INAF queue observing, 2019 May 2-3

Observer: F. Cusano, A. Gargiulo
Telescope Operator: D. Gonzalez-Huerta
Support Astronomer: O. Kuhn
Instrument:

At the sunset the sky is fully covered by clouds, the dome is closed. We open at 5 UT. MODS is dismissed

Summary

Night duration (12 degree el twilight) 3:00 - 11:35 UT = 8 h 35m

Observing time: 6h 2*min* (71%)

Weather time loss: 2*h* 0*min* (23%)

technical time loss 0*h 33*min* (6%)

Data Summary

Project_RUN Objects Instrument Configuration ExpTime /Time_tot Images Notes
Marziani SDSSJ0958 LUCI1/LUCI2 G200-HK 1.06/0.7h luci1.0005-0012 luci2.0005-0012 completed
Marziani HIP52192 LUCI1/LUCI2 G200-HK   luci1.0016-0019 luci2.0016-0019  
Marziani SDSSJ1054 LUCI1/LUCI2 G200-HK 0.93/0.7h luci1.0023-0030 luci2.0023-0030 completed
Moretti BD86189 LUCI1/LUCI2 G200-zj/G200HK   luci1.0031-0038 luci2.0031-0038  
Moretti FKJ1244 LUCI1/LUCI2 G200-zj/G200HK 1.8/1.8h luci1.0043-0066 luci2.0043-0066 completed
Casasola HIP87643 LUCI1/LUCI2 G210-J   luci1.0070-0073 luci2.0070-0073  
Casasola magmask1 LUCI1/LUCI2 G210-J 1.55/5h luci1.0078-0091 luci2.0078-0091  
Calibration Casasola LUCI1/LUCI2 flat + arc J, flat ima J      
Calibration Moretti LUCI1/LUCI2 zjspec(luci1), HKspec(luci2)    

Details

04:55 The TO opens the dome. The sky is covered by cirrus and some clouds.

05:19 we slew to Marziani's target SDSSJ0958
  • 05:20 mos error
  • 05:24 we send the script again
  • acq luci1.20190503.0001-0004 luci2.20190503.0001-0004
  • 05:35 seeing on dimm 1.28"
  • 05:44 seeing on dimm 1.7"
  • 05:48 seeing on dimm 1.3"
  • 05:56 seeing on dimm 1.2"
  • 06:08 seeing on dimm 1.1"
  • sci luci1.0005-0012 luci2.0005-0012

06:13 we slew to Marziani's Telluric HIP52192
  • acq luci1.0013-0015 luci2.0013-0015
  • 06:21 seeing on dimm 1.25"
  • sci luci1.0016-0019 luci2.0016-0019
  • sci luci1.0013-0015 luci2.0013-0015

06:25 we slew to Marziani's target SDSSJ1054
  • acq luci1.0016-0022 luci2.0016-0022
  • 06:35 seeing on dimm 0.95"
  • 06:50 seeing on dimm 1.07"
  • 07:03 seeing on dimm 1.28"
  • sci luci1.0023-0030 luci2.0023-0030

07:10 we slew to Moretti's Telluric BD86189
  • 07:13 no guide star foumd on left side
  • 07:17 we send the script again
  • acq luci1.0031-0034 luci2.0031-0034
  • 07:24 seeing on dimm 1.22"
  • sci luci1.0031-0038 luci2.0031-0038

07:28 we slew to Mortetti's target FKJ1244
  • LUCI1 RTD has problems in subtracting images.
  • acq luci1.0039-0042 luci2.0039-0042
  • 07:40 seeing on dimm 0.97"
  • 07:55 seeing on dimm 0.8"
  • 08:19 seeing on dimm 1.0"
  • 08:40 we send the script again
  • 08:49 seeing on dimm 1.03"
  • 09:23 seeing on dimm 0.89"
  • 09:41 seeing on dimm 0.74
  • sci luci1.0043-0066 luci2.0043-0066

09:45 we slew to Casasola's Telluric HIP87643
  • acq luci1.0067-0069 luci2.0067-0069
  • 09:57 seeing on dimm 0.99"
  • sci luci1.0070-0073 luci2.0070-0073

10:00 we slew to Casasola's target magmask1
  • acq luci1.0074-0077 luci2.0074-0077
  • 10:23 seeing on dimm 1.0"
  • 10:30 collimation problem on left side. _do not use luci1.20190503.0079.fits, check luci1.20190503.0078.fits _
  • 10:50 we start again the integration
  • 11:11 seeing on dimm 1.24"
  • 11:17 collimation on left side is going out.
  • 11:21 we send the scrip again.
  • sci luci1.0078-0091 luci2.0078-0091

Calibrations
  • J images for Casasola's calibration. (skyflat) luci1.0092-0098 luci2.0092-0097
  • flush luci1.0098-0102 luci2.0098=0102
  • flat J, Halo1 luci1.0103-0107 luci2.0103-0107
  • arc Ar luci1.0108-109 luci2.0108-109
  • arc Xe luci1.0110-111 luci2.0110-111
  • imaging (dome flat) luci1.0112-116 luci2.0112-116 flush
  • during the claibration LUCI2 stuck and luci1 goes on, so it did calibration in J and H, I tart again the calibration,
  • J dome flat luci1.0132-0136 luci2.0117-0121

Moretti
  • flat and arc zjspec for LUCI1 and HKspec for LUCI2
  • luci1.0137-0141 luci2.0122-0126 flush
  • luci2.0142-0146 flat zjspec halo2, ==luci2.0127-0131==flat HKspec halo1
  • luci2.0147-0148 arc zjspec Ne, ==luci2.0132-0133==arc HKspec Ne
  • luci2.0149-0150 arc zjspec , ==luci2.0134-0135==arc HKspec Ar
  • luci2.0151-0152 arc zjspec , ==luci2.0136-0137==arc HKspec Xe
Topic revision: r7 - 30 May 2019, FeliceCusano
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki? Send feedback