25 5min loss LUCI2 MOS error
  • 10:31 send again
  • 10:34 5min loss LUCI2 MOS error
  • 10:39 send again
  • 10:40 LUCI2 MOS error
  • 10:42 send LUCI 1 only script
  • acq =luci1.20190603.0011-0014 =
  • spec luci1.20190603.0015-0023
  • 10:53 dimm seeing 0.9"
  • 11:18 dimm seeing 0.9"

11:30 we close, END OF THE NIGHT
  • LUCI FLAT z H for Casasola
  • fieldstop N3.75 off on luci2, corrected
  • start again luci1.20190603.0034-43; luci2.20190603.0032-41 z band
  • luci1.20190603.0044-53; luci2.20190603.0042-51 H band

-- AndreaRossi - 03 Jun 2019
Topic revision: r7 - 07 Jun 2019, FeliceCusano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback