-- FeliceCusano - 02 Jun 2019

INAF queue observing, 2019 June 01 - 02

Observer: F. Cusano, A. Rossi
Telescope Operator: S. Allanson
Support Astronomer: O. Kuhn (on call)
Instrument: LBC

At the sunset the sky is clear. We start with LBC.

Summary

Night duration (12 degree el twilight) 3:23 - 11:11 UT = 7 h 48m

Observing time: 7h 28min (96%)

Weather time loss: 0h 0min (0%)

technical time loss h *20min (4%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
calibration dark LUCI       Casasola, Moretti, Cresci
Annibali R25 LBCblue+red g,r 1h/1h   completed
Annibali R27 LBCblue+red g,r 0.33h/1h   repeat last OB seeing too high
Annibali R42 LBCblue+red g,r 0.66/1h   last ob to be repeated for seeing>1.1
Prandoni TGSS1530 LBCblue+red g,i 0.5/1h in g ; 0.5/1.5h in i   g band completed
telluric HIP87643 LUCI1-2 G210 J 0.15/0.15h luci1.20190602.0044-47; luci2.20190602.0044-47 Casasola
Casasola mask1 LUCI1-2 G210 J 0.6/5h luci1.20190602.0052-60; luci2.20190602.0052-60 seeing variable, 1hour done but first 2x4 exposures not good

Details

1:05 starting LUCI dark for Casasola and Moretti

1:55 starting dark for Cresci

2:50 starting sky flat
  • we discovered a moth in the LBC-R, we asked the IS to remove it from the camera
  • 3:32 moth is out we are reconfiguring for LBC
  • 3:49 we are ready to use LBC

3:37 slewing to Annibali R25
  • 3:49 dohybryd
  • 4:00 copointing
  • 4:04 starting science UGC6817_1
  • 4:06 dimm seeing 0.9"
  • 4:10 seeing 0.8" on LBCred image
  • 4:31 dofpia
  • 4:38 starting science UGC6817_2
  • 4:43 seeing 0.8" on LBCred image
  • 4:58 seeing 0.9" on LBCred image
  • 5:08 dofpia x2
  • 5:11 starting science UGC6817_3
  • 5:20 seeing 0.8" on LBCred image

5:39 slewing to Annibali R27
  • 5:40 dofpia
  • sending UGCA276_2
  • dimm seeing 0.9"
  • 6:10 seeing 1.0" on image
  • 6:12 dofpia
  • 6:17 sending UGCA276_3
  • 6:37 seeing 1.0" on image
  • seeing jump last 3 images do again please

6:42 slewing to Annibali R42
  • 6:44 dofpia
  • 6:51 sending UGC9240_1
  • 7:01 dimm seeing 0.9", fwhm on images 0.8-0.9"
  • 7:17 dofpia
  • 7:22 sending UGC9240_2
  • 7:29 dimm seeing 1", fwhm on images 1"
  • 7:49 dofpia
  • 7:53 sending UGC9240_3
  • 8:03 jump in the dimm seeing to 1.2-1.3", we keep going and will take some images more, 8:12 dimm seeing back to 1"

8:22 slewing to Prandoni TGSS1530
  • 8:26 dofpia
  • 8:33 sending TGSS1530_g_i_2, dimm seeing 0.9" , 8:40 fwhm 1.3-1.4" on images, at 8:56 fwhm on images is 0.8-0.9"

9:35 we switch to LUCI

10:00 slewing to Casasola telluric HIP87643
  • 10:01 LUCI2 MOS error
  • 10:12 problem solved sending script again
  • 10:14 dimm seeing 0.9", fwhm on guider 0.8"
  • acq luci1.20190602.0041-43; luci2.20190602.0041-43
  • spec luci1.20190602.0044-47; luci2.20190602.0044-47

10:23 slewing to science of Casasola mask1 filter J
  • acq luci1.20190602.0048-51; luci2.20190602.0048-51
  • spec luci1.20190602.0052-60; luci2.20190602.0052-60
  • 10:46 seeing jumping to 1.9" ! , we wait to see if it goes down, we pause the script
  • 10:48 we start again the script seeing aroung 1.2", seeing variable now (10:56) 1.3"
  • 11:01 seeing down to 1", at the fifth exposure.
  • 11:09 seeing 1"

11:20 we close, END OF THE NIGHT
Topic revision: r13 - 07 Jun 2019, FeliceCusano